Appendix 3 - Bicycle Parking

Attached to the e-mail MCU17/0524 - Information Response.

of 1

Page text shows just the words. Original shows the document exactly as it was published.

               SMOKE DETECTORS                                                                                                                                                                                                                                PROTECTION OF OPENABLE WINDOWS
               To comply with AS 3786-2014 and the
                                                                                                                                                                   GATEWAY DRIVE
                                                                                                                                                                                                                                                              Protection of openable windows to be in compliance
               Building Fire Safety (Domestic Smoke
                                                                                                                                                                                                                                                              with Part 3.9.2.5, Vol 2 of the NCC. A window opening
               Alarms) Legislation Amendment                                                                                                         200                 6000                    200
                                                                                                                                                                                                                                                              must be provided with protection, if the floor below the
               Regulation 2016 - smoke alarms.                                                                                                                                                                                                                window in a bedroom is 2m or more above the surface
               Approved smoke detectors with mains                                                                                                                                                                                                            beneath (Unless the lowest level of the window opening
               supplied power and battery backup.                                                                                                                                                                                                             is more than 1.7m above the finished floor level).
               Smoke alarms must be installed on each
               storey:




                                                                                                                                                                                                              200
               i) in each bedroom; and                                                                                                                                                                                                                        NOTES:
               ii) in hallways which connect bedrooms
               and the rest of the                                                                                                                                                                                                                            All plumbing fixtures and installations including
               dwelling; or                                                                                                                                                                                                                                   pressure limiting devices, hot water systems and dual
                                                                                                                                                                                                                                                              flush toilet suites to be WELS rated in accordance with




                                                                                                                                                                                                       3000
               iii) if there is no hallway, between the
               bedrooms and other parts                                                                                  Dedicated Bicycle Spaces x 2                MEZZANINE                                                                                AS/NZ 6400 - 2005 & AS 3500, and incompliance with
               of the storey; and                                                                                                                                                                                                                             Part 4.1 of the Queensland Development Code (QDC).
               iv) if there are no bedrooms on a storey
               at least one smoke alarm                                                                                                                                                                                                                       All wet areas are to be waterproofed in accordance
               must be installed in the most likely path                                                                                                                                                                                                      with Clause 3.8.1, Vol 2 of NCC.
               of travel to exit the
               dwelling.                                                                                                                                                                                                                                      All glazing is to be installed in accordance with Clause
               Where practicable smoke alarms must                                                                                                                                                                                                            3.6, Vol 2 of the NCC.
               be placed on the ceiling. Smoke alarms
               must not be placed:                                                                                                                                                                                                                            Stairways are to be installed in accordance with Clause
               i) within 300mm of a corner of a ceiling                                                                                                                                                                                                       3.9.1, Vol 2 of the NCC.
               and a wall;
               ii) within 300mm of a light fitting;                                                                                                                                                                                                           Handrails and balustrades are to be installed to comply
               iii) within 400mm of an air-conditioning                                                                                                                                                                                                       with Clause 3.9.2, Vol 2 of the NCC.
               vent;
               iv) within 400mm of the blades of a                                                                                                                                                                                                            Masonry to comply with AS 3700.
               ceiling fan.                                                                                                                                                                                                                                   External fixtures & fittings to be non-combustible & hot




                                                                                                                                                                                                              14700
                                                                                                                                                                                                                                                              dip galvanised or of corrision resitant material.




                                                                                                                                                                                                       9110
                                                                                                                                                                                                                                                              Confirm all dimensions and design information on site
                     Gross Building Area                                                                                                                                                                                                                      prior to commencement of work.
                      Name              Area (m²) Squares (SQ)
              FLOOR                      77.3 m²      8.3
              MEZZANINE                  12.5 m²      1.3
              Total Use Area             89.8 m²      9.7




                                                                                                                                                                                      STORE




                                                                                                                                                                                                       90
                                                                                                                                                                                                       2500
                                                                                                                                                                                            WC




                                                                                                                                                                                                              200
                                                                                                                                                                  3910          90 1010 90 900




                                                                                                                                                  PROPOSED FLOOR PLAN
                                                                                                                                                  Scale 1 : 100




                                                                              MCU FITNESS CENTRE                                                                                                                                                                    SCALE @A3
                                                                                                                                                                                                                                                                                   0        1m        2m        3m       4m     5m


                                                                              ZEST BUILDING DESIGN STUDIO                       Project Address                                  Drawing Title                                                                                      1:100

                                                                             Sunshine Coast                                    2/37 Gateway drive, Noosaville
                                                                             P | 0457314346
                                                                             A | 30 Wattlebird Drive, Doonan, QLD 4562
                                                                             E | [email protected]
                                                                             W | www.zestbuildingdesign.com.au
                                                                              ABN: 37 601 151 508
                                                                              Q.B.C.C Lic. No: 1307012
                                                                                                                               QLD

                                                                                                                                Client Name
                                                                                                                                                                                 PROPOSED FLOOR PLAN
                                                                                                                                                                                                                                                                                                               A.02
                                                                                                                                                                                                                                                                                                           Phase     Bld #    Issue
                                                                              Designer (s)
                                                                              I. Brundell
                                                                                                                               RG STRATEGIC                                                                             1
                                                                                                                                                                                                                      Issue
                                                                                                                                                                                                                              MCU Application
                                                                                                                                                                                                                                                Description
                                                                                                                                                                                                                                                               30/08/2017
                                                                                                                                                                                                                                                                  Date
                                                                                                                                                                                                                                                                                 17077                     CA                  1
Original sheet size A3 (297x420)                           Plot date:   06-Sep-17 2:59:12 PM
                                                                                                                                                                                                                                                              MCU
Log in to download the original file

Appendix 3 - Bicycle Parking.pdf · 207 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.