08/0989 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132008.989
Ken Hicks & Associates
4.3.2 Residential Uses Code
For All Residential Uses
Specific Outcomes
Electricity supply infrastructure
O1 The development does not
adversely impact on existing or
future electricity supply
infrastructure;
AND
02 All uses and works maintain an
adequate safe distance from
electrical infrastructure including
substations, overhead powerlines,
power poles and transformers.
edged ex) (ere idea}
ers)
$1.1 No solution provided
$2.1 Development for uses
adjacent to or within 50m of an
existing electricity substation
incorporates noise attenuation
measures to mitigate noise
impacts;
AND
$2.2 Buildings and structures
{including swimming pools, sheds,
tennis courts or outbuildings) are
not constructed under overhead
electricity transmission lines, or
within electricity easements;
AND
$2.3 A minimum separation
distance is maintained from the
electricity transmission line to the
closest boundary of habitable
buildings and child activity areas,
as follows—
20m for transmission lines up to
132kV;
30m for transmission lines
between 133kV and 275kV; and
40m for transmission lines greater
than 275kV.
April 2008
Proposal
The development will not
negatively impact on existing electrical
infrastructure. The site is not located
within 50m of an electricity substation or
under overhead electricity transmission
lines or within electricity easements,
it 14.53 Environmentatly Sustainable
Hot Water Systems
Q3 Hot water systems are installed
and operated to support the efficient
use of natural resources and
minimise consequent pollution such
as greenhouse gas emissions.
$3.1 All hot water systems
installed are— solar systems; or
electric heat pump systems; or
natural gas or LPG systems; or any
combination of a), b) or c).
Building Design =i EES Sa |
Complies — The building wil implement
hot water systems as prescribed by the
applicable probable solution.
Water supply and conservation
04 On-site water storage is designed
and operated to support the efficient
use of water;
AND
OS On-site water storage is
adequate for occupants every day
use and fire fighting purposes.
$4.1 If in a designated rainwater
tank area as identified in Map 1 of
Schedule 8, residential uses that
qualify as class 1A or 1B structures
under the Building Code of
Australia have a rainwater tank or
tanks in accordance with Schedule
8.
AND
$5.1 Where not in a water service
area a rainwater tank of a
minimum of 60,000 litres is
provided for each dwelling unit,
with the exception of Multiple
Housing Type 1.
Complies - The proposal is identified in
Map 1 of schedule 8 as being within a
rainwater tank area. A rainwater
harvesting tank will be provided in
accordance with schedule 8.
Erosion and sediment controt
O6 Development does not cause
erosion or result in transport of
sediments off-site.
No solution provided.
Advisory Note
Persons undertaking development,
including building work, are
required under the Environmental
Protection (Water) Policy 1997
{EPP) to ensure that sediment and
Complies — The appropriate measures
will be taken during the construction
stage and beyond to eliminate erosion
and the transportation of sediments from
site.
Town Planning Report
Material Change of Use — Multiple Housing Type 2 (Duplex)
18 Sunseeker Close, Noosaville
14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0989 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.