Original source · versioned page text
BR190571 - Civil Set
The original of this document is very large (11.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 6, section 2. The text section number identifies this passage in the reader.
00
96
7
85 EXISTING TELECOMMUNICATIONS
.9
.7
P1
1.
P1
P1
EX
.
X
79 WS
N10 E
1
EXISTING FENCE
4
.9
63
8
8
4
60
40
76
74
86
79
.8
.8
.7
X
.
.
.
EXISTING SERVICE TO BE MADE REDUNDANT AND REMOVED
P1
P1
P1
P1
P1
P1
57
1.8
4 5 2 6
85
5 EX
68 69
EXP1.
EX
1.70 .7
5
. . 1.
2
X1
1. 667
X1 1
1.
1
17
.6
P#
X
67
EX
72
61
E E
P1
.7
E 1.60
.
1
8
P1
P1
1.50
1.40
NOTES
1. AREAS TO BE LANDSCAPED IN ACCORDANCE WITH THE LANDSCAPE ARCHITECTS PLANS.
2. GRADE LANDSCAPE AREA AT MAX 1V:3H (UNO).
3. GRADE LANDSCAPED AREAS TO DRAIN TO SURFACE INLET PITS.
4. GENERAL CARPARK AND INTERNAL LINEMARKING TO ARCHITECTS DETAILS.
5. REFER ELECTRICAL, HYDRAULIC & LANDSCAPE DRAWINGS FOR CONDUIT LOCATIONS.
3
PIPEWORK TO BE INSTALLED PRIOR TO PAVEMENT CONSTRUCTION.
C3.0
3
A
C3.0
B
6. PROPOSED FOOTPATH TO MATCH NEATLY INTO EXISTING FOOTPATH
7. PROPOSED FUEL TANK VENTS - REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS
8. PROPOSED FUEL TANKS - REFER ARCHITECTS PLANS FOR DWGS
9. PROPOSED ELECTRICAL EASEMENT - REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS
10. PROPOSED 6m SEWER EASEMENT - REFER TO SEWER RETICULATION DWG C7.01 - C7.05
FOR DETAILS
11. PROPOSED GAS CYLINDER EXCHANGE - REFER TO ARCHITECTURAL DRAWINGS FOR
DETAILS
12. PROPOSED ENVIROTANK REFER ENVIROTANK DWG 1119/90/P01
13. PROPOSED FUEL POINT. REFER FUEL ENGINEERS DRAWINGS.
14. PROPOSED 2 X 10 000L ABOVE GROUND RAINWATER TANKS - REFER HYDRAULIC
DRAWINGS FOR DETAILS.
15. PROPOSED BIKE RACKS REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS
ENGINEER'S CERTIFICATION
This drawing has been assigned an electronic code that
signifies the drawing has been checked and approved by:
NAME: SHANE SUFFOLK
RPEQ No: 9330
SIGNED:
NOTE: 0 4 8 12m
1. ALL BATTERS TO BE 1 IN 4 U.N.O.
2. ALL BATTER STEEPTER THAN 1:4 TO BE STABILIZED SCALE 1:200 @ A1
AS PER GEOTECHNICAL ENGINEERS SPECIFICATIONS
C COPYRIGHT of this design and plan is the property of ACOR Consultants (Qld) Pty Ltd, ACN 126 011 087 ABN 18 126 011 087, all rights reserved. It must not be used, modified, reproduced or
FOR APPROVAL
copied wholly or in part without written permission from ACOR Consultants (Qld) Pty Ltd. ACOR Consultants is a trademark licensed to ACOR Consultants (Qld) Pty Ltd by ACOR Consultants Pty Ltd.
Client ARCHITECT Project Drawing Title
C RFI ISSUE 26/08/20 BVZ SS ACOR Consultants (Qld) Pty Ltd SITEWORKS PLAN
B FOR APPROVAL 30/06/20 BVZ SS North
LEVEL 4, 43 PEEL STR
A FOR INFORMATION 26/06/20 BVZ SS South Brisbane QLD 4101
PROPOSED BP SERVICE CENTRE
P2 FOR INFORMATION 27/03/20 BVZ SS T +61 7 3844 5900 NOOSAVILLE Drawn Date Scale A1 Q.A. Check Date
P1 FOR INFORMATION - BVZ SS BVZ MAR 2020 1:200 SS -
Issue Description Date Drawn Approved MARY STR & WEYBA ROAD Designed Project No. Dwg. No. Issue
ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS NOOSAVILLE, QLD 4566 BVZ BR190571 C3.01 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.