DRAWING SIZE — Al
HEIGHT DATUM
Lot 1 & 2 on RP 73072
Level Datum AHD
Level Origin PM 18416, RL 9.967m
Survey information provided by Max
Watterson & Associates
RAINFALL
SITE AREA UNDER 2500m?
ALTERNATIVE MEASURES FOR
WSUD IMPLEMENTED
WATER TANKS
-FOR RE-USE & DETENTION
i>
ROOF RUNOFF
WATER TANKS
Y 2
DRIVEWAY
GPT
GPT— GROSS POLLUTANT TRAP
—CAPTURES GROSS POLLUTANTS OJ
+
OPERATIONAL WORKS APPLICATION
SCHEMATIC PROPOSAL ONLY DETAILED DESIGN ISSUED AT
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN. INSTALL TO
NEW KERB ADAPTORS AND MAKE
FOOTPATH GOOD. TYPICAL.
g
: g
L..
4 %
FALL LANDSCAPED AREAS TO FORMED
FLOW PATHS. DIVERT FLOWS TO
RICHARDS STREET FRONTAGE. 1: 150
MIN FALL. TYPICAL.
+ +,
AY
SWACE— a? Ware — <} SWALE =~ <P SWALE — <P
a
f/f fe 7 ARP
i
“,, FFL 13.75
g
SO. ~T
&
RESIDENTIAL
DEVELORMENT
Z|
3 /
a = ye FFL 13.75
g “+ &. + he
2 y WA
RUNOFF TO COUNCIL
INFRASTRUCTURE
WATER CYCLE DIAGRAMATIC
FOR THE SERVICE
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY RESPONSIBLE
ALL PIPES TO BE LAID AT 1 IN 100 MIN.
UNLESS NOTED
LEGEND
__---7 INDICATES PROPOSED SURFACE
4807 CONTOURS AND LEVELS TO AHD.
5.0% > INDICATES FINISHED SURFACE GRADE
4\89 EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF RAMP UP OR
RAMP.
— DOWN AS INDICATED
FALL. INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
STORMWATER JUNCTION BOX, PRE-CAST
J" CONCRETE. AND SEALED LID
=e GRATED FIELD INLETS, WITHIN PATH AND
= TERRACE AREAS
GD-200 200(W) GRATED DRAIN WITH HEAVY
(ee) SOC(éUTY ‘GRATE.
INDICATES STORMWATER DRAIN PROPOSED
Sw
AS NOTED MIN 1 IN 100 FALL UNLESS
NOTED OTHERWISE
R-swW INDICATES ROOF STORMWATER DRAINAGE
LINE TO HYDRAULIC DESIGNERS DETAILS.
DP INDICATES DOWNPIPES FROM ROOF. REFER
HYDRAULIC CONSULTANT FOR DETAILS
..\..\Documents\Dial—Before—You—Dig—HD.JPG
sw— Ss.
fl
a
—_—
¢
SWALE > —— SWALE —>
O Ww
a Jf
vu y
><
KEY
EX. SWPT EXISTING STORMWATER PIT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
WM. WATER METER
DOWNPIPES (DP) SHOWN
Pee DIAGRAMATIC TO DEMONSTRATE
y STORMWATER MANAGEMENT.
NUMBER AND LOCATION TO BE
DETERMINED BY HYDRAULICS
CONSULTANT & ARCHITECT.
PROPOSED LOCATION FOR
Sy
FFL 14.600 ©,
ORMED FLOW INVERT — pereR Dig 31031-C31. Tf
+
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN. INSTALL TO
NEW KERB ADAPTORS AND MAKE
FOOTPATH GOOD. TYPICAL. &p.
ZI
J
SWALE —> —— SWALE —> —— SWALER>
WL obey
ESIDENTIAR, Delf + 4
; 0 TE 3 20.
|
{ 4
Sewer M/H
Xe
LL: 14.11
(L: 12.79
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN. INSTALL TO
NEW KERB ADAPTORS AND MAKE
FOOTPATH GOOD. TYPICAL.
TT a >= =I TX FoR DRIVE WAY DETAILS, = =t=y- Rake Beton | — eA 4, JPBVELOPMEN| 7 OF p
_ cy \ m sy i + uy
<M = BORO = :
Ay. “Z \ ws 7 FFL 15.00 Ko,
Oo DK O \ 4 R-Sw R-Sw k-sw R-sw R-sw r-sw Ye Pe
0. . xo.
ent \\ a 4A |
5 a\ ] y
FFL 1468 9 = a 4 . °
/ P eY| \ ay DF \
4 % 5 \ Z y <a &q | | 4
— = ‘O: - z
\ 2 Zh 8 a ~ 1 | &, 5
+ ww \ 2% | ppl 1+ |
RESIDENTIAL A \ 2 ' FAL. I j ! As
or ws al J , (Oo
| PEVELORMENT YS, % \2 9 $ 4
% \e | 1 ;
ys < 3 m™m
lt Zi we ¢ \ i FFL 15.20 j &. |
+ 9
tb, cS o \ 2. 0 “4
© 8 DP \ a z
<4 46 z \ SH =
FFL 14.68 &, i \ 2
Tf LH |
, R-SW R-SW R-SW R-SW R-SW
Xp * 5
sw—& 7 sw swhr
<S.
