                        Additional Conditions – 17 May 2023
                        Site Access and Driveways
                 37.    A sealed access driveway must be provided from Avocet Parade to all parking and
                        manoeuvring areas of Unit 2 (Lot 6 on 2SP215946). The works must be undertaken in
                        accordance with an Operational Works approval and must be generally in accordance
                        with the proposed driveway design included as part of RECOR’s Proposed Residential
                        Development drawing set (20220116) dated 27 September 2022.
                        Geotechnical Stability
                 38.    All works must be carried out in accordance with a Geotechnical Report (or part thereof)
                        prepared by a qualified person* and endorsed through an Operational Works approval.
                        Earthworks and Retaining Walls
                 39.    All fill and associated batters must be contained entirely within the subject site unless
                        written permission from the respective landowner(s) is provided to Council. All
                        earthworks must be undertaken in accordance with the provisions of Australian Standard
                        AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
                 40.    Where the development involves excavation or filling over, or adjacent to, drainage,
                        water supply or sewerage infrastructure, all access chamber surface levels must be
                        adjusted to provide a freeboard of 100mm above the finished ground surface level.
                 41.    All retaining walls must be designed and constructed in accordance with the planning
                        scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining
                        walls that are publicly accessible and exceed 1.0m in height must be fitted with a
                        commercial grade safety fence.
                        Damage to Services and Assets
                 42.    Any damage caused to existing services and assets as a result of the development
                        works must be repaired at no cost to the asset owner at the following times:
                        a.      where the damage would cause a hazard to pedestrian or vehicle safety,
                                immediately; or
                        b.      where otherwise, upon completion of the works associated with the development.
                        Any repair work which proposes to alter the alignment or level of existing services and
                        assets must first be referred to the relevant service authority for approval.
                        Building Appearance
                 43.    External design features, materials and finishes must be as shown on the Approved
                        Plans, with no inclusions or alterations made without approval in writing by Council.
                 44.    External finishes of the building must be a mix of lightweight and textured external
                        finishes, with masonry areas incorporating a variety of textured finishes to break up the
                        surface.
                 45.    All deck and balcony areas must not be enclosed with shutters, louvres, glass panelling
                        or the like thus remaining as open structures.
                 46.    External colours and finishes must be of an understated colour scheme and low-
                        reflective roofing and cladding materials.
                 47.    Waste storage areas, clothes drying areas and external storage areas must be screened
                        from view of the street.
                 48.    The boundary setback along the common boundary with Lot 343 P93114 is to be for soft
                        landscaping only, no services are to be provided in this area.




                                                                                                       Page 8 of 20
Document Set ID: 22435165
Version: 5, Version Date: 23/05/2023
Log in to download the original file

SUPERSEDED Decision Notice - Other Change - 132004 4029 01 & RAL22 0010 [As Published].pdf · 388 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.