Original source · versioned page text
Appendix D - Bushfire Risk Assessment and Management Plan
Ecological Natural Area Management
5.4 Tabulation of the Potential Bushfire Intensity Class
Table 4: Tabulation of the potential bushfire intensity classes for each of the patches
Patch Vegetation class Fuel load Slope FDDI Fireline Intensity Potential Bushfire
Intensity Class
Patch 1 VHC 9.1 Moist to dry 24.2 t/ha 5.7 0 53 28538 kW/m High
eucalypt open forests
on coastal lowlands
Patch 2 Discontinuous low 3 t/ha 3.4 0 53 374 kW/m Low
grass or tree cover
Patch 3 Discontinuous low 3 t/ha 3.4 0 53 374 kW/m Low
grass or tree cover
Patch 4 Discontinuous low 3 t/ha 4.3 0 53 397 kW/m Low
grass or tree cover
Patch 5 Discontinuous low 3 t/ha 2.5 0 53 351 kW/m Low
grass or tree cover
Patch 6 VHC 9.1 Moist to dry 24.2 t/ha 2.5 0 53 22885 kW/m High
eucalypt open forests
Patch 7 on
VHCcoastal lowlands
39.2 Low to 8 t/ha 3.9 0 53 2756 kW/m Low
moderate tree cover in
Patch 8 built-up
VHC 3.1areas
Notophyll vine 4.5 t/ha 1.4 0 53 733 kW/m Low
forest
Patch 9 VHC 9.1 Moist to dry 24.2 t/ha 1.4 0 53 21202 kW/m High
eucalypt open forests
on coastal lowlands
5.5 Potential Impact Buffer
As analysis of heat radiation decay curves and national research indicating that in most fires over
80% of housing loss and 80% of human life loss has occurred within 100m of bushland (Leonard et
al., 2014, page 7) specify that a default 100 meter buffer from the edge of hazardous vegetation
which has a Medium, High or Very High Potential Bushfire Intensity Class.
Bushfire Risk Assmnt & Mngt Plan for a “Community housing” development at 55 Carpenters Rd, Cooroy February 2022
18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Appendix D - Bushfire Risk Assessment and Management Plan.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.