Council archive · source document
RFI - proposal plans 6 may 22 · MCU21/0212
Plans and drawings: the text below has words only, no drawings.
Very large file (30.2 MB): may take a few minutes to open.
A B C D E F G site details
E
2450 2760 4990
30 00 60 and 66 S eav iew Tce,
30 00
LO T 4 S unshine B each Q LD 4567
36000
0
0
00
0
00
0
R P189884
00
E
0
00
35
0
00
34
00
33
0
32
00
31
Lot 96 on RP 81810
30
29
an nel
public walkway S ite A rea 576 sqm
E
a n d ch
site boundary | 24.635 m approx | 94° 20' 40"
areas
te ke rb
0
00
E
36
c on c re
proposed new dw elling
2.0m setback
low er ground
internal 178.70 m ²
1 se
site boundary | 22.183 m approx | 4° 20' 40"
external - pav 26.40 m ²
S
external - pool 23.15 m ²
k
LO T 51 sub total 228.25 m ²
cos tal set bac
LO T 69
RP 81810
RP 81810
S
ground floor
6660
proposed 2 internal 259.93 m ²
Terrace
story dwelling external 26.90 m ²
site bo un da
external - pav 27.19 m ²
S
sub total 314.02 m ²
ry | 22 .34
2 level 01
S
Seav iew
internal 12.15 m ²
8 m ap pro
3220
external 78.25 m ²
sub total 89.75 m ²
S
x | 17 7° 21'
3 subtotal internal 450.78 m ²
subtotal external 181.89 m²
50"
S
proposed new
total 632.67 m²
6580
driveway
site cover
S
proposed new
storm water m ax 40% = 230.43 m ²
connection
Sw Sw Sw Sw
low er ground 219.6 m ² / 38.12%
S
0
4 E
3400
proposed new
E
sewer connection
2.0m setback ground floor 230.16 m ² / 39.95%
level 01 29.8 m ² / 5.17%
10 .5m coa
S S S S S S S S S S S S S S S S S S S S S S S
E
E sewer pum p out line
S
elec pillar
E proposed electrical site boundary | 27.345 m approx | 274° 20' 40"
2.0m setback
sta l se tba ck
connection to new dwelling
0
0
E
00
00
E
elec
30
31
E
E E E E E
notes
S
E power pole
EE E
LO T 68
E
E
RP 81810 1. All work s to be carried out in
E
00
0
0
0
0
00
00
00
FFL 35.750
00
accordance with the general
330
E
28
27
29
S
32
E roof ridge approx construction notes on cov ersheet of this
E
package.
2. All work s to be carried out in
accordance with the D A and B A
including drawings & conditions.
3. Areas m easured to outside face of
walls. E xternal c ov ered area
calculations do not include ex ternal
areas under eav es, driv eway and
uncov ered hardscaping.
legend
S S S S
existing sewer line
Sw Sw Sw Sw
existing storm water line
E E E E
existing electrical line
T T T T
existing telephone
W W W W
existing water line
note: refer s urv ey for all existing serv ices
DRAWN REV DATE ISSUE PROJECT CLIEN T DR AW ING N AM E PHASE DW G NO R EV PRO JECT NO 0375
DL
LM
D
E
16.11.21
29.03.22
DA submission
Revised DA
66 Seaview Tce, G & C Deane site plan SD 100.00 G SC ALE As
indicated
proposed site plan
LM F 1.04.22 Revised DA
Sunshine Beach
LM G 6.05.22 DA RFI schem atic design
D o not scale from draw ings. D imensions are to be checked on site prior to com m encem ent of w ork. Discrepancies to be brought to the attention of the author. A ny dim ensions not nominated m ust be referred to the A rchitect for confirma tion. The concepts and inform ation contained in this docum ent are the copyright of Architect. U se or copying of the docum ent in w hole or in part w ithout the w ritten permission of the A rchitect constitutes an infringem ent of copyright.
1:1 @ A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - proposal plans 6 may 22.pdfRelated documentApplication case desk ↗
About this file
- File size
- 30.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.