Original source · versioned page text
Attachment 1.pdf
DRAWING SIZE — Al Level Datum AHD Watterson & Associates HEIGHT DATUM Lot 1 & 2 on RP 73072 Level Origin PM 18416, Survey information provided by Max RL 9.967m 43077 _it 4 418.0 RAMP. <x. /D S/EX — sw/ex eee RW SS = RETAINING TO SIDE OF BUILDINGS TO MAINTAIN EXISTING SURFACE LEVELS DOWN BOTH SIDE BOUNDARIES FOR | OVERLAND FLOWS o. 2s. &. f+ G Ce “ey a “, + L Y + 3 8 &, (0142) “9, t+, “se on & 0.142 Se Sy & - x ay ce, [7 Li] & O. S % | t+to Pey MINOR RESHAPING TO EX. GROUND LEVELS IN ROAD RESERVE FOR NEW DRIVEWAY. ENSURE MIN. COVER TO SERVICES ARE MAINTAINED AND RE-TURF. L.| Lo ° eH La Lo NX +T 1:3 MAX BATTER, TYPICAL. LEGEND INDICATES EXISTING SURFACE CONTOURS AND LEVELS TO AHD. INDICATES FINISHED SURFACE GRADE EXISTING SURFACE SPOT LEVELS. INDICATES DIRECTION OF RAMP UP OR DOWN AS INDICATED INDICATES DEPTH OF CUT (NEGATIVE) OR FILL (POSITIVE) AS NOTED INDICATES OVERHEAD ELECTRICITY SUPPLY LINE INDICATES EXISTING SEWER LINE INDICATES WATER MAIN APPROX ALIGNMENT, BUILDER TO CONFIRM EXACT LOCATION PRIOR TO WORKS INDICATES TELSTRA LINE APPROX ALIGNMENT, BUILDER TO CONFIRM EXACT LOCATION PRIOR TO WORKS INDICATES STORMWATER DRAIN EXISTING AS NOTED &. _ LANDSCAPED ot a 6. & es iy O. & + |S. eg ot ut ~ Yn Z Op, |e ve ta, [it re = Z = = », LO x an 6, % , \(0.086) 5, C085) 3 %, | Sze 4 Z4 4 Sp, 6 4+) ON ai x Se re RETAINING 10 SIDE OF BUILDINGS TO | gas MAINTAIN EXISTING SURFACE LEVELS > DOWN BOTH SIDE BOUNDARIES FOR | INDICATES POSITION OF RETAINING WALL TO FUTURE DETAIL. INDICATES AREA OF FILL INDICATES AREA OF CUT www.dialbeforeyoudig.com.au DIAL1100 BEFORE YOU DIG REFER Drg 31031-C3.1 FOR DRIVE WAY DETAILS. OVERLAND FLOWS SITE PLAN — EARTHWORKS Scale 1: 150 ALL SERVICES SHOWN ON THIS PLAN INDICATIVE ONLY CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO COMMENCING WORKS ON SITE. ALL NOTE: CUT/FILL LEVELS SHOWN REPRESENT THE PAD LEVEL TO THE UNDERSIDE OF THE GROUND BEARING SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER DUST OR ROAD BASE LAYERS TO BE PROVIDED UNDER THE SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED. SERVICES ARE TO BE PROTECTED IN ACCORDANCE WITH THE AUTHORITY RESPONSIBLE FOR THE SERVICE THE BUILDER/CONTRACTOR SHALL CONFIRM ALL RELEVANT LEVELS PRIOR TO COMMENCING WORKS. LZ KEY EX. SWPT EXISTING STORMWATER PIT RC. HW. EX. SMH — EXISTING SEWER MANHOLE E.0.B. EXISTING EDGE OF BITUMEN K&C EXISTING KERB & CHANNEL NS.L. NATURAL SURFACE LEVEL FH. FIRE HYDRANT TP TELSTRA/NBN PIT EP. ELECTRICAL POWER POLE ET. ELECTRICAL TRANSFORMER W.M. WATER METER KERB EXISTING KERBING BUILDER TO MAINTAIN STABILITY OF NEIGHBORING PROPERTIES DURING EARTHWORKS. POST & PLANK WALLS CAN BE USED IF EXCAVATIONS CLOSELY FOLLOWED BY PLANK INSTALLATION OR ALTERNATIVE SITE RETENTION MEASURES WILL BE REQUIRED. GROUND / ZZ THIS FOOTING WITHOUT y—— PIERS IS FOUNDED ABOVE CRITICAL DEPTH LINE AND IS UNSTABLE. THIS FOOTING IS FOUNDED BELOW CRITICAL LINE AND IS STABLE. PIERS SUPPORTING STRIP FOOTINGS OR \\ POST PAD FOOTINGS FOUNDED INTO SELECTED MATERIAL AND BELOW CRITICAL LINE ARE CONSIDERED STABLE. STABLE \G Oy Wey, PAD LEVEL UNSTABLE aa) NS N NOTE: THIS DETAIL ALSO APPLIES TO EXISTING FOUNDATIONS ON NEIGHBOURING PROPERTIES. SHEET PILING MUST BE INSTALLED WHERE EXISTING FOOTINGS WILL BE FOUNDED ABOVE ANY EXCAVATION CRITICAL DEPTH LINE T | THE BUILDER/CONTRACTOR | MUST CONFIRM ALL | RELEVANT LEVELS PRIOR TO COMMENCING WORKS. | | | LINE OF PROPOSED Le POOL EXCAVATION OR OTHER TRENCH. XN of. sown HORIZONTAL Nye (—\ CRITICAL DEPTH LINE - EXCAVATION (7 PPRICAL SECTION 0 2 4 6 8 REINFORCED CONCRETE HEADWALL 10 rm :150 @ AI CONSTRUCTION NOTES GENERAL: 1. DO NOT SCALE FROM THIS DRAWING. 2. ALL DIMENSIONS IN MILLIMETRES 3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY. 5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE DIAGRAM. FILLING NOTES —THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND DEBRIS. —THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 98%. THE COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7 BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL. —UNLESS NOTED OTHERWISE A MINIMUM BEARING CAPACITY OF 100kPa SHOULD BE ACHIEVED WITHIN COMPACTED FILLING. COMPACTION & BEARING CAPACITY TEST RESULTS MUST BE PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL PRIOR TO WORKS PROCEEDING. THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND TO A CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12% (PLASTICITY INDEX LESS THAN 25%, LINEAR SHRINKAGE OF 15%). THE PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATIBILITY. —THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 98%. COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL. FILLING AND COMPACTING ADJACENT EXISTING STRUCTURES IS TO BE IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND SPECIFICATIONS. —AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 98%. —ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 98%. ~SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED PRIOR TO CONSTRUCTION COMMENCING. A EARTHWORKS AMMENDED 25.11.21 Revision | Description Date Issi * FOR APPROVAL DO NOT SCALE FROM THIS DRAWING The design and associated details contained on this and associated drawings are copyright and are not to be used or reproduced without the written permission of SCG Consulting Engineers. Unit 1/11 Project Ave, Noosa Heads Ph (07) 5455 5604 email:[email protected] web:www.scg-engineers.com ‘ABN 40 098 481 699 O see DEBUILD T/A, CONSULTING Title: EARTHWORKS PLAN 29-27 TOOLAR St, TEWANTIN Date: Nov 21 Drawn SR Design SR 1500 6 5 || SER, i 31030-C2.1| A
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment 1.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.