Original PDF page 7, section 2. The text section number identifies this passage in the reader.
43
X
45
E 5. PROVIDE 1.00m LONG TRANSITION OF PROPOSED FOOTPATH TO EXISTING FOOTPATH.
3
E PROPOSED FOOTPATH TO MATCH EXISTING FOOTPATH WIDTH.
N12
N7 N12
N7 N19
N6 N10 N20
N9 N10 N9 N10 6. PROPOSED 2m WIDE FOOTPATH REFER TO NOOSA COUNCIL STD DRAWING RS-065 FOR
DETAILS.
7. PROPOSED SAWCUT ALIGNMENT. REFER DETAIL SHEET C6.01.
8. PROPOSED RAMP AND TACTILES REFER TO NOOSA STD DWG SD:9006 AND ARCHITECTS
DWG FOR DETAILS.
9. PROPOSED 100mm TOPSOIL AND TURF TO REPLACE EXISTING CROSS OVERS. REFER TO
LANDSCAPE ARCHITECTS DETAILS.
10. PROPOSED BARRIER KERB AND CHANNEL TO REPLACE EXISTING CROSS OVERS. ENSURE
JOIN NEATLY INTO EXISTING KERB AND PAVEMENT.
11. EXISTING SIGN TO BE RELOCATED REFER TO SHEET C5.02 FOR DETAILS.
12. EXISTING SERVICES TO BE RAISED\LOWERED TO JOIN NEATLY INOT SURROUNDING AREA.
13. EXISTING CROSSOVERS TO BE REMOVED AND VERGE TO BE REINSTATED AS PER NOOSA
COUNCIL STANDARD VERGE PROFILE.
ENGINEER'S CERTIFICATION
This drawing has been assigned an electronic code that
signifies the drawing has been checked and approved by:
NAME: SHANE SUFFOLK
RPEQ No: 9330
SIGNED:
NOTE: 0 4 8 12m
1. ALL BATTERS TO BE 1 IN 4 U.N.O.
2. ALL BATTER STEEPTER THAN 1:4 TO BE STABILIZED SCALE 1:200 @ A1
AS PER GEOTECHNICAL ENGINEERS SPECIFICATIONS
C COPYRIGHT of this design and plan is the property of ACOR Consultants (Qld) Pty Ltd, ACN 126 011 087 ABN 18 126 011 087, all rights reserved. It must not be used, modified, reproduced or
FOR INFORMATION
copied wholly or in part without written permission from ACOR Consultants (Qld) Pty Ltd. ACOR Consultants is a trademark licensed to ACOR Consultants (Qld) Pty Ltd by ACOR Consultants Pty Ltd.
Client ARCHITECT Project Drawing Title
ACOR Consultants (Qld) Pty Ltd EXTERNAL SITEWORKS PLAN
North
LEVEL 4, 43 PEEL STR
South Brisbane QLD 4101
PROPOSED BP SERVICE CENTRE
A RFI ISSUE 26/08/20 BVZ SS T +61 7 3844 5900 NOOSAVILLE Drawn Date Scale A1 Q.A. Check Date
P1 FOR INFORMATION - BVZ SS BVZ MAR 2020 51 SCALE SS -
Issue Description Date Drawn Approved MARY STR & WEYBA ROAD Designed Project No. Dwg. No. Issue
ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS NOOSAVILLE, QLD 4566 BVZ BR190571 C3.02 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.