Attachment 3 Soil Test Report

Attached to the e-mail MCU15/0045 Application for Detached House - Soil Test & SWMP - Email 2 of 2.

of 14

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

4.0 FINDINGS:

The soil profiles encountered are shown on the attached borelog sections.

No water table was encountered during our testing program.

The sandy soils encountered are susceptible to collapse when unconfined. This may effect
excavations and result in additional earthworks and increased concrete volumes. Temporary shoring

or Forma-Tube may be required to retain the sands prior to concreting.

The samples classified on-site were assessed as having negligible plasticity, therefore laboratory
testing was considered unnecessary.

We have assessed the expected differential movement of the soil profiles encountered to be the
equivalent of a site with a Ys of less than 20mm.

  

The foliowing foundation material ings within the

scope of AS 2870-2011.

ill provide a safe bearing capacity (100 kPa) for b

FOUNDATION MATERIAL - NATURAL MEDIUM DENSE SAND

We strongly recommend that any footing design for this allotment be carried out by a suitably
qualified person in accordance with AS2870-2011.

Where site drainage and landscaping does not conform to the specifications of AS 2870-2011
and CSIRO Information Service Sheet BTF-18 (2003) damage to the building can be expected. A
single copy of this document is issued with the original issue of this report. Please consult
your builder or contact this office to obtain a copy.

NOTE: The information contained herein has been compiled following our field and laboratory
testing, accepted engineering theory and discussions with and information supplied by
our client, whom is noted on the header page of this report. We offer no warranty for
the use of this report by other parties without prior written consent from this office.

The report must be read in conjunction with the attached appendices. If you do not
have a copy of these please contact our office and a copy can be issued to you.

 

for and on behalf of:
SCG CONSULTING ENGINEERS

SCG CONSULTING ENGINEERS 2 SCG Ref: 24018(S)
Log in to download the original file

Attachment 3 Soil Test Report.pdf · 2.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.