Rfi - Attachment E - Acoustic Report
Decibell
dB Consulting pty Ltd
Proposed Multi-residential Development
101-105 Eumundi Road,
Noosaville
ENVIRONMENTAL
NOISE IMPACT REPORT
Prepared for
Altum Constructions
9th February 2021
Decibell Report No.: 2102318
Decibell Consulting Pty Ltd
30 Albert St,
Woolloongabba QLD 4102
t (07) 3391 5096
m 0415581632
e [email protected]
ABN 77 108 203 998
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 41 pages
Page 2
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Contents
Page
1.0 Introduction …………………………………………………………………………….…3
1.1 The Proposal………………………………………………………………………………...………....3
2.0 Equipment ………………………………………………………………………………...3
3.0 Measurement Procedure ………………………………………………………………..4
4.0 Noise Criteria………………………………………………………………………………5
4.1 Noise impacts from Surrounding Noise Sources on the Proposed Development ………….….…..5
4.2 Noise from Onsite activities ……………………………………………………………….………………7
4.3 Transport Noise Corridors………………………………………………………………………….….…..8
5.0 Results and Calculations…………………………………………………………………9
5.1 Background and Ambient Noise levels………………………………….………….……………..…….9
5.2 Background Creep Criteria………………………………….………….…………………………..……10
5.3 Pool Area Source levels………………………………….………….……………………………..……10
5.4 Background Creep Assessment ………………………………….………….…………………...……11
6.0 Recommended Acoustic Treatments ………………………………………………… 12
6.1 Noise impacts from Surrounding Noise Sources on the Proposed Development ……..…..……..12
6.2 Noise impacts from Pool Area……..……………………………………………………………………..14
7.0 Discussion & Conclusions………………………………………………………..…….16
APPENDIX……………………………………………………………………………………17
Decibell Report No. 2102318 Page 2
Page 3
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1.0 INTRODUCTION
This report is submitted in response to a request by JFP Urban Consultants, on behalf of the Altum
Constructions, for an environmental noise impact assessment of a proposed multiple dwelling development
to be located at 101-105 Eumundi Noosa Road, Noosaville. This report seeks to supply the Information
Requested in Section 14 of the Information Request issued by the Noosa Shire Council in relation to the
th
development on the 12 January 2021.
On-site noise logging and attended noise measurement were conducted, and through modelling, predictions
of noise impacts from the development on the neighbouring residences have been produced. Based upon
these predicted levels, recommendations regarding acoustic treatments and management practices have
been specified.
1.1 The Proposal
The proposal is for a multiple dwelling development to be located on a vacant site at 101 and 105 Eumundi
Noosa Rd, Noosaville. The development will consist of 34 apartments; 28 two bedroom apartments and 6
three bedroom apartments.
The development will be located in a predominantly residential area. However a small commercial centre is
located to the north of the site as well as a storage yard to a scaffolding business to the east. Nosie impacts
from the businesses have the potential to impact on the proposed development and will be considered in this
report.
As part of the development a pool area will be located in the south eastern corner of the site. This area will
be used by future residents of the development and guests. As the area is located adjacent to the
neighbouring residential area noise impacts have the potential to affect the neighbouring dwellings to the
site. Given this noise impacts from this area will be considered in this report.
For further details of the development layout and surrounds refer to appendix for site plans and aerial
photograph.
2.0 EQUIPMENT
2.1 Noise Assessment
The following equipment was used to record noise impacting onto the site:
• Bruel Kjaer 4231 Calibrator;
• Rion Nl 21 Environmental Noise Logger.
• Rion NA 27 Sound Level Meter.
Decibell Report No. 2102318 Page 3
Page 4
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
3.0 MEASUREMENT PROCEDURE
3.1 Logger Noise Measurement
A noise logger was located on site adjacent scaffolding business at the rear of the site and commercial
business north of the site. The location of the logger is indicated on the aerial photograph included below.
