                                                                                                                                               1 METER MAX.                       STAR PICKETS

                                                          PROVIDE WASH WATER FOR                                                                                               DROP INLET
                                                                                                                                                                               WITH GRATE
        TIMBER SLEEPER OR METAL                           TRUCKS EXITING SITE
        GRID 100mm HIGH AND
                                                                                                                                                                               WIRE OR STEEL MESH
        SPACED AT 300mm CTS                               MIN LE                                                                                                               (14 GAUGE x 150mm                                                                                             WRAP FILTER
                                                                NGTH
                                                                       10m                                                                                                     OPENINGS) WHERE




                                                                                                                                                                                                                                                                                                                                               500 - 600mm
                                                                                        BERM 300 HIGH MIN                                                                                                                                                                                    CLOTH OVER GRATE
                                                                                                                                                                               GEOTEXTILE IS NOT
       CONSTRUCTION SITE                                                                                                                                                       SELF-SUPPORTING
                                                                                                                                                                                  WOVEN GEOTEXTILE                                                                                                                                                                                        1.5m STAR PICKETS AT MAX.
                                                                                                EXISTING ROADWAY                                                                                                                                                                                                                                                                          2.5m CENTRES



      GEOTEXTILE FABRIC                                                                                                                                                   STAR PICKET                                                                                                                                                                                                     SELF-SUPPORTING
                                                                                                                                                                          FITTED WITH                                                                                                                                                                                                     GEOTEXTILE
                                                          50-75mm GRAVEL BED MIN                                                                                          SAFETY CAP
                                                                                                                                                                                                                                                                                                                                                                                                    FLOW
                                                          200mm THICK                                                                                                                                                                                                                                                                                                               DIRECTION OF
                          RUNOFF FROM PAD DIRECTED TO                                                                                                              WOVEN GEOTEXTILE
                                                                                                                    SANDBAGS
                          SEDIMENT TRAP
                                                                                                                                                                             RUNOFF                                                                     WRAP FILTER CLOTH
                                                                                                                                                                                                                                     RUNOFF             OVER GRATE                                                                                                                        ON SOIL, 150mm x 100mm




                                                                                                                                                FLOW
                                                                                                                                                                             WATER WITH
                   TEMPORARY CONSTRUCTION VEHICLE EXIT                                                                                                                       SEDIMENT                                                WATER WITH                                                                                                                                           TRENCH WITH COMPACTED
                                          SCALE: N.T.S.                                                             WATERWAY                                                                                                         SEDIMENT                                                                                                                                             BACKFILL AND ON ROCK, SET
                                                                                                                                                                                                                                                                                                                                                                                          INTO SURFACE CONCRETE

                                                                                                                    EXCAVATION




                                                                                                                                                                                                                                                                                                                                               600mm MIN.
                                                                                                                                                                                                                                                                           FILTERED                                                                                  SECTION DETAIL
                                                                                                                                                                                                     FILTERED
                                                                                                                                                                                                                                                                            WATER
                                                                                                                                                                                                      WATER
                                                                                                                                                                            GEOTEXTILE
                                                                                                                    EARTH BANK                                              EMBEDDED 150mm
                                                                                                                                                                            INTO GROUND                                                     GEOTEXTILE INLET FILTER TYPE B




                                                                                                                                                                                                                                                                                                                              MIN. 1.5m
                                                                                                                                                                                                                                                                                                                                                                           20m MAX.
                                                                                                                                                                                                                                                            SCALE N.T.S
                                                                                                                                                                   FOR DROP INLETS AT NON-SAG POINTS,                                                                                                                                                                                        FLOW
                                                                                                                                                                   SANDBAGS, EARTH BANK OR EXCAVATION USED
                                                                                                                                                                   TO CREATE ARTIFICIAL SAG POINT                                                                                                                                                      STAR PICKETS AT
                                                                                                                                                                                                                                                                                                                                                       MAX. 2.5m SPACINGS
                                                                                                                        GEOTEXTILE INLET FILTER CONSTRUCTION NOTES:                                                                                                                                                                                    TYPICAL

