14. APP I. SPP Code - Water Quality
Attached to the e-mail MCU14/0102 Development Application 4 of 4 App H Engineering, App I Water quality, App J Economic Needs, App K Local Code response..
Performance outcomes Acceptable outcomes Response Comment
PO2 Development does not AO2.1 A wastewater management plan NA The proposal will not be supported by a
discharge wastewater to a (WWMP) is prepared by a suitably qualified wastewater management plan given that it will
waterway or off site unless person and addresses: not relate to the discharge of aqueous waste. The
demonstrated to be best a. Wastewater type, and proposal is however supported by a Stormwater
practice environmental Management Plan which details appropriate
b. Climatic conditions, and
management for that site. stormwater quality treatment measures.
c. Water quality objectives (WQOs), and
d. Best-practice environmental
In regards to oily water discharge from the service
management, and
station component refuelling area, a suitably
qualified hydraulic consultant will be engaged at
the Building Works stage to design the fuel
dispensing area in accordance with AS1940.
AO2.2 The WWMP provides that wastewater is NA See above response.
managed in accordance with a waste
management hierarchy that:
a. Avoids wastewater discharges to
waterways, or
b. If wastewater discharge to waterways
cannot practicably be avoided,
minimises wastewater discharge to
waterways by re-use, recycling,
recovery and treatment for disposal to
sewer, surface water and groundwater
PO3 Any non-tidal artificial AO3.1 If the proposed development involves a NA The proposal is not related to a non-tidal artificial
waterway is located in a way that non-tidal artificial waterway: waterway.
is compatible with the land use a. Environmental values in downstream
constraints of the site for waterways are protected, and
protecting water environmental
b. Any groundwater recharge areas are
values in existing natural
not affected, and
waterways.
c. The location of the waterway
incorporates low lying areas of a
catchment connected to an existing
waterway, and
SPP Code 3: Water Quality 14124 – Empirica Developments Pty Ltd Page 2