                                              .18-


        114.3.Additlonal load due to fill, constnJdion equipment or stockpiled materials should not be
                                                                         .



              located on the dune slope;
        114.4.The use of vibfatory equipment of any kind Is not permitted to be used, inclLtding vibtating
              rollers, the use of vibrating installation techniques for sheet pmng and other construc:tlon
              vibrations caused by excavating, ear1hmOYing or demolition machinery or other ,imilar
              Construction techniques;

        114.5.The construction management plan is to be adhered to;

       114.6.Copies of al Inspection reports by engineer&’ are to be submitted to Council within 5
            business days of the Inspection taking place;

       114.7.Boundary wall movement shall be monitored throughout construction by a Registered
         .
             Professional Engineer of Queensland (RPEQ)and If movement oc:c:urs construction Is to
              be stopped immediately and appropriate action Is to be taken to arrest the movement
              Further work ’!:Ian only take place after a re-assessment of the conditions on afte;

       114.8.A RPEQ is to be engaged by ltIe client to oversee the piling works and copies 01 all
            Inspection reports are to be submitted to COuncil Within 5 business days of the Inspection
             laking place;
       114.9.The applicant’s Geotechnical engineer will be required to be on site for the whOle of the
             time du(ing any exvatlon. The consbUction of the whole of the foundations Is to be
             lUP8!ViIed and directed on site by a oansulting Geotechnical engineer. No work of any
             such kind relating to the foundaUons shill be earned out If.geotechnical engineer is not
             on the Bite and supervJslng and dlrKtlng this work. Such works &haP only be carried out

             during dty weather conditions and If there Is a risk of sand movement occurring, all WDfk
             shall be suspended until such steps, approved by the applicant’s Geotechnical engineer
             and the Councif’s Building Surveyor, have been taken to ensure .that no further slippage
                                                                                             .

             will result.

Environmental HeaJtb
115.. An annual licence and regIstration of the premises Is required under the Food HygT6ne
      Regulation 1989 from Coundt’s Environmental Health Section for the guest house kitchen.
116.   Swimming pool or spa pumps are IQ be             ed in an acoustfea!ly treated enclosure or
       located in a manner which prevents 8 noise nuiSa~e beycnd the.subject land In accorda~
       with the environmental nuisanoe provisions of the Environmental Protection Regulation 1~98.
       On the spot fi~IIS’rnay apply for such offences.

117. Noise emission from air conditioning equipment shall complY with the following requirements:

       117.1.The equipment ahaH be Instaled and located in a manner which prevents noise nuisance
             beyond the subject land In accordance with the nuisance provillons of the Environtnntsl
             Protection Regulation 1998 and Councirs Local Law No. 12 Control of Nuisances.
                                                                               -




             Infringement NotIceS (on-the-spotfines) may     y for offences.
       117.2.Submlsston of written cerUflcatlon from a suitably quallfted person confirming that the
             noise levels comply when rneaSu~ at the nearest residential boundary. This Is required
            immediately after Installation of the equIpment and prior to any occupation of the building,
             and In a format approved by Council.

       117.3.Subject to the EnvironmentB!Protection Regulation 1989, the applicant must ensure that
             equipmen~ Is not used on ...y day it it make. or causes noise to be made
                                                                                        -




             117.3.1. Befor 78m’or after 1Opm: More than the Iowr of either-
                       .40d(B)A

                       .3d(B)A above the background noIae level

             117.3.2. FrOm Tam to 7pm: More than the lower of elther-
                       .So d(B)A

                       .5d(B)A above the background noiSe level

             117.3.3. From 7pm to 1Opm:More than 3 d(B)A.above the bacJcground noise level.

Used in these records

About this file

File size
37.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request to extend relevant period 132003.221199.3.pdf · 37.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.