                                                                                                                        1.    FABRICATE A SEDIMENT BARRIER MADE FROM GEOTEXTILE OR STRAW BALES.

                                                                                                                        2.    PICKET SPACING TO BE A MAXIMUM 1.0m CENTRES.                                                                                                                                                                                                   PLAN

                                                                                                                        3.    IN WATERWAYS, ARTIFICIAL SAG POINTS CAN BE CREATED WITH SANDBAGS OR EARTH
                                                                                                                              BANKS AS SHOWN IN THE DRAWING.

                                                                                                                        4.    DO NOT COVER THE INLET WITH GEOTEXTILES UNLESS THE DESIGN IS ADEQUATE TO
                                                                                                                              ALLOW FOR ALL WATERS TO BYPASS IT.                                                                                                                                                                                                                    DIRECTION
                                                                                                                                                                                                                                                                                                                                                             DISTURBED                                       1.5m STAR PICKETS AT
                                                                                                                                                                                                                                                                                                                                                                                    OF FLOW
                                                                                                                                                       GEOTEXTILE INLET FILTER A                                                                                                                                                                             AREA                                            MAX. 2.5m CENTRES

                                                                                                                                                                    SCALE N.T.S



                  TIMBER SPACER TO SUIT                            KERB-SIDE INLET




                                                                                                                                                                                                                                                                                                                                                             UNDISTURBED
                                                                                                                                                                                                                                                                                                                                                             AREAS

                                                                   GRAVEL-FILLED WIRE MESH OR
                                                                   GEOTEXTILE "SAUSAGE"


                                    OVERFLOW              TIMBER SPACER
         RUNOFF                                                                                                                       GRADIENT OF
                                                          TO SUIT                                                                                                           CAN BE CONSTRUCTED       ALL BATTER GRADES
         WATER WITH                                                                                                                   DRAIN 1% TO 5%
                                                                                                                                                                            WITH OR WITHOUT          2(H):1(V) MAX.
         SEDIMENT
                                                                                                                                                                            CHANNEL                                                                                                                                      SEDIMENT FENCE CONSTRUCTION NOTES:
                                                                                                                                                                                                                                                                               STABILISE STOCKPILE SURFACE
                                                                                                                                      DIRECTION
                                                                                                                                                        OF FLOW                                                                                                                                                          1.          CONSTRUCT SEDIMENT FENCES AS CLOSE AS POSSIBLE TO BEING PARALLEL TO
                                                                                                                                                                                                                              EARTH BANK                                     2:1




                                                                                                                                                                                                                  .
                                                                                                                                                                                                                                                                                                                                     THE CONTOURS OF THE SITE, BUT WITH SMALL RETURNS AS SHOWN IN THE
                                                                                                                                                                                                                                                                  X.)




                                                                                                                                                                                                         300mm MIN
                                                                                                                                                                                                                                                                                   SL
             SEDIMENT                                                                                                                                                                                                                                         MA                     OP                                              DRAWING TO LIMIT THE CATCHMENT AREA OF ANY ONE SECTION. THE
                                                                                                                                                                                                                                                           PE(                          E(
                                                                                                                                                                                                                                     FLOW               LO                                MA                                         CATCHMENT AREA SHOULD BE SMALL ENOUGH TO LIMIT WATER FLOW IF
          GRAVEL-FILLED WIRE MESH                               FILTERED WATER                                                                                                                                                                     2:1 S                                    X.)                                      CONCENTRATED AT ONE POINT TO 50 LITRES PER SECOND IN THE DESIGN
          OR GEOTEXTILE "SAUSAGE"                                                                                                                                                                                                                                                                                                    STORM EVENT, USUALLY THE 10-YEAR EVENT.
                                                                                                                                                                                  2m MIN
                                                                                                                                           150mm MIN




