NOOSA COUNCIL
APPROVED PLANS
OPW14/0178 6 MAY 2014
[OCR of page images]
Lot 10
ey,
Lot 8
wy, %,
ey
(o)*
Lot7 ®
Lot 6
AT SC1389563 - LIVE 11kV/LV
AND SERVICES. FAND EXCAVATE.
RESTORE SITE WFEN COMPLETED.
DANGER
ONLY AT THIS LOCATION.
USE BARRIER AND SIGNS.
DEVELOPERS SURVEYOR
1.
- NOTES
PROPOSED LOT 17 - S.E. CORNER NEXT TO
THE DRAINAGE RESERVE IS TO HAVE A MINIMIUM
2m x 2m TRUNCATION TO ALLOW FOR THE
INSTALLATION OF ELECTRICAL SERVICE PILLAR
CLEAR OF SWWATER AND S/WATER PITS.
THE TRUNCATED PROPERTY BOUNDARY LINE
OF VENTURE DRIVE AND PROJECT AVENUE IS
TO BE STAKED FOR NEW ELECTRICAL WORKS
INSTALLATION OF BORED CONDUITS
TO COMPLY WITH THE ELECTRICAL SAFETY ACT, BORED
CONDUITS SHALL BE INSTALLED AT A MINIMUM DEPTH
OF 900mm. AT EACH END, WHERE THE CONDUIT RISES
TOA DEPTH OF LESS THAN 900mm, A TRENCH SHALL
BE EXCAVATED AND PROTECTIVE COVERS AND MARKER
TAPE SHALL BE LAID ABOVE THE CONDUIT.
TO BE INSTALLED.
TUNNEL BORING SHALL BE REQUIRED AT
STN'S 248-28.
TELSTRA - NOTE
RELOCATION WORKS REQUIRED.
PROPOSED TO MOVE SMALL PIT TO
ALLOW FOR ELECTRICAL WORKS IN
FRONT OF PADMOUNT SC21257
DANGER
IN VENTURE DRIVE, EXISTING
MAJOR SERVICES IN ALL LOCATIONS.
CONFIRM AND POT HOLE BEFORE EXCAVATING.
DETAIL 'A'- SH
DRAINAGE
RESERVE
REINSTATE VERGE &
LANDSCAPE AS REQUIRED
ELECTRICAL CONTRACTOR
The works detailed on this drawing shall be constructed in accordance with Robin Russell & Associates’
General Specification for Installation of Electricity Reticulation and Street Lighting - Issue ‘Y’.
CIVIL CONTRACTOR
The installation of all electrical conduits shall be supervised by the holder of an electrical work licence
- Electrical Safety Act 2002.
Energex conduits and transformer site retaining walls shalt be installed strictly in accordance with
Energex's specifications (see below). They will be inspected for compliance upon completion.
The civil contractor shail install enveloping conduits under retaining walls behind pillars - two 100mm
Conduits into each lot (one for Electricity, one for Tetstra), 600mm deep behind the pillar, near ground
level inside the lot
Relevant specifications in Energex's Underground Distribution Construction Manual are found at -
Section C1: Conduits
Section C2: Excavation
Section C3: Transformer Sites
These sections of the manual can be downloaded from the following Energex web site:
hitp:/Awww.energex.com.au/about_energex/asp/echnical_documents. asp
Civil engineers who have registered for access to the following RRA website may download extracts
from Energex's manual at
ittp-/Awww. robrus.com.au
The civil contractor shall ensure that all conduits have been installed before constructing retaining
wails, paths, driveways & water services. The civil contractor shall please inform the electrical
contractor of any ‘as constructed" departures from the civil design.
Care! Lighting of new or altered existing roads might not comply with specified standards
until new road lighting has been commissioned. The civil contractor shail ensure that
Necessary warming signs are installed and speed restrictions are applied if necessary.
ON-SITE SERVICES CHECKS
Robin Russell & Associates gives no warranty regarding the presence or location of buried services,
including newly-installed services. "As Constructed” locations may differ from what is drawn on this
works plan. Contractors shall be responsible to identify and locate all buried services. Initial
identification can be obtained from:
Dial Before You Dig Service
Telephone 1100
Fax 1300 652 077
On-line enquiries can be made at:
http:/Awww.1100.com.au.
Having determined which services may be present, on-site locations should then be arranged with
relevant service authorities.
Sewerage and water plans for the subdivision may be obtained on request from the Superintendent.
