Original source · versioned page text
Development Application part 2 OF 2 All of CD, Information in notes - MCU12/0216
Very large file (36.8 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 303, section 1. The text section number identifies this passage in the reader.
Specific Outcomes Probable Solutions Compliance Comments
/ /NA
Buffer Area,
a) fronting the Noosa River – development is
setback a minimum of 40m from mean high
water spring or as otherwise prescribed by
the Environmental Protection Agency’s
Erosion Prone Area Maps;
b) not fronting the Noosa River – development
is located outside the riparian zone and
setback a suitable distance from the
watercourse having regard to the
development constraints of the property
and the need to protect environmental and
riparian values;
OR
S5.3 NA
For Animal husbandry on premises in the Rural
Zone—
a) stock proof fencing is installed along
watercourses at a distance of no less than
10m from the top of the bank;
b) stock watering points are located no less
than 15m away from the top of the bank of
watercourses; and
c) stock crossing points across watercourses
are defined and controlled with stock proof
fencing, to prevent stock from damaging
riparian vegetation or banks to
watercourses;
OR
S5.4 Recreational facilities (including NA
playgrounds, pergolas, barbeques etc) are
setback a minimum of 30m from the top of the
bank of a watercourse and 10m from the top of
the bank of a drainage line;
OR
December 2012 file ref.1271_DA1_310_002 37 Groundwork Plus
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.