                                                                                                                                                                                                                                                                                                                         2.          CUT A 150mm DEEP TRENCH ALONG THE UPSLOPE LINE OF THE FENCE FOR THE
                                                                                                                                                                  NOTE: ONLY TO BE USED AS TEMPORARY BANK                                                                  SEDIMENT FENCE
                                                                                                                                                                                                                                                                                                                                     BOTTOM OF THE FABRIC TO BE ENTRENCHED.
                                                                                                                                                                  WHERE MAXIMUM UPSLOPE LENGTH IS 80 METRES.
                   MESH & GRAVEL INLET FILTER CONSTRUCTION NOTES:
                                                                                                                                                                                                                                                                                                                         3.          DRIVE 1.5m LONG STAR PICKETS INTO GROUND AT 2.5m INTERVALS (MAX.) AT
                   1.   INSTALL FILTERS TO KERB INLETS ONLY AT SAG POINTS.                                                                                                                                                     STOCKPILE CONSTRUCTION NOTES:                                                                         THE DOWNSLOPE EDGE OF THE TRENCH. ENSURE ANY STAR PICKETS ARE
                                                                                                                                      DIVERSION DRAIN CONSTRUCTION NOTES:                                                                                                                                                            FITTED WITH SAFETY CAPS.
                   2.   FABRICATE A SLEEVE MADE FROM GEOTEXTILE OR WIRE                                                                                                                                                        1.     PLACE STOCKPILES MORE THAN 2 (PREFERABLY 5) METRES FROM EXISTING
                                                                                                                                      1.   BUILD WITH GRADIENTS BETWEEN 1% AND 5%.                                                    VEGETATION, CONCENTRATED WATER FLOW, ROADS AND HAZARD AREAS.                       4.          FIX SELF-SUPPORTING GEOTEXTILE TO THE UPSLOPE SIDE OF THE POSTS
                        MESH LONGER THAN THE LENGTH OF THE INLET PIT AND
                        FILL IT WITH 25mm TO 50mm GRAVEL.                                                                                                                                                                                                                                                                            ENSURING IT GOES TO THE BASE OF THE TRENCH. FIX THE GEOTEXTILE WITH
                                                                                                                                      2.   AVOID REMOVING TREES AND SHRUBS IF POSSIBLE - WORK AROUND THEM.                      2.    CONSTRUCT ON THE CONTOUR AS LOW, FLAT, ELONGATED MOUNDS.                                       WIRE TIES OR AS RECOMMENDED BY THE MANUFACTURER. ONLY USE
                   3.   FORM AN ELLIPTICAL CROSS-SECTION ABOUT 150mm HIGH                                                                                                                                                                                                                                                            GEOTEXTILE SPECIFICALLY PRODUCED FOR SEDIMENT FENCING. THE USE OF
                                                                                                                                      3.   ENSURE THE STRUCTURES ARE FREE OF PROJECTIONS OR OTHER                              3.     WHERE THERE IS SUFFICIENT AREA, TOPSOIL STOCKPILES SHALL BE LESS
                        x 400mm WIDE.                                                                                                                                                                                                                                                                                                SHADE CLOTH FOR THIS PURPOSE IS NOT SATISFACTORY.
                                                                                                                                           IRREGULARITIES THAT COULD IMPEDE WATER FLOW.                                               THAN 2 METRES IN HEIGHT.
                   4.   PLACE THE FILTER AT THE OPENING LEAVING AT LEAST A                                                                                                                                                                                                                                               5.           JOIN SECTIONS OF FABRIC AT A SUPPORT POST WITH A 150mm OVERLAP.
                                                                                                                                      4.   BUILD THE DRAINS WITH CIRCULAR, PARABOLIC OR TRAPEZOIDAL                             4.    WHERE THEY ARE TO BE PLACE FOR MORE THAN 10 DAYS, STABILISE
                        100mm SPACE BETWEEN IT AND THE KERB INLET. MAINTAIN                                                                CROSS-SECTIONS, NOT "V" SHAPED.
                        THE OPENING WITH SPACER BLOCKS.                                                                                                                                                                               FOLLOWING THE APPROVED ESCP OR SWMP TO REDUCE THE C-FACTOR TO                      6.          BACKFILL THE TRENCH OVER THE BASE OF THE FABRIC AND COMPACT IT
                                                                                                                                                                                                                                      LESS THAN 0.10.                                                                                THOROUGHLY OVER THE GEOTEXTILE.
                                                                                                                                      5.   ENSURE BANKS ARE PROPERLY COMPACTED TO PREVENT FAILURE.
                   5.   FORM A SEAL WITH THE KERB TO PREVENT SEDIMENT
                        BYPASSING THE FILTER.                                                                                                                                                                                  5.     CONSTRUCT EARTH BANKS ON THE UPSLOPE SIDE TO DIVERT WATER                                                                 SEDIMENT FENCE
                                                                                                                                      6.   COMPLETE PERMANENT OR TEMPORARY STABILISATION WITHIN 10 DAYS                               AROUND STOCKPILES AND SEDIMENT FENCES 1 TO 2 METRES DOWNSLOPE.
                                                                                                                                           OF CONSTRUCTION.                                                                                                                                                                                                         SCALE: N.T.S.
                   6.   SANDBAGS FILLED WITH GRAVEL CAN SUBSTITUTE FOR THE
                        MESH OR GEOTEXTILE PROVIDING THEY ARE PLACED SO                                                                                            DIVERSION DRAIN                                                                                STOCKPILES
                        THAT THEY CAN FIRMLY ABUT EACH OTHER AND                                                                                                                                                                                                        SCALE N.T.S
                        SEDIMENT-LADEN WATERS CANNOT PASS BETWEEN.                                                                                                      SCALE N.T.S