INSTALLATION OF TELECOMMUNICATIONS CONDUITS BY TELSTRA
Telstra's contractor will install telecommunications conduits in shared trenches and other excavations
provided oy the electrica: contractor. in commercial subd visions. or where more than 2xP 100 conauits
are required the conduits may not be instalied aove Energex conduits. They shall be laid in a
separate trench on the standara communications alignment specified
Contractors shail novfy Telstra's contractor
* one week before road crossing trenches will be open
* — two days before footpath trenches will be cpen
Teistra’s contractors are
south of Brisbane River Silcar Communications
LEGEND: ELECTRICAL
—-—— EXISTING UNDERGROUND CABLE
PROPOSED UNDERGROUND CABLE
PROPOSED NBN CONDUIT ON COMMS ALIGNMENT
COMMS CONDUIT IN SHARED TRENCH
BORED CONDUIT
GAS IN SHARED TRENCH
STATION NUMBER
PADMOUNT TRANSFORMER
PROPOSED POLE TRANSFORMER
METER BOX/ LV SWITCHBOARD
PROPOSED SERVICE PILLAR
EXISTING SERVICE PILLAR
FUTURE SERVICE PILLAR
EXISTING LINK PILLAR
PROPOSED C&i PILLAR
EXISTING OVERHEAD ELECTRICITY MAINS
PROPOSED OVERHEAD ELECTRICITY MAINS
HV POLE
HV +LV POLE
LV or STREET LIGHT POLE
PROPOSED STREET LIGHT
EXISTING STREET LIGHT
FUTURE UNDERGROUND STREET LIGHT
RECOVER STREET LIGHT
EARTH
EXISTING RATE 3 STREETLIGHT CABLE
PROPOSED RATE 3 STREETLIGHT CABLE
EXISTING RATE 3 STREET LIGHT
PROPOSED RATE 3 STREET LIGHT
EXISTING CONSUMERS OVERHEAD CABLE
PROPOSED CONSUMERS OVERHEAD CABLE
EXISTING CONSUMERS UNDERGROUND CABLE
PROPOSED CONSUMERS UNDERGROUND CABLE
Lg PROPOSED CONSUMERS SWITCHBOARD
o EXISTING CABLE
elsewhere Service Stream Commun cations
Lot 12 © PROPOSED CABLE
| ) BIKE PATH CLEARANCES o 340mm HD CONDUIT
MOLY * . . . . " . 5 woe
¢ Xs} Lot 201 Lot 16 ‘Austroads Guide to Road Design Part 6A: Pedestrian & Cyclist Paths" specifies a minimum
REINSTATE VERGE AS | | Lot 14 / . clearance of 0.5m between a bike path and any obstacle. in order to achieve specified road © 80/100mm LD CONDUIT
REQUIRED CAUTION 4 Ooo” ots \ I path lighting within the specified verge, it has nat been possible to satisfy that requirement. © 100mm WHITE ENERGEX COMMS. CONDUIT
RECOVER LIVE LV END. / ] Lot 10 @® 125mm LD CONDUIT
eee | tot TREE PROTECTION ZONES TREE PROTECTION ZONE (TPZ) @ _CABLEMARKER POST
Oo | . . . .
unwed Lot 22 The Electrical Contractor must avoid any trenching, boring, p A _""ENERGEX ELECTRIC CABLE" MARKER PLATE
3 3s U1004619 Lot 12 or disturbance of earth inside any area covered by a 5 2
E & Ooe”" Tree Protection Zone (TPZ) within the extent of works for this foo
B r project Any exceptions ‘e ts must be approved wing by \ UNDERGROUND CABLE CERTIFICATION
R le projects’ Tree Arborist or Landscape Architect and in . i
B ( Ic Conjunction with all Local Authority's development approvals. All cables detailed on this drawing have been checked using the
y FUTURE STAGE 2 Lot 10 ©; cable locator described below and are, according to measurements
R zai SNe Refer AS 4970-2009 ‘Protection of Trees on Development Sites' taken, on the correct alignment and at correct depths below the
H / Lot 24 finished level, except as marked up. Alignments are subject to the
4 / NOTES accuracy of survey pegs present at the time of measurement.
/ 4. DANGER - EXISTING MAJOR TELSTRA AND SERVICE IN ALL AREAS.
LOT1 CHECK ALL SERVICES ONSITE AND HAND LOCATE AND IDENTIFY. Make: Model:
U71345 2. EXTRA WIDTH AND DEPTH TRENCHING MAY BE REQUIRED TO ACCOMMODATE Serial No: Date Cables Checked’)
‘ TELSTRA CONDUITS - LOCATIONS SUBJECT TO CONFIRMATION BY TELSTRA. Name of Person Who Conducted Checks
8 3. ALTERATIONS TO EXISTING SERVICES - NOTIFY CUSTOMERS OF PROPOSED ame oF rerson Wvno Wonducte! Ss:
Lot 5.0m DATE/TIME OF INTERRUPTION TO SUPPLY. Certified (signature of checker):
4, NOTE - SOME NON STANDARD ALIGNMENT AND BORED CONDUIT REQUIRED Phone No. of checker:
ON VENTURE DRIVE TO AVOID EXISTING SERVICES, LV CABLES AND VEGETATION.
fe ® 5. TELSTRA TO BE ON A SEPARATE ALIGNMENT. ROAD LIGHTING CERTIFICATE
tk ROCK WALL ON BOUNDARY a < NO JOINT USE SERVICES TRENCH IN COMMERCIAL/INDUSTRIAL SUBDIVISIONS. Within the bounds ofthis this toad lighting design & ceriied to
Oo os estate, certified
+ 6. DEVELOPERS SURVEYOR TO STAKE LOCATIONS AS PER NOTES ON MAIN PLAN. comply generally with the nominated categories of AS1158.1-1986,
s ASINZS1158.1.1:2005 and/or AS/NZS1158.3.1:2005 for luminaires
z & :
8 (— 7 Oe SENT la pi Eg rt
2 VENTURE DRIVE EXTENSION AND VISION COURT -
CATEGORY P4
TELSTRA - NOTE
SEPERATE TRENCHING IS REQUIRED
FOR TELSTRA CONCUITS IN
COMMERCIAL INDUSTRIAL SUBDIVISIONS ROAD LIGHTING MAINTENANCE SCHEDULE
This design assumes maintenance factors of 0.7 for minor road
LOT 2 lighting and 0.75 for major road lighting. These maintenance factors
are based on the following nominal maintenance schedule, which
might not necessarily be adopted by Energex.
1. Lamps shail be replaced at 36-month intervals.
CONSTRUCTION CONTACTS . ep ‘ .
Transformer site to be constructed by the Electrical Contractor, for new square series. TELECOMMUNICATIONS INFRASTRUCTURE 2. At that time, luminaires shail be cleaned, inspected & maintained.
