Attachment 3 Soil Test Report
Attached to the e-mail MCU15/0045 Application for Detached House - Soil Test & SWMP - Email 2 of 2.
4.0 FINDINGS: The soil profiles encountered are shown on the attached borelog sections. No water table was encountered during our testing program. The sandy soils encountered are susceptible to collapse when unconfined. This may effect excavations and result in additional earthworks and increased concrete volumes. Temporary shoring or Forma-Tube may be required to retain the sands prior to concreting. The samples classified on-site were assessed as having negligible plasticity, therefore laboratory testing was considered unnecessary. We have assessed the expected differential movement of the soil profiles encountered to be the equivalent of a site with a Ys of less than 20mm. The foliowing foundation material ings within the scope of AS 2870-2011. ill provide a safe bearing capacity (100 kPa) for b FOUNDATION MATERIAL - NATURAL MEDIUM DENSE SAND We strongly recommend that any footing design for this allotment be carried out by a suitably qualified person in accordance with AS2870-2011. Where site drainage and landscaping does not conform to the specifications of AS 2870-2011 and CSIRO Information Service Sheet BTF-18 (2003) damage to the building can be expected. A single copy of this document is issued with the original issue of this report. Please consult your builder or contact this office to obtain a copy. NOTE: The information contained herein has been compiled following our field and laboratory testing, accepted engineering theory and discussions with and information supplied by our client, whom is noted on the header page of this report. We offer no warranty for the use of this report by other parties without prior written consent from this office. The report must be read in conjunction with the attached appendices. If you do not have a copy of these please contact our office and a copy can be issued to you. for and on behalf of: SCG CONSULTING ENGINEERS SCG CONSULTING ENGINEERS 2 SCG Ref: 24018(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.