+ %
&
*&
SITE PLAN — CONCEPT STORMWATER MANAGEMENT PLAN
HEAVY DUTY TRAFFICABLE
SEALED ACCESS HATCH
TRAFFICABLE CONCRETE
DETENTION TANK FOR ROOF
DRIVE WAY STORM WATER
ONLY, MIN CAPACITY 28000 It
DRIVE WAY SLAB
Scale 1: 150
oO
——
SE
=o
Be
i= {i =
ROOF STORM WATER
INFLOW 7000 Lt MIN.
STORAGE TANK
RE-USE PUMPING AND
RETICULATION BY OTHERS
STORAGE TANK DETAIL
225 DIAM TANK OVERFLOW PIPE
=> 3
WATER DETENTION TANK
DETENTION ZONE
21,000 It
225 DAM —
LOW FLOW ORIFICE, 5mm
135mm ORIFICE HOLE.
DETENTION TANK DETAIL
DETENTION /RE-USE
IN-GROUND STORMWATER
TANK(S)
SITE STORMWATER MANAGEMENT
EXISTING SITE
- SITE AREA = 2020m’?
- IMPERVIOUS AREA = 510m?
PROPOSED SITE
— IMPERVIOUS AREA = 1320m?
SITE_RUNOFF
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL
NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH
LINE DIAGRAM.
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN THE
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS39500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS DO NOT
CLASH WITH THE PROPOSED PIPE WORKS PRIOR TO THE COMMENCING
OF WORK.
5. ALL TRENCH EXCAVATIONS AND CONSTRUCTION TO BE IN ACCORD
WITH WORKPLACE HEALTH & SAFETY 1989 AND ANY AMENDMENTS AND
THE MINE REGULATION ACT.
6. STORMWATER DRAINAGE PIPES SHALL BE LAID AT A MINIMUM GRADE
OF 1 IN 100 U.N.O. JOINS ARE TO BE CONSTRUCTED IN ACCORDANCE
WITH THE MANUFACTURERS REQUIREMENTS. (REFER NOTE 10.)
7. ALL PRECAST CONCRETE PIPES AND TO MANUFACTURED IN ACCORD
WITH AS. 4058.
8. STORMWATER PIPES SHALL BE THE FOLLOWING CLASSES:
8.1. REINFORCED CONCRETE PIPES (RCP) = CLASS 2.
8.2. uPVC 1008 OR GREATER = CLASS ‘SN8’.
8.3. "STORMPRO’ PIPES = CLASS ’SN8’.
9. ALL RCP PIPES TO HAVE THE FOLLOWING JOINTS U.N.O:
9.1. RCP 600¢ OR LESS = RUBBER RING JOINT.
9.2. RCP 600@ OR GREATER = FLUSH JOINT.
10. ROOF STORMWATER TO DESIGN BY HYDRAULIC CONSULTANTS TO
CLASS *SH’ U.N.O.
11. INSTALL SW MANHOLE AND FILED GULLY/INLETS IN ACCORDANCE
WITH AS1657 AND AS DESCRIBED BELOW:
11.1. MANHOLE/FIELD INLETS >1.35m DEEP = STEP IRONS.
11.2. MANHOLES 0.85m—3.0m DEEP = STEP IRONS.
11.3. MANHOLES >3.0m DEEP = FIXED ACCESS LADDER.
12. SEWERS 100mm DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
OF 1 IN 60.
13. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE:
13.1. 63mm DIAM. OR LESS —- HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
14. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO
BE TYPE B COPPER.
15. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
16. FIRE HYDRANTS ARE TO BE INSTALLED IN ACCORDANCE WITH
AS2419.1. HOSE REELS ARE TO BE INSTALLED IN ACCORDANCE WITH
AS2441. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS
SITUATED IN VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED
WITH EITHER BRASS OR CAST-IRON COVERS.
17. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
18. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
19. THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE.
— FROM QUDUM USING RATIONAL METHOD:
SITE_RUNOFF
EXISTING PROPOSED
INCREASE
Qto 92.7It/s 103It/s
Qn | Milt/s 122It/s
Qin | _158it/s 170It/s
10it/s
12It/s
12It/s
NON-WORSENING
— ON-SITE DETENTION TANK WITH SLOW
PIPES TO BE PROVIDED.
STORMWATER QUALITY
- THE SITE AREA IS BELOW 2500m?
— STORMATER HARVESTING TREATMENT
MEASURES TO BE IMPLEMENTED.
LEAK
— 101It OF STORAGE TO BE PROVIDED FOR
EVERY 1m? OF ROOF AREA. 80% OF ROOF
FLOW TO DRAIN THROUGH STORAGE TANK.
— STORED WATER TO BE USED FOR ON
IRRIGATION & EXTERNAL USE.
OPENING | TYPICAL OPENING
BETWEEN
DETENTION TANKS.
STAINLESS STEEL PLATE WITH A
(-x\ DETENTION TANK CONNECTION OPENING.
\_/ TYP. SECTION
0 2 4 6 8 10
Checked: Drg No. R
Pp mt: 150 © AT peg 5935 31 030-C5 {
SITE
A DETAIL UPDATED 25.11.21
Revision Description Date
Issue:
FOR APPROVAL
the written permission of SCG Consulting Engineers.
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
ABN 40 098 481 899
DEBUILD T/A,
Unit 1/11 Project Ave,
PS Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
Title:
CONCEPT STORMWATER
MANAGEMENT PLAN
29-27 TOOLAR St,
TEWANTIN
Date: Nov 21 Drawn SR Design SR
1:300 @ A3 : S Richardson A.
Preview the original