    NOTE:

    LOCATION AND SIZE OF DOWNPIPES TO BE
    CONFIRMED WITH PLUMBER ON SITE PRIOR
    TO INSTALLATION OF STORMWATER SERVICE


                                                                            DP                                        DP                          DP




                                                                                                                           O/H
                                                                                                                           300
                                                        300                                                                                                  300
                                                        O/H                                                                                                  O/H




                                                                                                                 7.5°
                                                                                                                                                                        DOWNPIPES
                                                                                                                                                                        Locality:                                      Sunrise Beach, QLD
                                                                                                                                                                        Rainfall intensity 20 year ARI:                259mm/h
                                                                                                                                                                                                                       259

                                                                                                                                                                        Roof plan catchment area:                      151.43 m2
                                                                                                                                                                        Roof raked catchment area:                     162.03 m2
                                                                                                                                                                        Eaves Gutter:                                  7300 mm2




                                                                                                                                    1300
                                                                                                                                                                        Slope 1:500                                    Yes
                                                                                                                                                                        Downpipe size:                                 ⌀100mm
                                                                                                                                                                        No of Downpipes required:                      3




                                                                    PROPOSED - ROOF PLAN                                                                                DP - INDICATES UPVC DOWNPIPE. UVC STROMWATER
                                                                                                                                                                             LINE TO CONNECT INTO RAINWATER
                                                                    SCALE            1 : 100
                                                                                                                                                                             COLLECTION TANK & STROMWATER SYSTEM IN
                                                                                                                                                                             ACCORDANCE WITH LOCAL AUTHORITY
                                                                                                                                                                             REGULATIONS. PROVIDE 1 IN 100 MINIMUM FALL.




AAA Design & Development Pty Ltd                                             No.                        Description               Date        Mat Deighton                          APPROVED                    Proposed - Roof Plan

34/13 Norval Court, MAROOCHYDORE, QLD 4558                                                                                                    14 Orealla Cres,                                                  Project number      D139-01                     Revision
Tel/Fax:       (07) 5479 6747                                                                                                                 SUNRISE BEACH, QLD 4567                                           Date             24/08/2022    3951- A111
Mob:           0422 039 247
                                             design                             B      Client Change                            30/08/2022                                                                     Drawn by                R.S.                       B
email:         [email protected]          Development Pty Ltd                                                                         PROPOSED DUAL OCCUPANCY            For & on behalf of AAA
                                                                                                                                                                              Design & Development Consulting   Checked by            D.L.T. Scale @A3      As indicated
                                                                                 A      PRELIMINARY                              24/08/2022
Log in to download the original file

Attachment 1 - Proposal Plans.pdf · 16.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.