ATTACHMENT 2 - CERTIFICATES FOR PERMIT No. 9846


The following tables provide a list of the certificates that are likely to be required before a Final Inspection Certificate
(Form 21) can be issued for the building work. This list is subject to confirmation by Urban Certifiers after carrying
out a final inspection, and additional certificates may be required. Certificates must be from an approved competent
person or a QBCC licensee.
Certificates are required to be in the approved form (Form 15 or 16 as appropriate). In some cases it will be
necessary for these certificates to be supported by evidence of suitability.


                                                 STAGE CERTIFICATES
   No. Stage                            Notes
                                        This certificate can only be issued by a building certifier, but can be
   a)   Footing Stage                   based on a structural aspect certificate from a registered engineer and a
                                        setout aspect certificate from a cadastral surveyor is provided.
   b)   Slab Stage                      From Urban Certifiers or a competent person (e.g. a registered engineer)

   c)   Frame Stage                     From Urban Certifiers or a competent person (e.g. a registered engineer)

   d)   Pool Barrier                    This certificate can only be issued by a building certifier.

   e)   Final Stage                     This certificate can only be issued by a building certifier.



                                                ASPECT CERTIFICATES
   No. Type                             Description
   a)   Building setout                 Form 16 from a cadastral surveyor confirming the building has been
                                        located on site in accordance with the approved plans.
   b)   Termite management              Form 16 from a QBCC licensed termite protection contractor, confirming
                                        the building has been provided with a termite management system in
                                        accordance with BCA Part 3.1.3 and AS3660.1-2014. A copy of the
                                        treatment plan/diagram should also be provided.
   c)   Roofing                         Form 16 from a QBCC licensed contractor, confirming the roof
                                        installation complies with NCC Part 3.5.1 and AS1562.1-1992.
   d)   Gutters                         Form 16 from a QBCC licensed contractor, confirming the gutter
                                        installation complies with NCC Part 3.5.3 and AS/NZS3500.3-2015 or
                                        section 5 of AS/NZS3500.5-2012.
   e)   Stormwater Drainage             Form 16 from a QBCC licensed contractor, confirming the stormwater
                                        drainage complies with NCC Part 3.1.3 and AS/NZS3500.3-2015.
   f)   Glazing - windows               Form 15 from the window manufacturer confirming the windows supplied
                                        for the project comply with AS2047-2014- and AS1288-2Q06.
   g)   Glazing - windows               Form 15 from the window manufacturer confirming the windows supplied
                                        for the project comply with the required energy efficiency ratings for U-
                                        value and SFIGC.
   h)   Glazing - shower screen         Form 15 from the shower screen manufacturer confirming the glass
                                        supplied for the shower screens comply with AS 1288-2006.
   i)   Smoke alarms                    Form 16 from the electrician confirming the smoke alarm comply with the
                                        Building Regulation 2006 and the NCC Part 3.7.2 (refer to conditions of
                                        approval for more detailed location requirements).
  j)    Bushfire construction           Form 16 from the builder and relevant contractors/suppliers (e.g. window
                                        glazing) confirming the materials and method of construction complies
                                        with the BAL requirements specified und AS3959-2018.
   k)   Mechanical ventilation          Form 16 confirming the exhaust fans used to provide mechanical
                                        ventilation comply with the flows and discharge requirements specified in
                                        NCC Part 3.8.7.3.



6 ROBIN PLACE, LAKE MACDONALD
PERMIT NO 9846                                                                                                  PAGE 6 OF 8

Used in these records

About this file

File size
21.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Operational Works Application OPW21_0243 - Driveway application and supporting documents - 6 Robin Place, Lake MacDonald.pdf · 21.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.