Original source · versioned page text
MCU16/0079 Appendix F - Environmental Noise Imact Assessment
3.4 Attended Background Measurement Methodology and Results
Attended background noise level surveys were conducted directly across Pelican Street from the
logger location. Refer to Figure 2 in Appendix A for the measurement location.
Measurements were conducted with a Rion 29E Octave Band Sound Level Meter set in “C” Weight
Fast Response, with the microphone approximately 1.5m above ground level.
Measurements were conducted generally in accordance with Australian Standard AS 1055:1997 –
“Acoustics-Description and measurement of environmental noise”.
The operation of the sound level equipment was field calibrated before and after the measurement
session, with no significant drift from the reference signal recorded.
Weather conditions during the test were fine and calm, with a temperature of approximately 22ºC.
Table 2 below presents the adjusted background noise levels recorded at the measurement location.
The background levels presented in Table 2 below have been adjusted to closer reflect the minima
background levels presented in Table 1 of Section 3.3.
Short-term SPL dB(C) Hz Octave Band Centre
Octave Band Noise Measurements Frequencies
63 125 250 500 1k 2k AP
Night-time L90 Ambient Noise Level 48 43 39 35 33 27 50
Table 2: Measured LC90 octave band ambient noise levels at the measurement location.