Council archive · source document
Jellyfish Compliance with SEQ MUSIC Modelling Guidelines · MCU15/0122
Attached to the e-mail MCU15/0122 - Response to Information Request -Stormwater (Jellyfish compliance) Email 3 of 3.
Membrane filtration cartridge Figure 2 – JellyFish® membrane filtration cartridge
Head plate Lifting eyes
The JellyFish® filter utilises multiple lightweight
Attachment Gasket
membrane filtration cartridges. Each cartridge consists of nuts
multiple removable filter elements (“filtration tentacles”)
attached to a cartridge head plate. Each filtration
tentacle consists of a central perforated tube surrounded
by a specialised membrane. A removable oil-resistant
polymeric gasket provides a watertight seal between the
cartridge and the deck. A JellyFish® membrane filtration Tentacles
cartridge is depicted in Figure 2.
The cartridge length is 1,372 mm. The dry weight of
a new cartridge is less than 9 kg, and the wet weight
of a used cartridge is less than 23 kg. No heavy lifting
equipment is required during exchange.
The filtration tentacle membranes provide a large surface
area, resulting in high flow and suspended sediment These values translate to a conservative design
removal capacities. A typical JellyFish® cartridge with membrane filtration flux rate (flow per unit surface area)
11 filtration tentacles has 35.4 m of membrane
2
of 0.14 L/s/m2 for the high-flow cartridge and 0.07 L/s/m2
surface area. Hydraulic testing on clean filter cartridges for the draindown cartridge.
demonstrated a flow rate of 11.3 L/s at 455 mm of
driving head. In addition, the filtration membrane has been treated
to allow biofilm to grow but not clog the pores of the
Extensive independent field testing, including testing membrane. The flow rating of a particular JellyFish® filter
at an urban site with high intensity rainfall and runoff, cartridge is based on the membrane filtration surface
has demonstrated consistently high pollutant removal area of the cartridge and data collected from both
performance with a conservative design flow rate of laboratory testing and field testing. The cartridge deck
5 L/s for the high-flow cartridges and 2.5 L/s for the contains apertures for each filter cartridge.
draindown cartridges.
4 JellyFish® filter
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records