   ¿ play your part - print on recycled paper                                                                                                                                                                                                                                                                                                                                                                                                                       5m         4          3         2          1

       Legend
        bv1         290 x 110 x 50mm Krause Empress
                    bricks installed in accordance with the
                    manufacturer's specifications with ‘Wet
                    Sponge Mortar” finish. : wet sponge
                    technique involves washing/smearing
                    the mortar joints using a wet sponge
                    during laying. System to be confirmed
                    with Krause and 1m sample panel
                    approved by client prior to
                                                                                                                                                                                                                                                                rbw
                    commencement.
        cl1         Timber cladding - Newport Century
                    Blackbutt (120 x 19mm) pre-finished                                30                   29                                  28                                                27                                26 25
                    cladding by Modinex installed to
                    manufacturer's specifications.                                                  3,600                     6,400                               10,390                                      6,000          1,000
        eg1         Custom folded gutters in 316 stainless
                    steel to be fixed in accordance with
                                                                                                                                                                                                                                                              eg1
                    manufacturers specifications. Gutters
                    to be in accordance with hydraulic
                    engineers design and detail. Inner
                    gutter to have fall to rwo wth external                                                                                                                                                                                                     Existing decking to be removed and structure inspected by
                    gattuer flashing flush to soffit.                                                                 rs1                                                                                                                                       the structural engineer to verify condition. Provide 140mm
        rbw         Concrete block wall to be in                                                                                                                                    rs1                                                                         Accoya decking with s/s screw fixing to structure. Decking
                    accordance with structural engineers                                                                                                                                                                                                        shall be installed in accordance with Timber Queensland
                    design and detail. Wall to be finished                                                                                                                                                                                                      Technical Data Sheet 13.
                    externally with acrylic render system
                    with fine sand finish and painted.
                                                                                                                                                                                                                                                                Timber framed stairs/decking to have h4 treated timber
        rs1         Standing seam Prefa Aluminium to be                                                                                                                                                                                  cl1                    structure in accordance with structural engineers design and
                    fixed in accordance with manufacturers                        sw        cl1                                           cl1     bv1       bv1            bv1                bv1       cl1           cl1
                    specifications. Provide plywood                                                                                                                                                                                                             detail. Provide 140mm Accoya decking with s/s screw fixing to
                    substrate.                                                                                                                                                                                                                                  structure. Decking shall be installed in accordance with
                                                                                                                                                                                                                                                                Timber Queensland Technical Data Sheet 13.
        sw          Selected feature stone facing installed
                    in accordance with manufactuers
                    specificaitons.




                                                                                       30                   29                                  28                                                27                                26 25




                                                                    Gym North Western Elevation
                                                               NW                                 1:100




                                                                                                                 Z                              Y                      X             W              V
                                                                                                                                  5,700                 5,990               2,600         2,000


                                                                                                                                                                                                                       eg1
                                                                                                                             20.0°
                                                                                                                                                                                                                       Existing decking to be removed and structure inspected by
                                                                                                                                                                                          20.0°                        the structural engineer to verify condition. Provide 140mm
                                                                                                                                                                                                                       Accoya decking with s/s screw fixing to structure. Decking
                                                                                                                                                          cl1               rbw                                        shall be installed in accordance with Timber Queensland
                                                                                                                                                                                                                       Technical Data Sheet 13.

                                                                                                                            rbw                                            rbw
                                                                                                                                                rbw                                                                    Timber framed stairs/decking to have h4 treated timber
                                                                                                                                                                                                                       structure in accordance with structural engineers design and
                                                                                                                     rbw                                                            bv1                                detail. Provide 140mm Accoya decking with s/s screw fixing to
                                                                                                                            sw
                                                                                                                                                                                                                       structure. Decking shall be installed in accordance with
                                                                                                                                                                                                                       Timber Queensland Technical Data Sheet 13.




                                                                                                                 Z                              Y                      X             W              V




                                                                    Gym North Eastern Elevation
                                                               NE                                 1:100




                                                                                                                                                                                                                                                                                                                                                                                                                                           NOOSA COUNCIL
                                                                                                                                                                                                                                                                                                                                                                                                                                           APPROVED PLAN
                                                                                                                                                                                                                                                                                                                                                                                                                                     MCU26/0012.01 & OPW26/0034.01
                                                                                                                                                                                                                                                                                                                                                                                                                                         22 SEPTEMBER 2026
                                                                                                                                                                                                                                                                                                                                                                                                                                                              /Users/benthornton/Documents/Cadfiles/2403 - Blake/Archicad/
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       01092026/2403.pln
                                sbt designs pty ltd t/a
                                Skale Building Design                                                                                                                                                                                                                                                                           project   Residence              lot no.                2   DA05   Amended DA issue                                1/9/2026
                                                                                                                                                                                                                                                                                                                                                                                                                                                              project number
                                Mobile: 0412 025 657
                                                                                                                                                                                                                                                                                                                                for       Cameron & Jane Blake   plan no.          214048   DA04   Amended development application                22/7/2026
                                                                                                                                                                                                                                                                                                                                                                                                                                                              2403
   skale
      building
Document   Set design
               ID: 25133621
                                skale.com.au
                                [email protected]
                           A.C.N. 123 976 296 QBCC: 1143 609                                                                                                                                                                                                                                                                    at
                                                                                                                                                                                                                                                                                                                                          111 Lukes Road
                                                                                                                                                                                                                                                                                                                                          Cooroy Mountain
                                                                                                                                                                                                                                                                                                                                                                 drawn
                                                                                                                                                                                                                                                                                                                                                                 scale      (A1)
                                                                                                                                                                                                                                                                                                                                                                                      BT
                                                                                                                                                                                                                                                                                                                                                                                    1:100   Rev    Details                                            Date
                                                                                                                                                                                                                                                                                                                                                                                                                                                              drawing number
                                                                                                                                                                                                                                                                                                                                                                                                                                                              12           DA05                    © Skale Building Design
Version: 1, Version Date: 04/09/2026

Used in these records

About this file

File size
20.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approvred Plans - MCU26_0012.01 & OPW26_0034.01 (As Published).pdf · 20.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.