System options
The JellyFish® filter can be customised to suit your project
requirements. As each treatment train is unique and
units are designed to match surface levels, please contact
Humes for assistance, however, Table 2 below can be
used as a guide.
Table 2 – JellyFish® filter model range and details
Number of Nominal
JellyFish® Number of high- draindown Inlet pipe Treatment flow structure
model flow cartridges cartridges diameters (mm) (L/s) diameter (mm)
JF1200-1-1 1 7.5
1,200
JF1200-2-1 2 12.5
JF1800-3-1 3 17.5
1
JF1800-4-1 4 22.5
150 - 225 1,800
JF1800-5-1 5 27.5
JF1800-6-1 6 32.5
JF2400-6-2 6 35.0
JF2400-7-2 7 40.0
JF2400-8-2 8 2 45.0 2,400
JF2400-9-2 9 50.0
JF2400-10-2 10 55.0
JF3000-11-3 11 62.5
3
JF3000-12-3 12 225 - 300 67.5
JF3000-12-4 12 70.0
JF3000-13-4 13 75.0
JF3000-14-4 14 80.0
3,000
JF3000-15-4 15 85.0
4
JF3000-16-4 16 90.0
JF3000-17-4 17 95.0
JF3000-18-4 18 100.0
JF3000-19-4 19 105.0
JF3600-20-5 20 112.5
JF3600-21-5 21 117.5
300 - 375
JF3600-22-5 22 122.5
JF3600-23-5 23 127.5
5 3,600
JF3600-24-5 24 132.5
JF3600-25-5 25 137.5
JF3600-26-5 26 142.5
JF3600-27-5 27 147.5
Note: Designers should allow for upstream and downstream bypass pits and a bypass pipe link in a triangular configuration.
8 JellyFish® filter
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Jellyfish Compliance with SEQ MUSIC Modelling Guidelines.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.