Council archive · source document
Part 16 of 37 Appendix 14 - Traffic Acoustic Report MCU12/0208
Error! Reference source not found.
28 August 2012
2
<..f) Cardno
Shaping the Future
. Locations impacted at 68dB(A)or more are considered to be affected by a level traffic noise high
enough to result in significant order of acoustic treatment (e.g. heavier laminate windows,
insulation, possibly mechanical ventilation). This contour is shown in red, however currently no
lots fall within this contour.
Options for Acoustic Barrier Treatments
A noise model with the inclusion of acoustic barriers (Figure 3, attached) was prepared as follows:
. A 2.4m high acoustic barrier screening the recreation area of the eastern site townhouse lots.
. A 2.0m high acoustic barrier on the side boundary of a north-eastern lot.
. A 2.4m high acoustic barrier on the side boundary of the western lot closest to the Site/Walter
Hay Drive roundabout.
To demonstrate the effect of screening from future dwellings in addition to the above acoustic barriers,
a row of single storey dwellings was included on the western site lots that front Walter Hay Drive.
The inclusion of acoustic barriers and future dwellings into the model has shown these options have
potential as being suitable acoustic treatments. However as future ground elevations are unavailable
(based on the sections the future road will be elevated), these barrier heights are subject to revision.
Screening from dwellings is dependent upon height (ie 1 or 2 storey) and the space between dwellings
(side boundary setback). Single storey dwellings would provide adequate screening; however to
prevent noise flanking between dwellings, side boundary setbacks for road front lots should be
minimised.
Conclusion
This preliminary analysis was conducted on the basis of the model assumptions. To conduct a thorough
road traffic noise assessment and remove ambiguity from the current analysis, the following information
would be required:
. Unattended noise monitoring of Walter Hay Drive;
. Confirmation from Council with respects to the applicable external and internal noise criteria;
.
Analysis should be based upon future ground levels (including the site and road reserve);
I hope the above is of assistance. If you should have any further queries, please do not hesitate to
contact the undersigned on (07)3877 6928.
Yours sincerely
Paul Lonard
Senior Acoustic Consultant
forCardno
K:\OO AcousticslBOOX Projects\B024 -
Noosa on Weyba\B024_51 01_LO 1 PL.docx
_
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 16 of 37 Appendix 14 - Traffic Acoustic Report MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.