Skip to the record
Mmm.. taste the original NoosaWatch™

Original source · versioned page text

MCU22/0201 Application For Material Change Of Use For Car Wash And Food & Drink Outlet At 34 Elm Street, Cooroy (Deferred From General Committee Meeting Dated 12 August 2024 Item 5.1) · Attachment 2 - MCU22/0201 - Proposal Plans

of 11

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
2° Colorbond roof sheeting & eaves Dotted areas indicate Concrete gutter to Super Bays. 9) panels with painted finish to upper Sr wash bay areas, typical. bod rr rr Numbers indicate colour type of the 5° Colorbond corrugated roof sheeting & Ip Or, «$e 7) Fascia Service material, refer Color Schedule. 1 gutters, with feature beam. channel. Service Beam(6 ‘Timber battens fixed to F.C. clad Timber battens fixed to F.C. clad channel. fascia trusses at end of roof, typ. fascia trusses, typical. Super Bay MUU LE ppp, Li LLLOLELOLIIIT) (4 Fascia S) (5 Dog Wash ao Column CLL Driveway Driveway tH oe OH anne a\o & %, On Hs shy sity iy HH ATTA ie Il Oy On ie sh its Hai ne sf NGL ------------—--7+ en NGL. —--—---—-—--- - + - — = = = see & Dog Wash unit & Pool Intermal Bay Sump Pit. Cleanboard wall panels (or similar) a fixed to lower level of conc panels. fencing surround. Dashed line indicates approx. location of the existing surface level. Solid dark line indicates finished floor or finished pavement levels. SECTION (A) SUPER BAY 2 + VAC BAY STRUCTURE Cantilevered roof area to have Hardieflex panel (or similar) Services channel. ‘Numbers indicate colour type of the Colorbond ceiling lining where finish to fascia truss with timber material, refer Color Schedule. proud of the fascia truss. battens fixed to front, typical. 2° roof slope. ® utter cs} ——— ——r+— ——_—_= 10) Fascia Wash 5) ( Column g Bay 2 Driveway Driveway Solid dark line indicates finished %, NS floor or finished pavement levels. UT ie — NGL-------—-------- ——— —NGL Internal Bay Sump Pit. Cleanboard wall panels (or similar) Dashed line indicates approx. fixed to internal walls of Auto Bays, location of the existing surface level. typical. SECTION () SELF-SERVE BAY 2 12° Colorbond corrugated roof. (9) sheeting & gutters. 1 1)Gutter 4 1)Gutter DS\TDR =p Vending canopy area to have Roof canopy over Vending Colorbond ceiling lining. area to be sloped at 5°. 40 Step ladder & suitable 450 Plant & handrailing. Hardieflex panel (or similar) g Service channel. finish to fascia truss with timber Mezzanine Roof canopy over battens fixed to front, typical. rr a Concrete slab. Storage x Plant Room Entry Qty — ~FFL 112.88 \ Try) 3 door, slope 5°. Gutter rn in | nn i \ Qo) (& 5) Cots Cols S) Vending Secure WC Store Plant \ Store Room Room Driveway Area Driveway , FFL 109.95 FFL 109.95 FFL 109.95 | FAL e aie warn ay atemaiaatae i a ce ia oR en NGL NGL---- Jt Solid dark line indicates finished Dashed line indicates approx. floor or finished pavement levels. location of the existing surface level SECTION ( C ) PLANT ROOM + SECURE STORE Ceiling sheeting mounted 12° root slope. to ceiling purlins. utter Service channel. Gate Auto Bay entry canopy area to Roof canopy over Auto Wash a) have Colorbond ceiling lining. is entry to be sloped at 5° Gutter 12° Colorbond corrugated roof Hardieflex panel (or similar) @) © (9) 5° roof slope. & gutters to lower level roof, finish to fascia truss with timber with ceiling under, typical. 6 fi battens fixed to front, typical. (er— x... ] Sa or Fascia {SS Sef Gutter Horizontal timber battens fixed if cp oie ao ir If Vac Bay 1/2 to F.C. clad fascia trusses, Take Away Entry It + 3] © (5 typical Fascia a Food ink it Column Canopy It if Driveway ' I | 8 Column % if x _& Driveway a , IL & Naas Na IN a 7 %& ————— Be NGL a ee __-_____-_------ 2 ae — —-----—------- See -------- Vacuum Bay unit. NGL ——— aoments Bi eas aaa Re nant as eS Solid dark line indicates finished Cleanboard wall panels (or similar) & fixed to internal walls of Auto Bays, Dashed line indicates approx. floor or finished pavement levels. typical location of the existing surface level. SECTION @) TAKE AWAY BUILDING, AUTO BAY 2 + VAC BAY 1+2 J rite Bicing Design Group 2008 po © Design Copyright AT: These drawings may not be copied in whole ISSUED FOR PLANNING APPROVAL 34 (LOT 4, 5 & 6) ELM STREET ee ee es ee ‘or in part without the written consent of TMC NOT TO BE USED FOR CONSTRUCTION PURPOSES PROPOSED CAR WASH + 42 Building Design Group. Any changes COOROY, QLD, 4563 De eeeemenmam is 0-12-2023 | proposed by the Client, Council or the Design TMC | Building Design Group TAKE AWAY FOOD & DRINK P.O. Box 3494, Mornington, VIC, 3931. Phone No. 0416 114 573 Te [rie nsos ames resa | era | relevant Planning Approval Authority shall be reported to TMC Building Design Group FOR CHRIS KING & JOANNE HILL Matters E:mail- Ste Teo cos] @tmcdesign.com.au = Issued For DA Planning Approval Ea authorisation prior to said changes being OUTLET Scale: 1:100 (A1) Date: Date: DEC 2023 _| 2023 implemented ‘The peak body for the Draw Designed building design profession TC 20 Dec 2023 10:35 PM - T:\TMC\\2020\20-032 Chris King- Cooroy, QLD\20-032 DA Rev F.DWG T. MICHAELS T. MICHAELS Sheet No: 7 of 9. ——- ee a
Log in to download the original file

ATTACHMENT 2 - MCU22_0201 - PROPOSAL PLANS.pdf · 9.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.