Appendix D - Bushfire Risk Assessment and Management Plan

of 40
                         Ecological Natural Area Management


Recommendations
Recommendations for the Noosa Plan Bushfire Overlay Code
It is recommended that notwithstanding that the development is located in a Potential Bushfire Impact
area, the development maintains the safety of people and property from the adverse impacts of
bushfire by maximising setbacks from hazardous vegetation to achieve an acceptable risk as:
     • Both new lots could have houses constructed to BAL 12.5 construction standard,
    •    Houses can be sited in a low hazard area in the lot and achieve a setback of 10 metres
         from any retained vegetation,
    •    Houses will have a reliable reticulated water supply for fire fighting purposes
    •    Expected Radiant Heat loads at each house is less than 10kW/m2 and
    •    The escape route is through a safe area with expected radiant heat less then 10kW/m2,
    •    The development does not result in a material increase in the extent and severity of
         bushfire hazard,
    •    The development supports and does not unduly burden disaster management response or
         recovery capacity and capabilities as there are escape routes through a safe areas with
         expected radiant heat less then 10kW/m2,
    •    No bushfire mitigation measures such as vegetation clearing that could adversely impact
         biodiversity values are required.
Recommendations for Australian Standard AS3959
Australian Standard AS3959 Construction of buildings in bushfire-prone areas specifies Deemed to
Satisfy bushfire resistant methodologies based on the assessed Bushfire Attack Level.
It is recommended that:
    •    The building solution for all building elevations for any houses in the lots to address the
         Deemed to Satisfy requirements of Sections 3 and 5 of Australian Standard AS3959-2018
         Construction of buildings in bushfire-prone areas
Other recommendations for building siting and landscaping
It is recommended that:
    •    The buildings to have a bushfire fuel free zone around the house,
    •    The buildings be constructed with a minimum of lodgement points for burning debris and
    •    On-going maintenance of the buildings be conducted.
See Sections 8.4, 8.5 and 8.6 of this report
Recommendations for Part E: Natural hazards of the Queensland State Planning Policy 2017
It is recommended that, notwithstanding the developmenti in an area of Potential Bushfire Hazard:
    •    The building siting, construction, firefighting resources etc appropriately mitigates the
         potential bushfire Hazard as required by the SPP
    •    The development does not unduly burden emergency services as there is good access for
         firefighting appliances, good fire fighting space, good water supply and contributes only one
         extra building in the emergency services area
    •    The building and the cleared and hard-standing areas decreases the severity of a bushfire
         on the lot and therefore does not increase severity of the bushfire Hazard and,
    •    There will be no hazardous material stored on the lot.

Bushfire Risk Assmnt & Mngt Plan for a “Community housing” development at 55 Carpenters Rd, Cooroy   February 2022

                                                              7

Log in to download the original (Appendix D - Bushfire Risk Assessment and Management Plan.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.