GENERAL NOTES

Toilet doors are to open outwards or be fitted
with lift off hinges in accordance with part 3.8.3.3
of BCA Housing Provisions.

 

 

 

All glazing in buildings to comply with the
requirements of part 3.6 of BCA2006 Housing
Provision and AS1288/2005. A glazing certificate
from the manufacturer for compliance with
AS1288 must be provided on completion.

Where existing crossover is modified the builder
shall construct Kerb & Channel to match
adjacent and to local authority requirements.

All Balustrading to Decks shall be engineer
certified.

Builder to allow for disposal from site all waste
materials during demolition and construction
period.

Smoke alarms must comply with AS 3786 and
be connected to the consumer mains power.
Smoke alarms must be located in accordance
with part 3.7.2.3 of the building code of Australia.

 

     

SUBTERRAIN J ~S
GARAGE
UNDER

 

anes”

NL

 

 

 

 

a>

ING
LION

 

 

 

 

 

 

 

 

 

 

 

 

fall >

 

 

 

 

 

 

 

 

TANKING OF HABITABLE
AREAS

All steps in floors where retaining walls have
been installed or where retaining walls are used
as extemal walls of habitable rooms are to be
waterproofed by an approved tanking system
and installed by an accredited installer.

 

The approved system is to be certified for
compliance upon completion.

EXCAVATIONS

Sheet Piling to be designed and certified by
RPEQ so as to support likely imposed loads and
Not cause or allow damage to adjacent building
works or land.

All boundary works, including temp. works not to
encroach over boundary.

Builder to make allowance to prop, shore and
retain the sides of all excavations required for
building construction, The builder shall satisfy
himself as to employ prior to commencing ‘any’
excavation. Any slippage or damage caused as
a result of excavation shall be made good by
builder. Adequate retention methods are the full
responsibility of the builder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1 SITE PLAN

 

\wo.101) ‘SCALE1:200 @ A2

SURFACE WATER
DRAINAGE

The ground beneath suspended floors must be
graded so that the area beneath the building is
above the adjacent extemal finished ground
level and surface water is prevented from
ponding under the building. Refer figure 3.1.2.3
of BCA 2007 Housing Provisions.

The extemal finished ground level surrounding
the building must be graded to a slope not less
than 50mm over the first 1.0m from the building
in accordance with Figure 3,1.2.2 of BCA 2007
Housing Provisions.

The finished ground level is to be a minimum of
150mm below ground floor level.

BUILDING WORKS
SETOUT

Building Works to be setout by Licensed
Surveyor.

Identification and height verification survey to be
cartied out once fascia/gutter and ridge to roof
has been erected to confirm no works encroach
boundaries and the building has been
constructed in accordance with approved plans
and height does

not exceed 9.0m height limit as per the local
planning scheme.

 

 

FLOOR AREAS ENERGY EFFICIENCY
2
KT DWE/LV 713° REQUIREMENT
BED 2 25 08m? Pro Therm “Reflecta Cell" 7mm insulation to be
BED3 25.08m? installed to all roof spaces (excluding decks) to
by TOTAL 146.54m? manufacturers direction.
; SITE COVER Pro Therm "Reflecta Shield’ 4mm insulation to

 

TERMITE PROTECTION

TERMITE PROTECTION

The building shall be protected from
subterranean termites by approved physical and/
or chemical bariers in accordance with
AS3660.1.

The precise method of protection shall be
determined by the owner/ s and/ or builder only
after consultation with a licensed pest contro!
operator.

This information then shall be advised to the
Local Government or Licensed Certifier prior to,
or at the time of lodgement of the Building Permit
Application.

Thereafter, the owners shall ensure that any
physical barriers are kept clear of garden beds
and/ or soil build up, that any chemical barriers
remain undisturbed and that annual inspections
(plus eradication as necessary ) are carried out
thoughout the life of the building by a licensed
pest control operator in accordance with
AS3660.1.

On the completion of the building prior to the
final inspection by the licensed Building Certifier,
a licensed Pest Controller is to inspect and
confirm that the termite system installed has not
been bridged or breached and the required
visual barrier has been maintained.

be installed to all exterior framed walls and
framed floors in accordance with manufacturer's
direction

All external doors and windows to be fitted with a
seal to restrict air infiltration

Hot water systems shall be fitted with a heat trap
within one metre of the outlet of the heater and
before the first branch.

