System components • Filter cartridges are designated as either high-flow or
draindown cartridges, depending on their location in
The JellyFish® filter is comprised of several structural and the cartridge deck. High-flow cartridges placed within
functional components: the backwash pool are automatically backwashed after
each storm event.
• A cylindrical precast concrete structure which is
available in a range of diameters and depths that • Draindown cartridges located outside the backwash
serves as a vessel providing structural support pool facilitate the draindown of the backwash
for a 50 year design life and provides storage for pool. The design flow rate (2.5 L/s) of a draindown
accumulated filtered pollutants. cartridge is controlled by the lid orifice. The lower
design flow rate of the draindown cartridge ensures
• A rigid high-strength fibreglass cartridge deck
the membranes last for longer periods between
separates the vessel into a lower chamber and upper
scheduled maintenance.
chamber. This houses the filter cartridges, provides
a surface and flow path for treated water to the • Cartridge lids are fastened into the deck to securely
effluent pipe, and provides containment of oil and anchor the filter cartridges. The lids are removable to
other hydrocarbons below the deck and also provides allow manual rinsing and replacement of the filter
a platform for maintenance personnel to safely service cartridges when required. Cartridge lids contain a
the filter cartridges. flow control orifice that is specifically sized for use
with high-flow and draindown cartridges. Blank lids
• The lower chamber provides storage for pollutant
have no orifice and are used to cover unoccupied deck
separation and membrane filtration.
apertures in systems that do not use the full rated flow
• The upper chamber provides adequate clearance for capacity of the system.
inspection and maintenance.
• A rigid fibreglass backwash pool weir extends
• A rigid high-strength fibreglass Maintenance Access 150 mm above the cartridge deck and encloses the
Wall (MAW) attenuates influent water velocity and high-flow cartridges. During inflow, filtered water
directs flow into the lower chamber through a large leaving the high-flow cartridges forms a pool inside
opening in the cartridge deck. In addition, it provides the weir. When the water level in the pool exceeds
storage for floatable pollutants. It also serves as an the weir height it overflows and spills to the cartridge
inspection and maintenance access point. deck where it then flows to the outlet pipe. As the
• JellyFish® membrane filtration cartridges are secured inflow event subsides and pressure decreases, water
to the deck by the cartridge lids. Each filter cartridge in the backwash pool reverses flow direction and
consists of multiple membrane filter tentacles, which automatically backwashes the high-flow cartridges,
treat the stormwater by filtering out fine suspended cleaning the membrane surfaces. Water in the lower
particulates (TSS) and particulate-bound pollutants on chamber (below deck) is displaced through the
the membrane of each tentacle. Filtered water passes draindown cartridges.
through the membranes, up the centre tube of each This self-cleaning mechanism may occur multiple
tentacle and exits through the top. times during a single storm event as rainfall/runoff
intensities rise and fall, thereby significantly
extending the service life of the cartridges and the
maintenance interval.
2 JellyFish® filter
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Jellyfish Compliance with SEQ MUSIC Modelling Guidelines.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.