ELECTRICAL ENGINEER PLAN VIEW -20m 0 20 40 60m For all construction details refer to Energex Underground Distribution Construction Manual - Section 4. 3. Vegetation shall be kept clear of streetlights 7
ROBIN RUSSELL & ASSOCIATES PTY LTD SCALE 1-100 a The Electrical Contractor shall arrange for a soil compaction (est to be cartied out on the transformer site and CONDUITS & PITS | to be designed by: Telstra's contractor 4. Inspection patrols and spot lamp replacement shall maintain
DESIGNER : 4: 1000 (At - NOT REDUCED provide Robin Russell and Associates with a written report of the results. If the result is: to be installed by: Telstra's contractor service availabilty at not less than 95%. ;
ANTHONY HOBBS ph: 0499 993515 : . ) © greater than 50 kPa then a concrete base stab shall be supplied and installed by the Electrical Contractor. to be owned by: Is r 5. Luminaires and lamps shalt be replaced with exact equivalents.
TRUCTI ¢ less than 50 kPa then the Electrical Contractor shall provide a pier foundation in line with the Energex TELECOMMUNICATIONS INFRASTRUCTURE _ to be provided by: el] ft Cc ¥
cons ON MANAGER Underground Construction Manual. ¥ a Z : y ,
SHANE HYDE ph: 0419 021772 The Civil Engineer and Civil Contractor shall ensure the site is level & prepared with retaining walls (ifrequired) & = [fn oreenannsnsac eet ercnroneea see saes serene
CIVIL ENGINEER safety fence (if required) in line with the requirements of the Energex Underground Distribution Construction Manual . Telstra AFR: : Robin Russell RPEQ 1546
TOD NOOSA CONSULTING ENGINEERS
oh 549 9600 NOOSA COUNCIL
- SOURCE DOCUMENTS SITE INFORMATION
SURVEYOR APPROVED PLANS DRAWING DWG. NO REV. NO. | DATE TOTAL NUMBER OF LOTS
MURRAY & ASSOCIATES PTY LTD OPW14/0178 6 MAY 2014 PROPOSED SC2069511 (STN 2) - VISION COURT CREATOR ow Mw o
JOHN CAMPBELL ph: 5441 2188 SCALE 1:200 (AT Al SIZE) TOD NOOSA CONSULTING ENGINEERS | PROPOSED WATER 06583/21 W 26/3/2008 ERTY DESCRIPTION
TELSTRA CONTRACTOR TOD NOOSA CONSULTING ENGINEERS | BASE ACAD..06583 EMAR T7ER2014 LOTS 1, 9-17 cancelling P/O LOT 81 ON SP211687
GM TOD NOOSA CONSULTING ENGINEERS | ROADWORKS & DRAINAGE | - 6583-54 1773/2014
BOB TANNER ph: 0477 708028
DATE | REV | REVISION APP. | DATE | REV | REVISION APP. | CURRENT REVISION CHANGES: RC TION SWP47.1 DESIGNED D. BUCKENHAM DESCRIPTION LOCATION DRAWING No.
s SUBDIVISION ELECTRICAL SERVICES
12608 | A _| ORIGINAL ISSUE RR Robin ZAG tre et ats, [SOuNcL —[ScRG. DRAWN —_| N OWENS ELECTRICITY RETICULATION GATEWAY RISE - NOOSAVILLE STAGE 1 -
266.08 APPROVED RR +t 4058 a, ROBIN RUSSELL NOOSAVILLE
R u Ss se | | Tet (07) 3672 5555 3 COUNCIL REF | 2007/1626 APPROVED BY | poco 1546
25.3.14 c FOR TENDER RR. Fax (07) 3672 5566 . - CUENT ENERGEX PROJECT No. SHEET No.
& ASSOCIATES PTY. LTD. Ema r@vobrus com au ceateriee UBD REF Me Gd Gye VV
CONSULTING ENGINEERS - ELECTRICAL ABN. 78.010.580 661 “ en * = GATEWAY RISE PTY LTD THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD $01 04679 1 OF 3
. DWT REV V26 - 20140225 DATE 25/03/2014 AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY. A1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
-
NOOSA COUNCIL
APPROVED PLANS
OPW14/0178 6 MAY 2014
[OCR of page images]
a NOTE AT $C1389563 (STN 1) - GATEWAY DRIVE
DANGER CONTRACTOR TO SUPPLY ALL LABELS TO ENERGEX SPECIFICATION ALL EXISTING LABEL INFORMATION & CABLE DESTINATIONS AT SC21257 GROUT | Ta ae Ee LABEL INFORMATION
& SC741343 TO BE CONFIRMED PRIOR TO ORDERING NEW LABELS. -
