NOOSA COUNCIL IDAS Development Application Decision Notice                                                     4 of 8


Environmental Health
11.    The developer must provide waste storage and disposal facilities in accordance with Planning Scheme
       Policy No. 9 “Waste Management Multi-Dwellings and Commercial and Industrial Premises”, including an
       external imperviously paved area correctly sized for all refuse and recycling containers and suitably
       screened from public places and neighbouring properties. A bin wash area is required with a cold-water
       tap, hose & drain outlet connected to sewer, via a bucket trap. The drain outlet is to be designed to
       prevent storm water entry to the sewerage system and this can be achieved with a nib wall 50mm high
       and up to 700mm x 700mm (max 0.5m²), the waste area can be roofed, or any other design approved by
       Council.

12.    A clinical waste service provided by a licensed clinical waste contractor must be provided for the activities.

13.    Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool pumps etc)
       shall comply with the following requirements:
       The equipment shall be installed and located in a manner that prevents excessive noise in accordance
       with Council’s Local Law No. 12 - Control of Nuisances. Infringement Notices (on-the-spot fines) may
       apply for offences.
       A person must not use equipment on any day if it makes or causes noise to be made –
       From 10pm to 7am: More than the lower of either –
            40 dB(A)

            3 dB(A) above the background noise level

            No audible noise for pool pumps applies during these hours.
              From 7am to 7pm: More than the lower of either –
            50 dB(A)

            5 dB(A) above the background noise level

       From 7pm to 10pm: More than 3 dB(A) above the background noise level.

14.    Submission of written certification from a suitably qualified person confirming that the noise levels from all
       mechanical equipment comply with the cause above when measured at either the residential boundary or
       outside the most exposed part of an affected building, whichever is the closest to the equipment.
      The assessment and certification is required immediately after installation of the equipment and prior to
      any occupation of the building, and in a format approved by Council. This assessment must take into
      account noise from any other fixed equipment on the property e.g. swimming pool pump, heating/cooling
      equipment, etc that may increase the overall noise level emitted.
      Advice: It is highly recommended that the person you engage to certify the installation is involved at the
      plan development stage so they can recommend where this equipment is best located. They can also
      advise about noise enclosures and can make other suggestions to avoid noise problems. It is a lot more
      costly to try and deal with noise problems after everything is built.

15.    Noise from building works associated with residential development shall comply with the following –

       15.1. Limited to between 7:00am to 6:30pm Monday to Saturday.

       15.2. All reasonable measures are taken to minimise noise emissions.

       15.3. Not permitted on Sunday or public holidays.

16.    All liquid waste produced by the commercial section of the development is “Trade Waste” and is to be
       treated as required under the Noosa Trade Waste Policy prior to release to the sewer.

17.    The hydraulic drawings are to show all the Trade Waste requirements in accordance with the Noosa
       Trade Waste Policy. NB: A Trade Waste Permit must cover all types of Trade Waste discharged.

18.    A Trade Waste Application must be submitted prior to the issue of a Development Permit for Building
       Works.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@e007516c\@[email protected]

Used in these records

About this file

File size
38 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

001593D9.001.pdf · 38 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.