                             MESH & GRAVEL INLET FILTER
                                         SCALE N.T.S                                                                                                                                                                                                                                                                                                                                  1       0     1    2       3    4    5
                                                                                                                                                                                                                                                                                                                                                                           SCALE                                               (metres)
                                                                                                                                                                                                                                                                                                                                                                                              1 : 100 (FULL SIZE)



                                                                                                                             CLIENT DETAILS:                                                            PROJECT ADDRESS:                                                           APPROVED BY:                 PROJECT NAME:

                                                                                                                                                                                                                                                                                                                PROPOSED RESIDENTIAL DUPLEX
                                                                                                                                                                                                                                                                                                                TITLE:                                                                    STATUS:
                                                                                                                                                  IZAROX QLD PTY LTD                                                  73 SOUTHERN CROSS PARADE
                                                                                                                                                                                                                                                                                                                EROSION AND SEDIMENT                                                      FOR APPROVAL - NOT FOR
                                                                                                                                                                                                                        SUNRISE BEACH QLD 4567                                                                                                                                            CONSTRUCTION
 © ABN 89 647 469 707
                                              B     23/02/23   INFORMATION RESPONSE                    QT     JB   JB
                                                                                                                                                                                                                                                                                             NATHAN WAGSTAFF    CONTROL DETAILS
    37 MARY ST                                                                                                                                                                                                                                                                                  RPEQ: 26443
                                              A     25/10/22   FOR APPROVAL                            QT     JB   JB        SCALE:
NOOSAVILLE, QLD 4566                                                                                                                                                                                                                                                                            CPEng NER       DRAWING NUMBER:                                                           PROJECT NUMBER:                                 SHEET REV:
                                             REV     DATE                 DESCRIPTION                DWN     CHK   APP
   +61 7 5211 1003
                                                                                                                                                                   NTS                                                                                                                         DATE: 23/02/23                                                                                                                              SIZE:
RECORCONSULTING.COM                                                             REVISIONS
                                                                                                                                                       DO NOT SCALE, IF IN DOUBT ASK
                                                                                                                                                                                                                                                                                                                031                                                                       20220237                                        A1 B

Used in these records

About this file

File size
7.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - Engineering Plans.pdf · 7.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.