Attachment 1 - Site Inspection Report
life well before the house. There is high likelihood that the planters will become a
regular maintenance issue as time goes on.
It was noted that the planters are installed parallel and against the building with a
clearance gap of approximately 100mm. Close inspection noted that the building
features an exposed slab edge system meaning a cold joint is present just above
ground level.
Planter boxes built close to wall
Given the construction system utilised the planter boxes were noted to limit clear
viewing of the cold joint. Furthermore, debris had begun to accumulate between the
planters and the house wall.
Page 7 of 10
ENGINEERING REPORT
Address: 2/16 Grant St, Noosa Heads
Reference: 112351