Appendix A - Revised Architectural Plans

of 13

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
NOTES:
                                                                        4080               6000                                 5420
All work to conform with Part MP 4.2 of the Queensland
Development Code (QDC) (Water Saving Targets).                                                    15500


Roof stormwater is to discharge to local government                                                             21180
requirements and approval. Downpipes not connected                                                                                                                                                       35°
to rainwater tank/s to discharge to interallotment
drainage system/ to nominated discharge points via
bubbler system/ to discharge to street channel system.

Based on assumed 5 minute rainfall intensity - 248mm/h                                                                                                                  STORMWATER
20 years recurrence interval.                                                                                                                                           TO EXISTING
                                                                                                                                                                        LAWFUL POINT
Gutters & downpipes shall be in accordance with                                                                                                                         OF DISCHARGE
AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 of the NCC.

                                                                   DP




                                                                                     455
All downpipes to be 90mm/100mm U-PVC.
All gutters to be 150 Quad Gutters (8600mm² Cross section area).
Falls to be in accordance with clause 3.5.2.4, Vol 2 of the NCC.

•    Effective roof catchment area 183.0m²
•    Number of downpipes 4
•    Roof catchment per downpipe 45.75m²
•    Downpipes must not serve more than 12m of gutter length for each
     downpipe                                                                                                                                        EG
•    Total rainfall intensity 183m² X 248mm/45.75= 992L/min             5°
•    Stormwater pipes - 100 dia. Laid at 1 in 100 minimum grade.                                                                5°

Downpipes are to be located where they will not                                15°                        15°
create a hazard to building users nor impede window
                                                                   EG
& door openings and the like. They are to be installed




                                                                                                                                                                                       11120
as close as practicable to the supporting structure
while maintaining termite inspection clearances of
25mm. Downpipes are to be protected from potential
mechanical damage, be installed no less than 100mm
from electrical cables & gas pipes & no less than 50mm                                                                                               DP
from other services (AS3500.3.2 S4.11)                             DP

                                                                                                                                                          EG
Downpipes are to service 12m maximum
gutter length & be within 1.2m from each                                                                                                                                        DP

valley unless overflow is provided for
(NCC Vol2 P3.5.2.5)




                                                                                                                                                               15°




                                                                                                                                                                                               3090
                                                                                                                        15°
    DP       DOWNPIPE ZINCALUME
    EG       EDGE GUTTER TO MATCH ROOF




                                                                                                                                                                       CD4d
                           new build                                                                                      REV          DESCRIPTION              DATE
                                                                                                                                                                       ROOF MAIN                      JOB:         21.34
WALK STUDIO                For:   ROBIN YATES                                                                                                                                                         DATE:        27.10.22
                                                                                                                                                                                                      DRAWN:       J.Walker
walkstudio.com.au
0409.921.601
                           SMOKE HOUSE
QBCC #15018637             16 Reserve St Pomona                                                                                                                        3.1
                                                                                                                                                                                                      SCALE(A3):   1 : 100
Log in to download the original file

Appendix A - Revised Architectural Plans.pdf · 5.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.