AT SC21257 AND PROPOSED R.M.U. HAND. TFMR gox35 | we 6 TRANSFORMER
EXCAVATE AND LOCATE ALL CONDUITS AND CABLES. AT SC1389563 (STN 1) - GATEWAY DRIVE AT X2069512 (STN 30) - VENTURE DRIVE 'SOLATOR 'SOLATOR
EXISTING SERVICES. TABEL | LABEL LETTER] TABEL TABEL TABEL | LABEL [LETTER LABEL TABEL
PREVIOUS XMISION COURTIAY CONDUITS ETC Size __ | COLOUR | SIZE LABEL INFORMATION LOCATION DESCRETION SIZE__[COLOURE SIZE LABEL INFORMATION LOCATION DESCRETON 1 8035 | we 5 EXISTING
INSTALLED ON PROJECT No. CO064046 190140 | We | 2 FRONT | IDENTIFICATION 100x40 | WB} 15 1S70 Is71 1S72 ($73 ISOLATOR | IDENTIFICATION
DESIGN
a) [EW FRONT | IOENTIICATION 80x40 | WB | 20 FRONT | pent FCATON 2 | 8035] we | 5 EXISTING
DANGER - STN 29 10040 | we | 15 S15 SF17 1S16 oe ae 10 10 10 OFF cor | came
REFER TO PREVIOUS PROJECT No. CO054045, 150x50 | Bw} 10 | VISIONCOURT | VENTUREDRIVE | VENTURE DRIVE SPARE
HAND EXCAVATE EXISTING EARTH PIT LOCATION 15ox40 | BW | 20 FRONT | permrier tion $C2069611 1S80 SC21257 1S25 SC754851 1S30 BOX _|_DESTATION
TO LOCATE AND IDENTIFY ALL CONDUITS, CABLES To TO To TO OFF woe 3 80x35 | WB 5 EXISTING
ANC EXISTING SERVICES. SAW CUT EXISTING CABLE CABLE CABLE
DRIVEWAY IF REQUIRED AFTER LOCATION OF SERVICES. 150x50 | Bw | 10 VISION COURT 150x50 | BW | 10 VISION COURT VENTURE DRIVE | VENTURE DRIVE SPARE SIDE
INSTALL THKV CABLE IN SPARE CONDUIT $C21257 02060511 1s61_} BOX _| DESTINATION $C2069511 $60 $C21257 1825 $C754851 130 wa | DESTINATION TO GATEWAY DRIVE
RESTORE THIS SITE TO EXISTING CONDITION row To TNSIDE FIT NEW FIT NEW FIT NEW 4 | 80x35 | WB] 5 LP2071827 (FIT NEW)
ON COMPLETION OF ALL WORKS. WW 240 (11) CABLE AND SERVICES LV TIE
USE BARRIERS AND SIGNS AT ALL TIMES. 2 wv 180x60 aw 10 VISION COURT SIDE DESTINATION
6660 wou) $C20695111S61_} WALL MATERIAL: GRAVOPLY Il (1.5mm) or similar
| | | EXISTING EXISTING FIT NEW
AT LP2171827 (STN 21)
AT $C2069511 (STN 2) - VISION COURT TABEL | LABET LETTER
TABEL | LABEL LETTER TARE] TABEL AT SC21257 (STN 31) - VENTURE DRIVE Sze _pOLoUR|_ Size LABEL INFORMATION
size__| coLour | size LABEL_INFORMATION LOCATION] DESCRIPTION CIRCUIT | LABEL | LABEL JLETTER TO GATEWAY DRIVE
vsoto | we | 20 caw |, RA No._| size _kowourt size LABEL INFORMATION 150x501 WB] 5 $C1389563 FIT NEW
f \ wo : ace FMR TRANSFORMER AND SERVICES
vo x
/ 7 1 OCS) seth 50x20 | BLUE W| 10 ! FRONT | pew TFIGATION ssouator | 80x36] WB) 6 SOLATOR TO VISION COURT
/ oo ne 100x40 | we | 15 NEAR | SOLATOR 150x50 | WB | 5 $C2068511 FIT NEW
pRNE / \ 1S60 SF62 ($64 ISOLATOR | IDENTIFICATION AND SERVICES
« FEEDER 1 | 60x35 | we | 5 EXISTING
genre / 3 2 @ fo \ 1040 | ew | 20 - Front | cexmiicanon| AT LP2071830 (STN 25)
/ i Ut835 TO u CABLE CABLE TO VENTURE DRIVE LP2071830/ TABEL | LABEL [LETTER
a O L eee 18x50 | BW | 10 | VENTURE DRIVE TFMR GATEWAY DRIVE | Sox | oesTmation 2 | 8035 | we] 5 PROJECT AVENUE LP1004619 FIT NEW 2x LABELS REQD Size _POLOUR| Size LABEL INFORMATION
Ure = o ~ © 2069512 1870 SC1389563 1S16 AND SERVICES TO VENTURE DRIVE 021257 /
on _ — eH TS ae TO TO INSIDE
_- = ~ 6,2, To case 150x50} WB} 5 PROJECT AVENUE LP1004619 FIT NEW
Up, teoxs0 | BW | 10 | VENTURE DRIVE GATEWAY DRIVE | sie
_ ao ~~ SN ~ ve " o0east2 670 TFMR $C1380563 Isié | wau | DESTINATION 3 | aos | we | 5 EXISTING AND SERVICES
- = ~ TO VISION COURT
a-7 XN . NL FIT NEW FIT NEW FIT NEW 150x650] WB | 5 $C2069611 FIT NEW
pos REINSTATE VERGE & 4 | e035] we} 5 XISTIN AND SERVICES
- oe LANDSCAPING AS REQUIRED SL SS. AT SC21257 (STN 31) - VENTURE DRIVE EXISTING
