Bushfire risk assessment risk management plan 199 Maximillian Road Noosa North Shore Revision 1 - November 2019 · MCU20/0087

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                      Ecological Natural Area Management


7.4                 Assessment of fuel loads
Australian Standard AS3959 allows for the use of two fuel loads for assessing Bushfire Attack
Levels for bushfire attacks from open forest and woodland vegetation communities. The two fuel
loads allow for worst-case scenarios for woodland and open forest vegetation associations.
Table 6: Surface and total fuel loads for use in AS3959 Method 2 assessments of BALs
AS3959 vegetation descriptor                                  Surface fuel load                 Total fuel load
                             Forest                                25 t/ha                            35 t/ha
                            Woodland                               15 t/ha                            25 t/ha

Notwithstanding the names of the two fuel loads are “woodland” and “forest”, the names are
AS3959 descriptors for fuel loads and do not relate to the Specht vegetation formation names of
open forest and woodland.
The reasons that the two fuel loads are specified instead of allowing the consultant to input any fuel
loads based on an assessment of the extent vegetation is to ensure that the fuel loads used reflect
the maximum potential fuel accumulation and to allow for a worst case scenario. An assessment of
the fuel loads in the extant vegetation could potentially be less than the maximum fuel accumulation
if the assessment is conducted after vegetation management works such as prescribed burning.
Figure 15 below shows fuel accumulation curves for open forests in eastern Australia which indicate
that none exceeds 20 t/ha maximum fuel accumulation.


                   30
Fuel load (t/ha)




                   20


                   10


                   0
                   30
Fuel load (t/ha)




                   20


                   10


                   0
                        0     5         10          15        20     30   0       5     10         15         20        30
                                      Time since fire (years)                         Time since fire (years)

Figure 14: Fuel accumulation curves for open forests in eastern Australia




Bushfire Risk Assessment and Management Plan for a house at 199 Maximillian Road, Noosa North Shore             November 2019

                                                                     21

Used in these records

About this file

File size
5.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Bushfire risk assessment risk management plan 199 Maximillian Road Noosa North Shore Revision 1 - November 2019.pdf · 5.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.