Stormwater layout plans · MCU13/0092
Plans and drawings: the text below has words only, no drawings.
PROJECT TEAM
Consulting Engineer:
3
CATCHMENT SUMMARY TABLE i consulting pty ltd
engineering consultants
innovation, ingenuity, inspiration
CATCHMENT PLAN CATCHMENT PLAN
MINOR STORM EVENT Q20 MINOR STORM EVENT Q20 TREATED EVENT Q3 MONTH L2 39 Sherwood Rd PO Box 909
CATCHMENT AREA INTENSITY DISCHARGE INTENSITY DISCHARGE INTENSITY DISCHARGE Toowong, Qld 4066 Toowong, Qld 4066
DAV www.icubed.com.au [email protected]
ID L 0.306 m3/s 0.222 m3/s 0.043 m3/s
ABN 89 106 675 156 ACN 106 675 156
OW A 0.3494 ha 315 mm/hr 247 mm/hr 63 mm/hr
WA B 0.1023 ha 315 mm/hr 0.090 m3/s 247 mm/hr 0.065 m3/s 63 mm/hr 0.013 m3/s p 07 3870 8888 f 07 3870 8988
Y
C 0.1893 ha 315 mm/hr 0.166 m3/s 247 mm/hr 0.120 m3/s 63 mm/hr 0.023 m3/s
D 0.0094 ha 315 mm/hr 0.008 m3/s 247 mm/hr 0.006 m3/s 63 mm/hr 0.001 m3/s
CATCHMENT B
CATCHMENT C CATCHMENT LEGEND
LINE DESCRIPTION
FINSIHED SURFACE CONTOURS
CATCHMENT BOUNDARY
CATCHMENT A
CATCHMENT D
RUFOUS
STREET
CATCHMENT PLAN
1 : 500
MIN.
600
B CARPARK REMOVED 09.05.2013 T.J.S.
A FOR APPROVAL 14.03.2013 T.J.S.
REV DESCRIPTION DATE BY
Status
INLET PIPE TO BE CONNECTED DIRECTLY INTO
TANK, WALL TO BE SEALED AS REQUIRED FOR APPROVAL
NOT TO BE USED FOR CONSTRUCTION
Project
450X450 CONCRETE PIT PROPOSED SHOPPING CENTRE
WTH CONCRETE LID
RAINWATER TANK LOT 94 RUFOUS STREET,
REFER STORMWATER PLAN FOR SIZING
PEREGIAN BEACH
OVERFLOW PIPE TO MATCH SIZE OF for
INLET PIPE.REFER OUTLET SECTION UNDER GROUND TANK
FOR FURTHER DETAILS CONFIGURATION NOT TO BE USED
MULTISPAN AUSTRALIA Pty. Ltd.
HI-FLOW MOZZIE STOPPA
FLAP VALVE OR EQUIVALENT FOR ADJACENT TO STRIP FOOTING
FOUNDATIONS
RAINWATER TANK
Title
REFER STORMWATER PLAN FOR SIZING
CATCHMENT PLAN
OVERFLOW PIPE TO MATCH SIZE OF INLET PIPE.
REFER OUTLET SECTION FOR FURTHER DETAILS
Drawn Date Chkd Date
450X450 CONCRETE PIT
WTH CONCRETE LID M.R.R. 19.02.2013 N.C.
Design Date Apprd Date
T.J.S.
PLAN VIEW SECTION VIEW Scale A1 Certif Date
As indicated
Project No. Dwg. No. Rev
10/05/2013 9:42:25 AM
UNDERGROUND RAINWATER TANK 13-024 C34 B
c These drawings remain the property of i³ consulting pty. ltd. and must not be
copied in any format without the written permission of the owners of the copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Stormwater layout plansRelated documentApplication case desk ↗
About this file
- File size
- 133 KB (small file)
- File type
No other editions are linked here.