0 \ \ TABEL J LABEL JLETIER LABEL INFORMAT TABEL] LABEL — AT LP1004619 PROJECT AVENUE
X XN SUE OUR] SIZE ATION LOCATION! DESCRIPTION MATERIAL: GRAVOPLY 1! (1.5mm) of similar TABEC BELLE
\ NEAR | ISOLATOR size koLourl Sze LABEL INFORMATION
\ XN 100x40 | WB | 15 IS25 SF26 1S24 SOLATOR| IDENTIFICATION
N SR TO VENTURE DRIVE 8021257 /
“ X 150x40 | WB | 20 FRONT | neuTFicATION AT SC2069511 (STN 2} - VISION COURT 150x50 | WB | 5 LP2071830 FIT NEW
TO CIRCUIT | LABEL | LABEL |LETTER AND SERVICES
\ tsoso | ew | 49 | VENTURCORIVE FMR uae | oes | ee ee LABEL INFORMATION OPROET AEE
2069512 IS71 man | ooas | we | 6 TRANSFORMER 150x50} WB] 5 $C741343 FIT NEW
TO INSIDE cane (SOLATOR ISOLATOR AND SERVICES
1 VENTURE DRIVE TFMR SDE
50x60 | BW | 10 12 ISTt wan. | DESTINATION TO VENTURE DRIVE
X20696 1 | e035 {we | 5 LP2071830 / U2071832 FIT NEW 2x LABELS REQD BOARD AT - STN2
(FIT NEW) EXISTING AND SERVICES LV BOARD AT 02069511 - STN 2 SC2069511
TO GATEWAY DRIVE VISION COURT
2 | 90x35 | we} 5 LP2071827 U2071825 FIT NEW 2 x LABELS REG'D
AT SC754851 - OFF VENTURE DRIVE AND SERVICES cent core cers cera
LABEL LABEL ]LETTER LABEL LABEL TO VISION COURT
SzE__oLouR| size LABEL INFORMATION LocAnon) oESRTION 3 | sos | we | s 2060513 FIT NEW 2x LABELS REQD
100x40 | WB | 15 1S30 SF32 (S31 ISOLATOR! IDENTIFICATION DIRECT 12504 315A 315A 315A
ISOLATOR
150x40 | WB | 20 FRONT | iDENTIFICATION| 4 | eos l wel 5
TO
150x50 | BW] 10 VENTURE DRIVE TFMR CABLE CABLE ws
X2069512 IS72 -~ BOX | DESTAATION MATERIAL: GRAVOPLY Il (1.5mm) o similar seen
FIT NEW EXISTING :
$C21257 X2069512 [urse0see_] @
$C754851 EX SORA gf IN.4 WAY a ) $021257
4 seve RING MAIN UNIT
. = Pag & | 27!
is \ Wo yer Se
INSTALL 240(11) I i \
STRAIGHT JOINT visee667_] 2 a a u
‘ a s
Ne el | Ne ye EN eee
—< ale em a
DETAIL ‘A’ ——-& Sil gg "we Ue |
20 = fo ow as AP EXISTING
(SCALE 1:500) ,-—n yor Bly wey \s SL 7 uatgga04 +s
VENTURE DRIVE
t | 1 1* ® i) « y ter 1 mg, $C754851
| nm | po Sm -- =f (8) a ey |
J NX © oH 6 rca
ss ~ oR SC754851 a rn \ ® ¢ \ 1 5 f
_ sein ~ EX. 5OOKVA tL aaa | 20 é.o (az A. _ Ww
453522 | — —
a we NY ® x @) (TEMPORARY GENERATOR) (nama } ie ® o j :
f 53 & §C2069511 (OPEN) =~ ES z
/ $C13895! = OA COE = $C2069511 z/ I
EX. 500KVA 8 ¢ Xa 7
2 be
> $C 1389563 we oF Ts 5 4
\ * a. a © Ry, WCOPEN)
\ cA. é ar 15/508
/ Se /
\
/
TWT 13A \ ‘
\ CONSTRUCTION PROPOSAL PROPOSED COMMISSIONING PLAN
FUTURE STAGE 2
AT STN 30, CONFIRM ONSITE LOCATION CONCEPT ONLY AND SUBJECT TO CHANGE BY ~ :
FOR THE R.MUNIT AFTER ALL SERVICES THE ENERGEX SWITCHING COORDINATOR. N, a
HAVE BEEN LOCATED AND IDENTIFIED. OPEN 1S30 SC754851 \ FuT
5 ou INSTALL AS CLOSE AS POSSIBLE TO $C21257. & 1S 25 STN 31 & INSTALL TEMPORARY GENERATOR. \ 2mAL
INSTALL EXISTING 95(11) TO SC754851 TO THE NOTIFY CUSTOMERS OF PROPOSED SUPPLY INTERRUPTIONS. \
J NEW R.M.U N
| MU. HVILV SWITCHING AND GENERATORS REQUIRED. .
INSTALL 240(11) FROM SC21257 TO THE RMU.
1s INSTALL 240(11) FROM NEW PADMOUNT STN 2 ON COMPLETION OF ML WoRS eewrent ‘ \
Is TO THE NEW R.M.U. FOR REQUESTED ENERGEX FEEDERS TWYI3A AND TWA, \ NOTE
12 t1kV TE. w =
{ 5 INSTALL 240(11) FROM SC1389563 TO STN 2. z AAT Rew SWAY Pie OMeRS.
| = NEW SC2069511.
! ls
NOOSA COUNCIL | i
ai
APPROVED PLANS j
4 S12 Y
J a *
OPW14/0178 6 MAY 2014 v UkW SCHEMATIC eee LV SCHEMATIC
$C732430 |
TS0RVA & RMU sw | (SCALE 1:2500)
| (SCALE 1:2000}
\
DATE | REV | REVISION APP. DATE | REV | REVISION APP. | CURRENT REVISION CHANGES: Seen CATION SWP47.1 DESIGNED D. BUCKENHAM DESCRIPTION LOCATION DRAWING No.
