Original source · versioned page text
BR190571 - Civil Set
The original of this document is very large (11.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 12, section 1. The text section number identifies this passage in the reader.
LEGEND
PROPOSED SIGN
N1 REFER NOTE 1 FOR DETAILS
LEGEND
LONGITUDINAL LINES WIDTH (mm)
LANE LINES (LL)
EDGE LINES (EL) 150
1m 3m 1m 3m 1m 3m 1m
B B CONTINUITY LINES (CL) 200
600mm STRIPE AND GAP
B TURN LINES (TL) 100
B
B
GIVE WAY TRANSVERSE LINES
(SL)
B TO STOP LINES 300
600mm STRIPE AND GAP
B
PEDESTRIANS GIVE WAY LINES (GL) 300
B
1m 300 1m 300 1m
B CROSSWALK LINE (CWL) 150
PARKING BAY LINES 90
B B B B B B B B B B B B B B B B B B B B B B
REFER MUTCD PART
BICYCLE PAVEMENT
9 FIGURE 2.2 FOR
SYMBOLS
DIMENSIONS
REFER MUTCD PART
ARROW PAVEMENT 2 FIGURE 4.10, 4.11
SYMBOLS AND 4.12 FOR
DIMENSIONS
GIVE WAY GIVE WAY
TO TO
PEDESTRIANS PEDESTRIANS NOTES
1. ALL REDUNDANT LINEMARKING TO BE REMOVED.
2. INSTALL ALL SIGNS AND LINEMARKING IN ACCORDANCE WITH MUTCD.
3. PROVIDE RRPM'S TO ALL LINEMARKING IN ACCORDANCE WITH MUTCD.
4. INSTALL DISABILITY ACCESS SIGNS AND LINEMARKING IN ACCORDANCE WITH AS 2890.6.
REFER DETAIL SHEET C6.01
5. STANDARD CAR PARKING BAY SHALL BE 5400 LONG x 2600 WIDE UNLESS NOTED
OTHERWISE.
6. EXISTING SIGN TO BE RELOCATED.
1.50m 7. EXISTING LINEMARKING TO REMAIN.
8. SHOULDER PROVIDE UNMARKED PARKING SPACES.
9. PROPOSED RELOCATED SIGN LOCATION IN ACCORDANCE WITH MUTCD.
N9 N6 24.68m
GIVE WAY
TO
N8
PEDESTRIANS N7
NO NO
ENTRY ENTRY
ENGINEER'S CERTIFICATION
This drawing has been assigned an electronic code that
signifies the drawing has been checked and approved by:
NAME: SHANE SUFFOLK
RPEQ No: 9330
SIGNED:
0 4 8 12 m
SCALE 1:200 @ A1
C COPYRIGHT of this design and plan is the property of ACOR Consultants (Qld) Pty Ltd, ACN 126 011 087 ABN 18 126 011 087, all rights reserved. It must not be used, modified, reproduced or
FOR INFORMATION
copied wholly or in part without written permission from ACOR Consultants (Qld) Pty Ltd. ACOR Consultants is a trademark licensed to ACOR Consultants (Qld) Pty Ltd by ACOR Consultants Pty Ltd.
Client ARCHITECT Project Drawing Title
ACOR Consultants (Qld) Pty Ltd SIGN AND LINEMARKING PLAN
North WESSEL PETROLEUM LEVEL 4, 43 PEEL STR
PROPOSED BP SERVICE CENTRE
South Brisbane QLD 4101
A RFI ISSUE 26/08/20 BVZ SS T +61 7 3844 5900 NOOSAVILLE Drawn Date Scale A1 Q.A. Check Date
P1 FOR INFORMATION - BVZ SS BVZ MAR 2020 51 SCALE SS -
Issue Description Date Drawn Approved MARY STR & WEYBA ROAD Designed Project No. Dwg. No. Issue
PHONE : PHONE : ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS NOOSAVILLE, QLD 4566 BVZ BR190571 C5.02 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.