1730AppendixB
ENERGY EFFICIENCY
TO MEET MINIMUM 6 STARS BERS RATING Scale 1:100
1 0 1 2 3 4 5m
GENERAL NOTES
· CONFIRM ALL DIMENSIONS ON SITE TO EXISTING
RESIDENCE PRIOR TO COMMENCEMENT OF ANY
WORK.
· SUPPLY & INSTALL 'BIFLEX CHEMICAL TERMITE
TREATMENT (UNLESS OTHERWISE APPROVED) TO
COMPLY WITH AS3660.1 AND MANUFACTURER'S
SPECIFICATIONS
· ALL BRICKWORK (INCLUDING BRICK VENEER),
SHALL BE IN ACCORDANCE WITH AS3700-
MASONRY CODE existing laundry annex to be demolished
· ALL TIMBER FRAMING SHALL BE IN ACCORDANCE
WITH AS1684. - UNLESS OTHERWISE APPROVED
ROOF FRAMING SHALL BE OF TRADITIONAL FRAMED
CONSTRUCTION.
· FOR ALL STRUCTURAL MEMBERS, FOOTINGS & existing kitchen niche to be removed
LOAD BARING WALLS REFER TO STRUCTURAL
DOCUMENTATION PREPARED BY ENGINEERS.
· ELECTRICIAN TO SUPPLY AND INSTALL APPROVED
HARDWIRED SMOKE ALARMS IN ACCORDANCE
WITH AS3786 (NEW LOCATIONS TO BE INDICATED enclosed bedroom annex to be
SD)
· ALL ELECTRICAL WORK TO BE CARRIED OUT IN
demolished from main structure
ACCORDANCE WITH AS3000.
· ALL PLUMBING & DRAINAGE WORK TO BE CARRIED
OUT IN ACCORDANCE WITH AS3500.
DEMOLITION NOTES (AS APPLICABLE)
· CAP OFF EXISTING PLUMBING AND ELECTRICAL
WORKS AS NECESSARY BY CERTIFIED
TRADESPERSON.
subfloor setout
· MATERIALS REMOVED FROM SITE MUST BE
(indicative)
DISPOSED OF AS PER COUNCIL REGULATIONS. existing timber & concrete steps
· INVESTIGATON SHOULD BE UNDERTAKEN BEFORE
ALL WORKS THAT REQUIRES EXCAVATION. to entry to be removed
· DEMOLITION WORK TO BE CARRIED OUT AS PER
WHS REGULATORY REQUIREMENTS
FLOOR PLAN NOTES existing concrete pillars
• APPLIANCES/FURNITURE (NOT FIXED) ARE NOT to be removed (mix of concrete pillars & concrete block pillars)
INCLUDED WITHIN BUILD CONTRACT UNLESS
OTHERWISE SPECIFIED
• ALL PLUMBING FIXTURES TO BE WELS RATED
• DOOR FRAME HEIGHTS INT. 2090 EXT. 2135
• BULKHEAD MAY BE REQUIRED TO ACCOMMODATE existing hot water unit
SERVICES AND STRUCTURAL DESIGN. FINAL
LOCATION & SIZE TO BE DETERMINED ON SITE.
• PROVIDE ADDITIONAL NOGGINGS @ 1200mm FOR HW
HWS
TOWEL RAIL & 800mm FOR TOILET ROLL HOLDER
WHERE APPLICABLE.
timber bearers
M/B
existing electrical meter box
S-01
NOTES
• APPLIANCES/FURNITURE (NOT FIXED) ARE NOT
INCLUDED WITHIN BUILD CONTRACT UNLESS
OTHERWISE SPECIFIED
• ALL PLUMBING FIXTURES TO BE WELS RATED
• DOOR FRAME HEIGHTS INT. 2090 EXT. 2135
NOTE: Job No.
GROUND FLOOR - EXISTING / DEMOLITION PLAN NORTH
AD21-002
antoniajayne Design ALL DESIGN, CONSTRUCTION & MATERIALS TO BE IN ACCORDANCE WITH:
•THE NATIONAL CONSTRUCTION CODE (NCC)
•THE BUILDING CODE OF AUSTRALIA (BCA)
Issue DEVELOPMENT APPROVAL
0409 366 854 •THE QUEENSLAND DEVELOPMENT CODE (QDC)
Rev 04
•BUILDING REGULATIONS & LOCAL GOVERNMENT PLANS & POLICIES
North Booval QLD 4304
[email protected]
•CURRENT ISSUES OF AUSTRALIAN STANDARDS
•CURRENT MANUFACTUERER'S SPECIFICATIONS & INSTALLATION DETAILS AD21-001_13RECTORYSTREET Kate Mayne & Kent Mayne Date 28/10/21
FOR MATERIALS USED
www.ajdesigndp.com ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE NOTED
Page No. A.02
QBCC: 15133061 FOR APPROVAL 13 Rectory Street Pomona QLD 4568
Scale @ A3 1:100
Copyright: This drawings remains the property of antoniajayne Design and is provided for use as noted the recipient(s) of this document is/
are prohibited from disclosing such information, ideas and concepts to any person without prior written consent of the copyright holder. /Users/antoniajayne/Library/Mobile Documents/com~apple~CloudDocs/OBRIEN & DOYLE GROUP_ICLOUD/ANTONIAJAYNEDESIGN_ICLOUD/JOBS/AD21-001_13RECTORYSTREET/ARCHICAD/AD21-001_13RECTORYSTREET.pln Prepared by ANTONIA O'BRIEN
See the original