Original source · versioned page text
Approved Plan - MCU23/0154
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
27750
WINDOW HEAD HEIGHT SCHEDULE
6*
COV
PMT
PA
12990 5530 4200 5030 CODE
TOP OF * HEAD HEIGHTS TO GARAGE WINDOWS ARE TO BE MEASURED FROM
ALUMINIUM GARAGE FLOOR LEVEL.
A 2150 * ALL WINDOWS WITH A "DG" AT THE END OF THE CODE ARE DOUBLE
5060 4670 S 2245
GLAZED.
* ALL WINDOWS WITH A "BS" AT THE END OF THE CODE TO HAVE A
FINAL DRAWINGS o/a alfresco BARRIER SCREEN.
240 5050 240 * ALL WINDOWS SIZE CODES ARE NOMINAL.
CHECKED BY: CB EXT No. 8871
CHECKED TO: PTVO 2 & 3 dining
DATE: 21/07/2023 240 1410 90 4200 90 2860 90 90 1460 90 1800 90 720 9250 240
w.i.r./ bed 4 bath ledge w.i.l. l'dry ref. dining / living PROVIDE STUDS 300mm OFF BACK WALL
store 1850 90 1010 space 1050 140 2860 140 5060 90 1900 90 90 2860 240 ADJACENT TO OVERHEAD CUPBOARDS & ALL
bath p'dr 2 opening kitchen living dressing ledge ensuite SHELVING IN THE HOUSE TO ALLOW FOR SIDE
LEGEND 4800 90 1250 1420 90 1050 1770 180 1180 90 1600 90 1680 3380 910 90 1190 760 FIXING
DIRECT WIRED SMOKE ALARM FLOOR WASTE (ROUND) bed 4 p'dr 2 b'pantry pantry p'dr opening w.c. opening
EXHAUST FAN PROVIDING MIN. 40 LT/SEC WASTE OVERFLOW/OUTLET 470 3730 470 BULKHEADS 290mm BELOW CEILING UNLESS
D
(ROUND)
CLEAN AIR CONNECTED TO LIGHT SWITCH
FLOOR WASTE (SQUARE)
pier pier NOTED OTHERWISE.
IO OPENING IN WALL FOR PLUMBING
RISER STACK INSPECTION OPENING WASTE OVERFLOW/OUTLET
710
dp
(SQUARE)
IO OPENING IN FLOOR FOR PLUMBING
470
pier
INSPECTION OPENING FLOOR WASTE (BERMUDA)
990
990
tap GARDEN TAP ENERGY EFFICIENCY TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA.
CA EILIN
LI N L
mh MANHOLE 700X500 710 75x75 SHS posts
CEI EDRA
WALL SISALATION (VAPAWRAP) TO EXTERNAL TIMBER FRAMED WALLS (NOT 20-18(S) 20-18(S)
THE G
C
G
SV SNAP VENT to alfresco piers
METER BOX
240
NO LIN AAW FS-F NO LIN AAW FS-F
LOUVRE dp
BETWEEN HOUSE & GARAGE).
DR A
TH
EV EAVE VENT / FV FASCIA VENT
690
GAS METER
o/a alfresco
CA
F
FRIDGE POINT INVERTER PV CELL PROVIDE R1.5 WALL INSULATION BATTS TO EXTERNAL WALLS.
L
2051x850(S) 2051x850(S)
(REFER TO FRIDGE SPACE DETAIL) METER BOX PROVIDE R2.5 CEILING INSULATION BATTS TO HOUSE. ALFRESCO
3750
CAPPED COLD WATER POINT
ALW
C
A/C DUCTWORK
3280
(REFER TO FRIDGE SPACE DETAIL)
H CAPPED HOT WATER POINT ROOF SARKING TO ENTIRE GROUND FLOOR ROOF. plaster ceiling broom finished
2760
ROOF VENT
PROVIDE R2.5 INSULATION TO CEILING EXTERNAL PERIMETER.
RECESSED
NO LIN
CAPPED WASTE POINT
86mm stepdown to
AST24-23
W
DINING integral slab to
G CAPPED GAS POINT GB GB GAS BOTTLES
ASSUMES MEDIUM COLOURS & DRAPES BY OWNER AFTER HANDOVER. alfresco
590
grand alfresco;
RECESSED min 1:100 fall
4540
LOUVRE
ALW
1200h x 90d tiled AST24-29
shower ledge refer to fridge
240
NO LIN
dp
dining
5840
1380 1970 1330 EV space detail 1200h x 90d tiled
710
shower ledge
1780
2051x850(S)
valley not @ 45° 350
LOUVRE
living / dining
20-08(S)
ALW
NO LIN
tap EV H/P EV
dp dp
8100
12-21(S) 12-14(A) HWS 20-06(S) clear glass 20-18(S)
NO LIN
AFW
240
240
LOUVRE dp
NO LIN ASW FS-F NO LIN ASW FS-F NO LIN AFW NO LIN AFW
350
2051x610(S)
W.I.R 1675 bath F
NO LIN
KITCHEN
820
ref LIVING 1700 bath
180 1300
ref.
1600
w.i.r.
DRESSING
ledge
ALW
space bulkhead 290
1720
living
5340
ledge
1960
2340h W.I.L IO
IO w/m below ceiling valley not @ 45°
2560
2580
bath
dp
w.i.l.
720 vb shr space shr tap
bed 4 / l'dry
dressing
ensuite
90 640
BATH vb
nib
800 730
BED 4
90
3560
3650
3650
90
BUTLER'S
A/C
90
vb L'DRY
opening
2340h
PANTRY Provide wall
2340h
STORE 2340h
720
vb
b'pantry
720
p'dr / pantry
16700
mh
2170
noggings @
P'DR 2
store
1960
720 ENS
p'dr 2
P'DR
1000 90
1840
980 90
565x700
1620
1600
1400h ffl W.C
w.c.
tall vb
p'dr 2
2340h
2340h 2340h vb 2340h cup'd
820
820
PANTRY
2340h
2340h
720
2340h
820 720 820
720
50
720
180
180
90
1200 90
90
2340h
A
8740
opening
820
C
90 1200
180 1200
2340h A/C 920
820
10210
NO LIN
300
2340h
580
270
2340h
W.I.R
820
GB GARAGE
820
C/S 2340 x 1020
master suite
See the original