. SUBDIVISION ELECTRICAL SERVICES
126.08 | A | ORIGINAL ISSUE RR. Ro b l n 2046 Bebarra Street. aestlog COUNCIL SCRC. DRAWN N. OWENS ELECTRICAL SCHEMATICS GATEWAY RISE . NOOSAVILLE STAGE 1
mame | 8 | wenove0 aR canoes a 4 NOOSAVILLE "
* R usse | | Tet (07 3872 5555 3 COUNCIL REF | 2007/1626 APPROVED BY | ROBIN RUSSELL
253.14 FOR TENDER RR Fac (07) 3872 5565 * - CUENT ENERGEX PROJECT No. SHEET No.
& ASSOCIATES PTY. LTD. Ema [email protected] centiriee REF Map Gid | SIGNED V7
venrann cont Se fo we [ON GATEWAY RISE PTY LTD $0104679 2* 3
CONSUL TING ENGINEERS - ELECTRICAL LN. 78 010 589 66 oe THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
TING ABN " DWT REV 26 - 20140225 DATE 25/03/2014 AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY. A1
Page 3
-
NOOSA COUNCIL
APPROVED PLANS
OPW14/0178 6 MAY 2014
[OCR of page images]
URD CONDUIT SCHEDULE - ROADWAYS - BY CIVIL CONTRACTOR
EQUIPMENT SCHEDULE - TFMR , RMU & 11kV JOINT
‘) _X-SECTION (m) STN COMP
CONDUIT LENGTH (m) LOCATION No, | SMELD. | EX | REC] IN SIZE & DESCRIPTION iD cusc | aTy REMARKS
STATIONS PVC CABLE praw | KERB TRENCH —
LOCATION POM TO PROTECTION | EXCAV/ | TRENCH ROPE MARK REMARKS BY CIVIL GATEWAY DRIVE 1 $C1389663 | EX IN |240{11) TEMR TERMINATION 1CFCO524XLG | 1 [TO SPARE IS16
° 40mm 100mm 125mm ENERGEX (m) TAPE | DETAIL e IN |240(LV) TEMR TERMINATION LVPT4C240 1 |REFIT TOCCT4 & STN 22
Hp |N°} ip JNO} yp |No oD VENTURE DRIVE Ey] $C21257_ | Ex IN [240(11) TEMA TERMINATION 1iscTi24oT [1 [REFIT TO1S25 & NEW RMU UNIT
VISION COURT 2 | sc2060511 IN. [UNICULVERT FOUNDATION 1 |BASE SLAB REQUIRED
CRETE CAP CONDUITS IN {S00KVA TFMR CCF $21660 1
VISION COURT PMT 2) 14 2a |2|/ 24 | 2 2x24 24 N 104 OVER SW DUE TO 24.
INSUFFICIENT COVER IN’ HV. FUSE DSHVFSSLK | 1
IN |LVFUSE DSLVF31 3
VENTURE DRIVE 17 | 18A 5 1| 2 [2] 2 [eo 2x24 24 NZ 110 24 in. [11k TFMA ‘TERMINATION sorstazan | 2
24 26 29 2 29 2 2x29 116 29 iN ]LV TFMR TERMINATION LVPT 4G240 3
IN. |EARTHING COMMON pssGPoMeG | 1
TOTAL 5 154 154 154 nN 330 7 IN |EARTHING MIXTURE $ 17322 4
IN |SIGN DSRMSIGN 1
NOTES iN [CABLE PROTECTION STRIPS CIVBF 10A 6 |INSTALL OVER CABLES AT FRONT OF PMT
1. ROAD CROSSING CONDUITS SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE ENERGEX UNDERGROUND DISTRIBUTION CONSTRUCTION (UDC) MANUAL. VENTURE DRIVE 2a | 2069510 IN. [240(11) STRAIGHT JOINT 118T24/24% | 1 |RECORD LOCATION
2. ROAD CROSSING CONDUITS SHALL HAVE A MINIMUM COVER OF 800mm AT ALL PLACES UNDER THE ROAD, EXCEPT UNDER STATE-CONTROLLED “MAIN" ROADS, IN {CONCRETE PROTECTION SLAB 1352 1
WHERE CONDUITS SHALL HAVE A MINIMUM COVER OF 1200mm. IN| {CABLE PROTECTION STRIPS CVBF-A0A | 2
3. CONDUITS SHALL EXTEND TO WITHIN 900mm OF PROPERTY ALIGNMENT: PVC PROTECTIVE COVER STRIPS SHALL BE LAID ABOVE ALL ROAD-CROSSING CONDUITS IN_ {CABLE MARKER PLATE 1350-2 4
FOR THEIR FULL LENGTH. 30 X2069512 IN |UNICULVERT FOUNDATION 1 |REFER TO ENERGEX DRAWINGS LOST-D-CV009-05.
4. REFER ENERGEX UDC MANUAL V.5 SECT. C2 FOR CROSS-SECTION DETAILS. iN oq) rerwinaron “ ue 1CCF9524XLG REIT To: gay Tosorsest sans
5. BRASS "E* MARKERS SHALL BE INSTALLED IN KERBS DIRECTLY ABOVE ELECTRICITY CONDUITS. in [240(11) TERMINATION iscrpmosoaxe| 2
6, CAUTION: DO NOT CONSTRUCT RETAINING WALLS, CONCRETE PATHS OR WATER SERVICES UNTIL FOOTPATH CONDUITS HAVE BEEN INSTALLED. in. [EAATHING psardcas | 4
IN [EARTHING DSRME GT 1
URD CONDUIT SCHEDULE - BORE & FOOTPATHS - BY ELECTRICAL CONTRACTOR IN |SUPPORT CHANNELS S18434 3
IN| {BOLTS $00184 6
X-SECTION (m) | IN_ [NUTS $10885 6
CONDUIT LENGTH (m) NOTE
STATIONS PVG CABLE KERB TUNNEL 4 PR
LOCATION Fi TO ENERGEX] PROTECTION | EXcAW/ | TRENCH | MARK REMARKS Bone. | TRENCH 1. PROPOSED RMU SITE ON VERGE ADJACENT TO EXISTING PADMOUNT SC21257 IS TO BE CONFIRMED ONSITE AFTER ALL SERVICES HAVE BEEN LOCATED AND HAND POT HOLED TO IDENTIFY.
