14. APP I. SPP Code - Water Quality

Attached to the e-mail MCU14/0102 Development Application 4 of 4 App H Engineering, App I Water quality, App J Economic Needs, App K Local Code response..

of 9

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

 Performance outcomes                Acceptable outcomes                                   Response        Comment
 PO2 Development does not            AO2.1 A wastewater management plan                         NA         The proposal will not be supported by a
 discharge wastewater to a           (WWMP) is prepared by a suitably qualified                            wastewater management plan given that it will
 waterway or off site unless         person and addresses:                                                 not relate to the discharge of aqueous waste. The
 demonstrated to be best                a. Wastewater type, and                                            proposal is however supported by a Stormwater
 practice environmental                                                                                    Management Plan which details appropriate
                                        b. Climatic conditions, and
 management for that site.                                                                                 stormwater quality treatment measures.
                                        c. Water quality objectives (WQOs), and
                                        d. Best-practice environmental
                                                                                                           In regards to oily water discharge from the service
                                           management, and
                                                                                                           station component refuelling area, a suitably
                                                                                                           qualified hydraulic consultant will be engaged at
                                                                                                           the Building Works stage to design the fuel
                                                                                                           dispensing area in accordance with AS1940.
                                     AO2.2 The WWMP provides that wastewater is                 NA         See above response.
                                     managed in accordance with a waste
                                     management hierarchy that:
                                        a. Avoids wastewater discharges to
                                           waterways, or
                                        b. If wastewater discharge to waterways
                                           cannot practicably be avoided,
                                           minimises wastewater discharge to
                                           waterways by re-use, recycling,
                                           recovery and treatment for disposal to
                                           sewer, surface water and groundwater


 PO3 Any non-tidal artificial        AO3.1 If the proposed development involves a               NA         The proposal is not related to a non-tidal artificial
 waterway is located in a way that   non-tidal artificial waterway:                                        waterway.
 is compatible with the land use        a. Environmental values in downstream
 constraints of the site for               waterways are protected, and
 protecting water environmental
                                        b. Any groundwater recharge areas are
 values in existing natural
                                           not affected, and
 waterways.
                                        c. The location of the waterway
                                           incorporates low lying areas of a
                                           catchment connected to an existing
                                           waterway, and


SPP Code 3: Water Quality                                       14124 – Empirica Developments Pty Ltd                                                       Page 2
                                                      139 Eumundi Noosa Road & 30 Lionel Donovan Drive, Noosaville
Log in to download the original file

14. APP I. SPP Code - Water Quality.pdf · 228 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.