a) results in a building scale that is compatible with                                                          comply with the Specific Outcomes of this element of the
surrounding development;                                                                                        code.
b) does not present an appearance of bulk to adjacent
properties, roads or other areas in the vicinity of the
site;
c) maximises the retention of existing vegetation and
allows for soft landscaping between buildings;
d) allows for adequate area at ground level for outdoor
recreation, entertainment, clothes drying and other
site facilities; and
e) facilitates onsite stormwater management and
vehicular access.
O10 Site cover does not exceed—
a) for a class 1 or class 10a structure within the
Detached Housing Zone, —
i for a single storey building - 50%; or
ii for a building of 2 or more storeys -
50% on the ground floor and 30% for the upper
storey(s), or 40% for all storeys for a building of 2 or
more storeys;
b) for other classes within the Detached Housing Zone
- 40%;
c) for the Semi-Attached Housing Zone—40%;
or
d) for the Attached Housing Zone—40%
e) for the Community Services Zone—50%
O11 For Multiple Housing Type 2 buildings have a
maximum plot ratio of 0.45:1.
O12 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4, or the accommodation
unit component of an Entertainment and dining
business Type 3—maximum gross floor area is
equivalent to the maximum allowable population
in persons multiplied by 40m2.
Flooding and drainage                                      S14.1 For new buildings or structures or             Complies.
O14 Buildings and other works are designed and sited       additions of more than 50m2 gross floor area to an
to—                                                        existing building or structure, floor levels for     The subject properties are not subject to Q100 flood
a) provide flood free access to premises and flood free    habitable rooms are—                                 inundation.
habitable areas;                                           a) for areas where minimum floor levels are
b) allow only minor, short term and infrequent flooding    available—not less than the specified level;
of non-habitable areas;                                    b) for areas where flood modelling is
c) ensure carparking areas can be adequately drained;      available—a minimum of 500mm above
d) ensure drainage does not adversely impact upon          the modelled flood level; and
other premises; and                                        c) for areas where flood modelling is not
e) ensure filling or excavation does not adversely         available, a minimum of 500mm above the highest
Log in to download the original file

Appendix H - Code Assessment.pdf · 412 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.