Original source · versioned page text
Appendix A - Code Assessment
Performance outcomes Acceptable outcomes Compliance
day to day water supply. millimetres in diameter and fitted
with a standard fire brigade fitting
connected to the water supply
(other than where the water
supply is in a swimming pool or
dam).
PO16 AO16.1 Not Applicable
Development is designed and Where the development is Site is not within flood.
sited to ensure risk to people and located in the Flood Hazard Area
property from flooding is avoided as shown on Flood Hazard
or minimised. Overlay Map in Schedule 2, the
finished floor level of habitable
rooms is at least 300 millimetres
above the Defined flood event
(DFE).
AO16.2 Not Applicable
Where the DFE has not been Site is not within flood.
modelled for the area, the
finished floor level of habitable
rooms is at least 500 millimetres
above the highest recorded flood.
PO17 AO17 Not Applicable
Underground car parking areas No acceptable outcome provided Site is not within flood.
are designed to drain and
function safely during a flood
event and power failure.
PO18 AO18.1 Not Applicable
Development is sufficiently Development including any Site is not within these areas.
separated from major electricity sensitive land uses is at least:
infrastructure and substations to 50 metres from a transmission
minimise the likelihood of substation;
nuisance or complaint. 10 metres from any other
substation; and
30 metres from a transmission
line easement.
PO19 AO19 Complies
Development is located and Noise emissions do not exceed Development Complies
designed to avoid or minimise 5db(A) above background noise
noise nuisance from the use of level internal to a habitable
infrastructure. building measured in accordance
with AS1055.
PO20 AO20 Complies
Wherever practicable habitable Where adjoining substations or Development Complies
buildings are orientated to avoid major electricity infrastructure,
direct overlooking of major habitable buildings are orientated
electricity infrastructure or so that the majority of outdoor
substations. living areas and windows of
habitable rooms face away from
the infrastructure.