Council archive · source document
Cover Letter_05-08-2019 · 132005.1133.11
BRISBANE | SUNSHINE COAST | CENTRAL QLD KON-TIKI BUSINESS CENTRE TOWER 1, LEVEL 2, SUITE T1.209, 55 PLAZA PARADE, MAROOCHYDORE QLD 4558 JFP URBAN CONSULTANTS PTY LTD ABN 79 050 414 045 5 August 2019 Job Ref: M2652/F Noosa Council By Email: <[email protected]> Att: Patrick Murphy – Coordinator Planning Re: Generally in Accordance Request – Development Approval for Material Change of Use – 140 Multiple Dwelling Units and Associated Facilities – Shop, Restaurant, Multi-Function Room and Gym over land at 75 Resort Drive, Noosa Heads (Precinct F) and described as Lot 7 on SP178340 (formerly Lot 3 on SP221524) - Council Ref: 132005.1133.9 Dear Patrick, On behalf of our client, Altum Constructions Pty Ltd, we hereby request confirmation that the attached plans are Generally in Accordance with the approved plans. The plans have been updated to include revised RL’s to take into account additional height for the lift overruns. Below is a list of the amended plans: DRAWING NO. ISSUE DRAWING NAME DATE 7038-DA08 14 Site Section 01-08-19 7038-DA23 12 Block 2 Elevations 01-08-19 7038-DA30 04 CTS100,700 & 800 Roof Plan 01-08-19 7038-DA31 03 CTS300 & 500 Roof Plan 01-08-19 7038-DA33 04 Block 4 Elevations 01-08-19 7038-DA34 04 Block 4 Elevations 05-08-19 7038-DA35 05 Block 5 Elevations 05-08-19 7038-DA36 05 Block 5 Elevations 01-08-19 7038-DA37 03 Block 4 Elevations 01-08-19 7038-DA38 03 Block 4 Elevations 01-08-19 7038-DA100 05 Block 2 Sections 01-08-19 It is understood that during the detailed building design phase, that the project’s Builders changed the lift for Blocks 2-6. The new lift design has resulted in an additional circa 500mm overrun compared to the original RL’s that were outlined on the approved plans of development. The lift overrun height limit still conforms with the maximum height limits for Blocks 2-6 and is a consequence of the detailed Building Works for the project. Please refer to the below comparison table:- Block Top of Lift RL’s (Approved Plans of Top of Lift RL’s (Generally in Height difference Development) Accordance Request) Block 2 29.770 30.360 590mm Block 3 26.510 27.005 495mm Block 4 26.510 27.025 515mm Block 5 26.510 27.022 512mm Block 6 26.510 27.010 500mm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
A GIA is necessary due to condition 9 of the Decision Notice for Noosa Parkridge, which states:
A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate lodged with Council
at completion of work for each stage confirming compliance with the maximum RL’s shown for each building on the
approved plans of development.
Could you please provide payment advice for Council’s assessment fee in the amount of $616.00 for the Generally
in Accordance to allow our client to make direct payment.
Should you require any further information, please contact our office on (07) 5450 3900.
Yours faithfully,
ALLISON DRABSCH
Senior Urban Planner
JFP URBAN CONSULTANTS PTY LTD
Encl:
Amended Architectural Drawings prepared by Blackburne Jackson Design
cc: Altum Constructions Pty Ltd
JFP Ref: M2652/F Page 2