All exhaust fans to conditioned spaces to be
fitted with a self closing damper.

SUB-FLOOR VENTILATION

Note: The subfloor space beneath the
suspended floor of a building must be designed
and constructed in accordance with Part 3.4.1.2
of BCA 2007 Housing Provisions.

WATER SUPPLY

Water Supply: Connect to estate mains in
accordance with development approval and local
authority requirements

If mains water pressure exceeds or could
exceed 500kPa, a water pressure limiting device
shail be installed to ensure that the maximum
operating pressure at any outlet within the
boundaries of the property does not exceed 500
kPa.

WATER PROOFING WET
AREAS

Waterproofing of wet areas to comply with
AS3740-2004. A certificate including bathrooms,
WC and laundry from an approved waterproofing
applicator will be required before a_ final
certificate can be issued.

STORMWATER

Roof & surface stormwater to be disposed of in
accordance with local authority requirements

BUILDING WORKS
SETOUT

Building Works to be setout by Licensed
Surveyor.

identification and height verification survey to be
carried out once fascia/gutter and ridge to roof
has been erected to confirm no works encroach
boundaries and the building has been
constructed in accordance with approved plans
and height does not exceed 9.0m maximum
height limit

SEWERAGE

Connection of house drains to sewer main to be
carried out in accordance with local authority
requirements

 

ARCHITECTURAL DRAWING SET

100 series dwg's - SITE PLANS

WD 101 - Cover Sheet / General Notes
WD 102 - Site Setout / Perspectives

200 series dwg's - PLANS

WD 201 - Sub Floor Basment Plan
WO 202 - Lift Landing Plan

WD 203 - Main Floor Plan

WD 204 - First Floor Plan

WD 205 - Second Floor Plan

300 series dwg's - CEILING PLANS

WD 301 -Main / First & Second Floor Plans

400 series dwg's - ELECT PLANS

WD 401 - Sub Floor Basement Plan and notes
WD 402 - Main / First & Second Floor Plans

500 series dwg's - ELEVATIONS

WD 501 - North and East elevation
WD 502 - South elevation
WD 503 - West elevation

600 series dwg's - SECTIONS

WD 601.- Sections A

700 series dwg's - DETAILS

WO 701 - Details Sheet 1
WD 702 - Details Sheet 2

800 series dwg's - JOINERY

WD 801 - Kitchen Details

WO 802 - Kitchen and Laundry PLAN

WD 803 - Ensuite 1 and 3
WD 804 - Bed 1,2 & 3 + Robes
WD 805 - Ensuite 2

900 - series - SCHEDULESpat

WD 901 - Window Schedule
WD 902 - Door Schedule

WALL & FLOOR LEGEND

&zzz4 RC Block

C“ Reinforced Concrete

<== Timber Framed Wall

fizz Finished Floor Level generally
s3s09 Structural Floor Level generally
+s.350 Spot Level

r3s0 Reduced Level

tow3s00 Top of Wall level

 

SIGNATURE:

kidd
+CO

designers

20 Duke Steet
‘Sunshine Beach QLD 4567

PO Box 262
Noosa Heads QLD 4567

07 5447 5633
07 5447 5833

Telephone
Facsimile

info@kiddeo com. au
www kidd0o.comn. bu
Tisdravngie obo
readin conncton wih
Engneors Drawgs &

NOOSA CUTE PAPC

oA

eVeD

HVaw.O}..,,.,

 

 

T1 PRICING ISSUE 6807
T2 ISSUE 20.00.07
Redocalion of

= fit shat

= driveway and relaining wals
= tumtable

+ i shaft roof height raised

13 ISSUE 09.10.07
Development approval issue

oe
Projeot
TREE HOUSE

Location
10 PARK ROAD
NOOSA HEADS

Clack

FIRST PICKED PTY
Drawing Tide
SITE PLAN
Sede Dae

as shown JAN 07
(Orawn By dob No,
SF 0703

Oraweng No. teu Ko.
WD.101 @)

Used in these records

About this file

File size
1.0 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

22441 DA - Approved Plans [As Published].pdf · 1.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.