Log in to see the plans as drawn DRAWINGS SHALL BE READ IN CONJUNCTION WITH RELEVANT ENGINEERS DESIGN AND DETAILS
300 Weathertex Selflok 300mm 300
O/H or Equivalent Weatherboards. O/H
Colour - Surfmist
FCL 40.300
7290 MAX Height
Joinery
Joinery
2400
2100
1000
FFL 37.900
to Btm Beam
1000H Min Balustrades
2900
2380
to Client Selection
FFL 35.000
Natural Ground Stair Construction Riser Max 190mm Timber Latice Fixed In
Line Going 240 Min 900H Balustrade Between Posts As Indicated
Above Nosing Line
PROPOSED - ELEVATION 1
SCALE 1 : 100
NOTES
1. Glazing b) External walls are to be covered with sisalation and are to have a minimum of R1.5 b) Energy conservation
All glass windows and doors are to comply with Australian Standard 2047 insulation. - Energy efficient lighting requirement applies to all new houses,
and or 1288-1990. c) The roof is to a minimum of medium weight sisalation and a minimum of R2.5 townhouses their enclosed attached garage or carport.
insulation. - Light fittings must be energy efficient to a min. of 80% of the
2. Waterproofing d) The R value in bulk insulation is reduced if compressed at the time of insulation. It total fixed internal lighting.
The waterproofing of wet areas is to be installed in accordance with AS is recommended that adequate space be allotted for the installation of the insulation. - This requirement also applies to existing dwellings when
3740. undertaking alterations and additions or relocations.
4. Sustainable Housing
3. Energy Efficiency Climate Zone 2 All Class 1 building work must comply with the Queensland Development Code Part 29
a) With regard to the Energy Efficiency requirements of BCA 3.12.5, the hot Sustainable Building.
water supply system shall be designed and installed in accordance with a) Water conservation
Section 6A of AS/NZS 3500.4.2, or AS/NZS 3500.5, except if a solar hot - Toilets - min. 4 star WELS rated.
water supply system is installed. - Tapware - min. 3 star WELS for kitchen sink, basins and laundry trough. ALL INTERNAL & EXTERNAL COLOURS & FINISHES TO CLIENT SELECTION
- Showerheads - min. 3 star WELS
AAA Design & Development Pty Ltd No. Description Date Mat Deighton APPROVED Proposed - Elevation 1
34/13 Norval Court, MAROOCHYDORE, QLD 4558 14 Orealla Cres, Project number D139-01 Revision
Tel/Fax: (07) 5479 6747 SUNRISE BEACH, QLD 4567 Date 24/08/2022 3951- A107
Mob: 0422 039 247
design B Client Change 30/08/2022 Drawn by R.S. B
email: [email protected] Development Pty Ltd PROPOSED DUAL OCCUPANCY For & on behalf of AAA
Design & Development Consulting Checked by D.L.T. Scale @A3 As indicated
A PRELIMINARY 24/08/2022