Council archive · source document
DTMR - Concurrence Agency Response - OPW12/0139
SCRC CORRESPONDENCE
"
111111
80540914
~Queensland
~~Government
File no: 215/01663
P15833-MOM
P15976-MOM
OPW 12/0139
C/c Attn: Denis Shaw
Sunshine Coast Regional Council $CS 1154 MJ’
Locked Bag 72
Sunshine Coast Mail Centre Qld 4560
IBox: ......~.1.3.c3... R:~.~......J
’~re.)( -Coastr.. (-r Cq’l"1s
OPIAJ ’~/OI3i
For your information.
2, .
’d’
t1
"0
Jo:Je/:J ~
111:J . .~
:J1J:Jg
?-crptain Richard C Johnson i
I.
,1r-]
’
s II
Regional Harbour Master (Brisbane) \ \
c
.
~.
10 September 2012
’’-._
Department of Transport and Main Roads
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
~Queensland
~,\Government
10 September 2012 Department of
Transport and Main Roads
Attn: Wade Batty
Noosa Group Pty Ltd
PO Box 1804
Noosaville Qld 4566
Dear Sir
Tidal Works -
Request for comments -
Jetties, Piles and Pontoons at 186 Gympie Terrace,
Noosaville (Lot 162 CP907407).
Thank you for your letter of28 August 2012 about your application to complete the construction of
jetties, piles and pontoons at the location mentioned above.
As a concurrence agency under the Sustainable Planning Act 2009 and Coastal Protection
Management Act 1995, Maritime Safety Queensland has no objection to the proposal provided the
following navigation and marine safety conditions are addressed.
1. The construction must comply with UPL dwgs: 162.01.09 162.01.10 162.04.01 162.05.01,
attached to your letter dated 28 August 2012.
2. No part of the structure or any ship berthed at this structure is to extend beyond the lease area
boundary or impinge upon the 13.5m width common fairway, indicated on plan UPL 162.06.10.
3. The maximum length of all vessels utilising the common Fairway situated between lots 162 and
161 is limited to 9 m length.
4. You, or your agent, must issue any notices the Harbour Master requires.
5.
You must adequately light the structure. The contractor must position all lighting so it does not
cause a risk to the safe navigation of other vessels. Any freestanding piles must have retro-
reflective tape fitted.
6. You, or your agent, must remove any obstructions and debris encountered during construction,
and dispose of them, as the Harbour Master requires.
Department of Transport and Main Roads Our ref 215/01663 P15833-MOM P15976-MOM
Maritime Safety Queensland Your ref
Marine Operations (Brisbane) Enquiries Glenn Hale
MacArthur Avenue East Telephone +61738603556
Pinkenba Queensland 4008 Facsimile +61 738603571
Website www.msq.qld.gov.au
Email [email protected]
Page 3
7. Any ships and equipment you or your agent use must comply with the Transport Operations
(MarineSafety) Act 1994,the Transport Operations (Marine Safety) Regulation 2004 and the
Transport Operations (MarinePollution)Act 1995.
8. Any ships using this facility must comply with the Transport Operations (MarineSafety)Act
1994 and the Transport Operations (Marine Safety) Regulation 2004.
9. The contractor must complete construction within two years from the date of approval. If
construction is not completed, you will need additional or amended comments from the Regional
Harbour Master.
Maritime Safety Queensland does not need to be further consulted if all of the above conditions are
met.
A copy of this letter has been sent to the assessment manager.
Yours sincerely
~ Captain Richard C Johnson
Regional Harbour Master (Brisbane)
Page 2 of2