Town Planning Assessment Report

of 28

Page text shows just the words. Original shows the document exactly as it was published.

Medium Impact Industry Zone Code
Performance Outcomes            Acceptable Outcomes               Compliance
Caretaker’s accommodation       No acceptable outcome             PO5 - Complies
PO5                             provided                          The proposal provides a single
Development for caretaker’s                                       caretaker accommodation
accommodation:                                                    unit for the site within
a) is directly associated with                                    Tenancy 9. The unit single
   and subordinate to                                             bedroom has a gross floor
   the industry activity                                          area of 64m2. The caretaker
   on site;                                                       unit will allow for 24hr
b) demonstrates a demand                                          surveillance of the building,
   for 24 hour care of                                            which will assist with crime
   buildings, operations, plant                                   prevention and management
   or equipment;                                                  of the building.
c) is not separately let for
   other accommodation
   activities;
d) includes no more than
   one caretaker’s
   accommodation per site;
e) is on a site with an area of
   at least 2,000m2;
f) has a maximum gross floor
   area of 65m2 and
g) is occupied by at least one
   person who is employed
   by the primary non-
   residential use on-site.

Height                          AO8.1                             AO8.1 - Complies
PO8                             Buildings and structures are no   The proposed development
Buildings and other             more than 10 metres in building   has a maximum height of
structures—                     height.                           approximately 8.15m.

a) are low rise and have a      AO8.2                             AO8.2 - Complies
   visual bulk and              Where excavation is required,     The proposed development
   architectural scale          the maximum portion of the        will not involve excavation.
   consistent with structures   exposed external façade of
   on adjoining and nearby      the building cannot exceed 10
   land;                        metres in building height.
b) have a maximum building
   height of two storeys;
c) do not visually dominate
   the street or surrounding
   spaces;
d) preserve the amenity of
   surrounding residential
   development including



                                                                                      Page 12 of 28
Log in to download the original file

Town Planning Assessment Report.pdf · 4.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.