Original source · versioned page text
Appendix D - Bushfire Risk Assessment and Management Plan
Ecological Natural Area Management
5 Bushfire risk assessment
5.1 Assessment of the Potential Bushfire Intensity Class
As required by State Planning Policy 2017, this report will use the the protocol specified in A new
methodology for state-wide mapping of bushfire prone areas (Leonard et al, 2014) to assess the
bushfire prone area status of the development.
This methodology uses the following parameters.
• Potential Fuel Load
This is derived from Vegetation Hazard Classes table in the protocol. The table was derived
by relating vegetation community derived by combining Remnant Vegetation Regional
Ecosystem types and their Fire Regime Groups developed by the Queensland Parks and
Wildlife Service (Neldner et al, 2012) to a potential fuel load using the methodology of the
Overall Fuel Hazard Assessment Guideline .
• Patch and corridor filtering
Patch and corridor filtering can be used to remove or downgrade hazard levels of small
patches of vegetation and narrow corridors.
• Maximum Landscape Slope
The Maximum Landscape Slope is derived for 25m pixel separations.
• Fire Weather Severity
An expected McArthur Forest Fire Danger Index using a 1:20 year or 5% annual
exceedance probability was derived for all areas in Queensland to reflect the severity of
bushfire events suited to mitigation through land use planning and this expected maximum
FDI is presented in as a map in Figure 16: Fire weather severity for Queensland in A new
methodology for state-wide mapping of bushfire prone areas (Leonard et al, 2014). The
Forest Fire Danger Index for this site in Figure 16 is FFDI = 50.
• Potential Fire-line Intensity
With the above inputs, a Potential Fire-line Intensity can be calculated using the formula:
PFI = 0.62 x PFL2 x FFDI x exp(0.069 x slope)
Where:
PFI = Potential Fireline Intensity
PFL = Potential Fuel Load
FFDI = Expected maximum Forest Fire Danger Index
Slope = Maximum 25m pixel slope in degrees
Bushfire Risk Assmnt & Mngt Plan for a “Community housing” development at 55 Carpenters Rd, Cooroy February 2022