Original source · versioned page text
Attachment 3 Soil Test Report
Attached to the e-mail MCU15/0045 Application for Detached House - Soil Test & SWMP - Email 2 of 2.
The norma! structural arrangement ts that the Inner leaf of brick-
work in the external wails and at least some of the internal walls
(depending on the roof type) comprise the load-bearing structure on
which any upper floors, ceilings and the roof are supported. In these
cases, it is Internally visible cracking that should be the main focus
of attention, however there are a few examples of dwellings whose
external leaf of masonry plays some supporting role, so this should
be checked if there is any doubt. In any case, externally visible
cracking is Important as a guide to stresses on the structure generally,
and it should also be rernembered that the external walls must be
capable of supporting themselves.
Effects on framed structures :
Timber or steel framed buttdings are less likely to exhibit cracking
due to swell/shrink than masonry buildings because of their
flexibility. Also, the doming/dishing effects tend to be lower because
of the lighter weight of walls. The main risks to framed buildings are
encountered because of the isolated pier footings used under walls.
‘Where erosion or saturation cause a footing to fall away, this car
double the span which a wall must bridge. This additional stress can
create cracking in wall Hinings, particularly where there Is a weak
point in the structure caused by a door or window opening. It is,
however, unlikely that framed structures wil! be so stressed as to suffer
serious damage without first exhibiting some or all of the abave
symptoms for a considerable perlod. The same warning period should
apply in the case of upheaval. It should be noted, however, that where
framed buildings are supported by strip footings there Is only one leaf
of brickwork and therefore the externally visible walls are the
supporting structure for the building. Tn this case, the subfloor
masonry walls can be expected to behave as full brickwork walls.
Effects on brick veneer structures s
Because the load-bearing structure of a brick veneer building is the
frame that makes up the interior leaf of the external walls plus
perhaps the internal walls, depending on the type of roof, the
building can be expected to behave as a framed structure, except that
the external masonry will behave in a similar way to the external leaf
of a full masonry structure.
i Water Service and Drainage
‘Where a water service pipe, a sewer or stormwater drainage pipe isin
the vicinity of a building, a water leak can cause erosion, swelling or
saturation of susceptible soil, Even a minuscule leak can be enough
to saturate a clay foundation. A leaking tap near a building can have
the same effect, In addition, trenches containing pipes can become
watercourses even though backfilled, particularly where broken
rubble Is used as fill. Water that runs along these trenches can be
responsible For secious erosion, Interstrata seepage into subfloor areas
and saturation.
Pipe leakage and trench water flows also encourage tree and shrub
roots to the source of water, complicating and exacerbating the
problem. :
Poor roof plumbing can result in large volurnes of rainwater being
concentrated in a small area of soil:
+ Incorrect falls in roof guttering may result in overflows, as may
gutters blocked with leaves etc.
* Corroded guttering or downpipes can spilt water to ground.
+ Downpipes not positively connected to a proper stormwater
collection system will direct a concentration of water to soil ihai is
directly adjacent to footings, sometimes causing large-scale
problems such as erosion, saturation and migration of water under
the building.
usness of Cracking a
Serio
In general, most cracking found in masonry walls is a cosmetic
nuisance only and can be kept in repair or even ignored, The table
below is a reproduction of Table C1 of AS 2870.
AS 2870 also publishes figures relating to cracking In concrete floors,
however because wall cracking will usually reach the critical point
significantly earller than cracking in slabs, this table is not
reproduced here.
iPrevention/Cure
Plumbing
Where building movement is caused by water service, roof plumbing,
sewer or stormwater failure, the remedy Is to repair the problem.
It ts prudent, however, to consider also rerouting pipes away from
the building where possible, and relocating taps to positions where
any leakage will not direct water to the building vicinity. Even where
gully traps are present, there Is sometimes sufficient spill to create
erosion or saturation, particularly in modern Installations using
~ sthaller diameter PVC fixtures. Indeed, some guily traps are not
~ situated directly under the taps that are Installed to charge them,
with the result that water from the tap may enter the backfilled
trench that houses the sewer piping. If the trench has been poorly
backfilled, the water will either pond or flow along the bottom of
the trench. As these trenches usually run alongside the footings and
can be at a similar depth, it is not hard to see how any water that js
thus directed into a trench can easily affect the foundation's ability to
support footings or even gain entry to the subfioor area,
Ground drainage
Jn all soils there is the capacity for water to travel on the surface and
below it, Surface water Flows can be established by inspection during
and after heavy or prolonged rain. If necessary, a grated drain system
connected to the stormwater collection system js usually an easy
solution.
It fs, however, sometimes necessary when attempting to prevent
water migcation that testing be carried out to establish watertable
height and subsoil water flows. This subject Is referred to in BIF 19
and may properly be regarded as an area for an expert consultant.
Protection of the building perimeter .
Te 4s essential to remember that the soil that affects footings extends
well beyond the actual building line. ‘Watering of garden plants,
shrubs and trees causes some of the most serious water problems.
For this reason, particularly where problems exist or are likely to
occur, it s recommended that an apron of paving be installed
around as much of the building perimeter as necessary. This paving
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.