Council archive · source document
06/2435 - MCU - Education Type 3 - Adult [As Published] · 132006.2435
4. CAR PARKING The Driveways and Carparking Code requires for Education Use Type 3 Adult a minimum of 1 space per 10 students of driving age, plus 1 space per employee, plus a paved setdown area for buses. As the proposal is for adult education (university), it is assumed that all students will be of driving age. Carparking has been provided for the ground floor tenancies subject to this application at a rate of 1 space per 20m? of use area, in accordance with parking requirements for the approved office and medical use of the site. Based on the proposed use area of 647m”, a carparking credit of 32 spaces exists. 32 spaces could for example support in the order of 200 students plus up to 12 staff. As indicated in section 2 above student and staff numbers are estimated to be approximately 120 and 7 respectively, which equates to a requirement of 17 spaces. The provision of 32 spaces associated with the existing 647m? use area is more than adequate to accommodate the proposed use in accordance with Driveways and Carparking Code. A bus stop currently exists in front of the site within Goodchap Street. In addition, the existing on-site service vehicle loading areas could accommodate on-site bus setdown if required. The Driveways and Carparking Code also requires bicycle parking at the rate of 1 space per 30m’. Based on the proposed use area of 647m? this results in the need for 22 bicycle parking spaces. Similarly as with carparking assessments, consideration should be given to ‘credits’ associated with an existing use, such that only the difference between an existing and proposed use is applicable. In this regard the existing approved commercial business use can be assumed to have a credit of 13 bicycle parking spaces (based on the rate of 1 space per 50m’). As such the proposed Education use generates the need for 8 bicycle parking spaces. The existing development currently provides for 6 bicycle parking spaces and a uni-sex shower facility. As an existing development, limited opportunity exists for provision of additional bicycle parking and end of trip facilities. Should Council consider additional bicycle parking provision to be essential for the use and considering surplus carparks will result from the change of use, existing carparking spaces could be converted to bicycle parking. It is our opinion however, that as substantially more students are likely to travel by car than bicycle, retaining the surplus carparks is a more desirable outcome than strict compliance with bicycle parking requirements. With regard to end of trip facilities, we note these are only required where “at least 10 bicycle parking spaces are required”. Given that only 8 spaces are required in addition to the existing use credit, it can be argued that no additional end of trip facilities are required by the code. 5. CONCLUSION The proposal is for Education Use Type 3 Adult to be accommodated within the existing building. Education use is a consistent use in the Community Services Zone and is compatible with existing uses on site. The proposal supports collocation of community uses and is consistent with the overall and specific 31 October, 2006
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2435 - MCU - Education Type 3 - Adult [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type
No other editions are linked here.