10M - 40mm No 100mm No 125mm No} 100mm (m) TAPE | DETAIL | ©
i a ee ee Co EQUIPMENT SCHEDULE - SERVICE PILLARS
Ms
VISION COURT PaT2| 3A we J2| w |e 18 N 18
14 15 30 | 2] 30 | 2 30 N JOIN TO X/RAD 30 STN COMP
LOCATION SITE 1D. EX | REC | IN SIZE AND DESCRIPTION cusc | ary REMARKS
15 15L 4 1 4 2 4 2 4 zZ 4 NO. 1.0.
PéT2| 24 es |2|/ 6 | 2 66 N 66 VISION COURT 3 2068513 in [2WAY, Si & MEN LVSP176 | 1 |CCT4LOT2
PILLAR TRENCH 1037-1 1 |(SA_FUSE 1043-1)
-gf position| | 1 10 10 ° 3L, 18 10 15 | 2071820 in. [2 WAY, St & MEN ivsPa6 | 1 |ccT2
1011-2 1
CONCRETE CAP CONDUITS 23 | _u2071621 IN |2WaY Lvsp176 | 1 {COT1.LOT 1
OVER SW CROSSING VERGE
VENTURE DRIVE 1SL 7 2,2) 7 2 7 N CNR OF LOT 9. APPROX. 1000mm 72 VENTURE DRIVE 16 | Up07ie22 In. 2 WAY, Si @ SL FUSE LvsP176 | 1
COVER, 1043-1 1
16 TEL 4 7 a a 5 4 17 | 2071823 IN [SWAY LVSP9-6 1
GATEWAY DRIVE i8A 18 3 7 a tele le 3 7 JOINTO.X/RD 3 GATEWAY DRIVE 18 | Us07tee4 in [2 WAY, S1 & S/L FUSE LvsPi76 | 1 {LOT 14
1043-1 1
18 | 19A we j2)| 7% 12 #6 N 76 79 | U2071625 iy | WAY & MEN LvsPi76 | 1 [Lot 12/13
17 | PMT 1 6 |2{ 6 | 2 60 N DANGER AT STN 1 60 1037-1 1
VENTURE DRIVE 26 26L 2a «| 1 | 28 | 2| 28 | 2 28 Z 28 20 | U2071826 IN. |2WAY LvsPi76 | 1 LOT!
26L 27 30 |2| 30 | 2 30 N 30 21 | LP2071827 In. [2 WAY LINK & MEN LVSP14-6SL | 1 |(OPEN LINKS)
1037-1 1
BDY 26 4 1 4 4 Oo 4
DANGERTIVE LV END GAP IN 22 | 2071828 In. SWAY LVSP9-6 1 |AT SC1389563 CCT4 AND
24 24h 1w |2| w |2 16 N VICINITY OF STN 24 16 LY TIE
NON STANDARD ON 3.0m POLE VENTURE DRIVE 24 U2071829 IN |3 WAY LVSP946 1 TOTALS
24A 25L 12 1 12 12 F ALIGNMENT. JOIN TO BORE 12 25 LP2071830 IN 2 WAY LINK & MEN LVSP14-6SL 1 (OPEN LINKS) LVSP4-6x 1
CONDUIT. 1037-1 1 jLV TIE TO SC21257 LVSP9-6x 3
25 4 1 a a D HAND INSTALL SA. CONDUIT a 26 | 2071831 IN. |2WAY LVSP176 | 1 |(SA FUSE 1043-1)LOT 17 Lysptaes x 2
BORE CONDUIT ON 3.an POLE 27 | 2071832 in. [tT WAY & MEN tvsPi76 | 1 Lvsei76x 8
a | 28 50 | 1 20 20 ALIGNMENT. BORE ROADWAY & | 30 20 1037-4 1 4040-1x 6
TRENCH FOOTPATHS. 24A | Uaeseez9 | EX | REC LIVE LV END CAP RECOVER CABLE BACK TO
HAND LOCATE EXISTING NEW PILLAR STN 26 fonex 4
28 28A 5 1 5 5 F CONDUIT - DANGER LIVE LV 5 1097-1x 5
JOINT AND CABLES PROTECTION BOLLARDS 1350-1 2 |ATSTN 26 1950-1x 2
VARIOS STREETS CABLE MARKER PLATES 1350-2 12 [AS SHOWN 4350-2x 12
28
ALL STREETS ul pore. PVC COVER STRIP AT PILLARS te5mm LV LUGS $06266 8 _JATSIN 17 & 20 Soeee6 x 8
TOTAL 62 816 883 87 467 30 467 UNDERGROUND CABLE SCHEDULE
1 CABLE SIZE / TYPE
ENERGEX TOTAL LOCATION Sew ry [VOLTS] Ex | REC | IN vkV LV REMARKS
NOTES 11AT240XSH] 11CT 185XSH]LVA4240XPV) LVC470XH |LVC416xPV] LVC24PVPV ] $0718!
