Original source · versioned page text
260615 Operational Works Planning Report Dowling Neylan
Attached to the e-mail OPW15/0118 Operational Works Application - Advertising Devices.
lot 1 Tingirana Noosa 25 hastings street, noosa heads NOTES: 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH TIMBER MERBAU CLADDING AS 1684.2 2010 EXISING BALCONY TO EXTENT SHOWN 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. HEIGHTS APPROXIMATE ONLY 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO TO BE CONFIRMED RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 3000 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN 2400 2100 STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 planter TO BEACH TO HASTINGS STREET GLASS FRONT DISPLAY UNIT TO EXTERNAL OF COMMON AREA STAIRWELL WALL elevation D fc finish + copper over to flash and lip over merbau cladding 35mm timber battens fixed to existing block rendered common area wall + 20mm vertical merbau cladding over callout refer to detail heights to be confirmed on site 1000 2400 shelving 2100 fc finish + feature copper required as flashing over (cabinet including glass protruding 25mm) Section 1 elevations/sections tasmanian oak timber shelving unit fixed to existing block rendered wall + glass doors over max 200 finished depth glass doors over, size to be confirmed though inclusive of overall finish Callout of Section 1 scale 1:20 PROPOSED: SHOP FRONT FINISH CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 2 of 2 DATE: ISSUE NO: + INTERNAL FITOUT DOWLING & NEYLAN ADRIAN BATISTA PH: 0403 481 474 SCALE: 1:100 JULY 15 I NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.