1. CONDUITS SHALL BE INSTALLED WITHIN A CORRIDOR 300-900mm FROM PROPERTY ALIGNMENT, IN ACCORDANCE WITH ENERGEX UNDERGROUND DISTRIBUTION GATEWAY DRIVE - VISION COURT | PMT1 | PMT2 | 11kV IN 210
CONSTRUCTION (UDC) MANUAL. VISION COURT - VENTURE DRIVE | PMT 2] JT 2A | 11kV IN 90
2. FOOTPATH CONDUITS SHALL HAVE MINIMUM 750mm COVER, , REGARDLESS OF ENERGEX'S REQUIREMENTS. VENTURE DRIVE aT 2a] 30 | 11kV IN 216
3. CONNECT EXISTING CONDUITS, INCLUDING ROAD CROSSING CONDUITS, TO NEW FOOTPATH CONDUITS 30 31 | 1kV IN 20
4. TELECOMMUNICATION CONDUITS SHALL BE INSTALLED IN A SEPARATE TRENCH. JOINT USE NOT PERMITTED BY ENERGEX IN A C &1 DEVELOPMENT. VISION COURT PmT2| 3 LV IN 6 CCT 3
5. DIRECTIONAL BORING FOR ELECTRICAL CONDUIT SHALL COMPLY WITH WITH ENERGEX SWP 61.1 - TRENCHLESS TECHNOLOGY. MINIMUM COVER SHALL BE 900mm. PMT 2| 15 LV IN 62 CCT 2
OTHERWISE INSTALL PVC COVER STRIP ABOVE CONDUIT. PMT 2 24 LV IN 79 CCT 1
VENTURE DRIVE 15 17 Lv IN 84
STREET LIGHT SCHEDULE - RATE 2 7 | 2 | W IN 16 |185mm SINGLE STRAND
N POLE OR COMPONENTS OUTREACH BRACKET MOUNT 24 25 wv IN 30
s 24 27 U IN 4
LOCATION SITE 1.D. COMP |EXIST} REC ;ERECT| POLE COMP RECOVER ERECT EXIST] REC | ERECT REMARKS
No.
io. | am | am | om | type | CSC | ALIGN [TR | EXIST TO tcusthantemn Vous) CYSS Pom | om | am | CSC | Tim GATEWAY DRIVE 17 19 LV IN 89
VISION COURT a P2071893 P01 55 BPM {SLM872-4 0.7 su s7ae SUNC | SLM817-3 1.5 |StLM815-1 7.5 MINOR FOUNDATION 20 22 Lv IN 76 LV TIE
+5L P2071838 POT 55 BPM {SLM872-4 0.7 SL1 s70Le SUNC | SLM817-3 15 |SLM815-1 7.5 MINOR FOUNDATION PMT 1 22 LV IN 6 LV TIE
VENTURE DRIVE 16L P2071839 POT 55 BPM 'SLM872-4 0.7 Sui S702 SUNC | SLM8173 15 {StMg15-1 7.5 MINOR FOUNDATION
tea. | Pao7ied0 | P01 55 | BPM [SLM872-4 07 | Sut s7o.e | suNc | SLM817-3 1.5 _|SLM815-1 7.5 [MINOR FOUNDATION TOTALS ALL STREETS AT PILLARS Ly > 2
25L P2071841 POo1 55 BPM |SLM872-4 0.7 SLi S70L2 SUNC | SLM817-3 1.5 |SLM81S-1 7.5 MINOR FOUNDATION —— STREETLIGHTS SL > 99
SLM872-4 x 6
26L P207 1842 Pol §5 BPM 'SiM872-4 0.7 SLi s7a2 SUNC | SLM817-3 15 |SLM81S-1 7.5 MINOR FOUNDATION
NOTES SLM817-3 x 6 SUB-TOTAL 536 526 22 99 16
1, CHECK CLEAR WITH ALL SERVICE S BEFORE EXCAVATING. SLMB15-1 x 6
2. HAND POT HOLE AND LOCATE SERVICES AS REQUIRED. $04434 x 6 VARIANCE 4% 22 22 1 4 1
3. STANDARD STREET LIGHT POLES TO MATCH THE EXISTING IN GATEWAY DRIVE - 5.5m POLES AND 1.5m OUTREACH. NOOSA co U NCI L § 15505 x t
APPROVED PLANS TOTAL 558 548 23 103 7 OOTRENCH 544m
OPW14/0178 6 MAY 2014 NOTES:
1. THE CONTRACTOR SHALL MEASURE ACTUAL CABLE LENGTHS REQUIRED, AFTER INSTALLATION OF CONDUITS, THEN ORDER CABLE ACCORDINGLY.
2. ELECTRICAL CONTRACTOR TO IDENTIFY AND SPIKE CABLES.
DATE | REV | REVISION APP. DATE | REV | REVISION APP. | CURRENT REVISION CHANGES: Seen ATION SWP47.1 DESIGNED D. BUCKENHAM DESCRIPTION LOCATION DRAWING No.
s SUBDIVISION ELECTRICAL SERVICES
126.08 | A | ORIGINAL ISSUE RR. Ro bi n 2046 Bebarra Street Alen, COUNCIL S.CRC. DRAWN N. OWENS ELECTRICAL SCHEDULES GATEWAY RISE . NOOSAVILLE STAGE 1 .
266.08 APPROVED RR. ne nae 7 ROBIN RUSSELL NOOSAVILLE
R u Ss se | | Tek (07) 3872 5555 3 COUNCIL REF | 2007/1626 APPROVED BY | porg 4
253.14 | C | FORTENDER RR. Faxc (07) 3872 5566 . 546 CLIENT ENERGEX PROJECT No. SHEET No.
& ASSOCIATES PTY. LTD. Emait mérotrus.comau centifies UBD REF Map Gad SIGNED .
common SALTS se Me Reve) ype way RISE PTY LTD $0104679 393
ONSUL TING ENGINEERS - ELECTRICAL “ee THIS DOCUMENT (S COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
CONSULTING ELEC ABN TEO10 SH St DWT REV v26- 20140225 ‘| DATE 25103/2014 AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY. Al
Used in these records
APPROVED PLANS - OPW14/178Related documentApplication case desk ↗
About this file
- File size
- 709 KB (small file)
- File type
No other editions are linked here.