Logger Measurement
Location
Figure 1: Measurement Location
The logger was set to record noise statistics in 15 minute blocks continually over an 168 hour period from
Thursday the 7/01/21 to Thursday 14/01/21. Ambient noise level measurements were conducted generally
in accordance with Australian Standard AS1055 2018 “Acoustics – Description & Measurement of
Environmental Noise”.
The operation of the sound level measuring equipment was field calibrated before and after the
measurement session and was found to be within 0.1 dB of the reference signal. All instrumentation used in
this assessment hold current calibration certificate from a certified NATA calibration laboratory.
Weather conditions during the survey period included rain periods over the weekend of Saturday the 9th and
th
Sunday the 10 of January; these periods have been excluded from the measurement data. During the
logging period temperatures ranged from 19 ˚ C to 29˚ C.
Decibell Report No. 2102318 Page 4
Page 5
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
4.0 NOISE CRITERIA
4.1 Noise impacts from Surrounding Noise Sources on the Proposed Development
SC6.2.4 Appendix 1 - Requirements for technical assessments and reports of the Noose Shire Plan 2020 set
out the requirements for various technical reports including acoustic assessment reports. This section of the
Noose Shire Plan 2020 states an acoustic assessment report may be required if:
An acoustic assessment report may be required where a proposed development is likely to cause noise
impacts or where a proposed development site is located in close proximity to a land use or infrastructure
which may cause noise impacts on the proposed development (often referred to as reverse amenity
impacts).
In relation to the proposed development it is located in proximity to a number of commercial businesses to
the north and a storage yard for a scaffolding business to the east. Noise impacts from these businesses on
the proposed development will be considered in line with requirements for technical reports from the Noose
Shire Plan 2020. In addition to this noise impacts from the pool area on the neighbouring residential area
and internal vehicle movements on some bedrooms will also be considered.
SC6.2.4 Appendix 1 - Requirements for technical assessments and reports of the Noose Shire Plan 2020
states that acoustic assessment report should have regard to the following standards when assessing noise
imapcts:
1. Australian Standards AS 1055.2 Acoustics – Description and measurement of environmental noise –
Application to specific situations and AS 2107 Acoustics – Recommended design sound levels and
reverberation times for building interiors;
2. Environmental Protection Act 1994 and Environmental Protection (Noise) Policy 2008 (EPP Noise);
3. Noise Measurement Manual Department of Environment and Heritage Protection 2013
4. Road Traffic Noise Management Code of Practice, Department of Transport and Main Roads, 2008.
In order to assess the noise impacts from the surrounding businesses on the proposed development
reference will be made to Australian Standard AS 2107 Acoustics – Recommended design sound levels and
reverberation times for building interiors and the Environmental Protection (Noise) Policy 2008 (EPP Noise).
Australian/New Zealand Standard AS/NZ 2107- Recommended Design Sound Levels and Reverberation
Times for Building Interiors contains internal design sound levels for buildings of various types. Section 7 of
Table 1 of this standard contains the design sound level for residential buildings. This section of the standard
has been reproduced over the page.
Decibell Report No. 2102318 Page 5
Page 6
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Item Type of Occupancy / Activity Design Sound Level, LAeq, Desing reverberation
dB(A) Range Time Range Sec
Houses and apartments near major
7 roads –
Apartment common areas (e.g. foyer, lift 45 to 50 -
lobby)
-
Living areas 35 to 45
-
Sleeping areas (night time) 35 to 40
-
Work areas 35 to 45
Table 1: Internal noise limits for residential dwellings from Australian/New Zealand Standard AS/NZS
2107:2000 ‘Acoustics - Recommended design sound levels and reverberation times for
building interiors
Schedule 1 of the Environmental Protection (Noise) Policy 2008 (EPP Noise) also contains Acoustic Quality
Objectives relating to the indoor noise levels within dwellings. This section of the policy has been reproduced
below:
Decibell Report No. 2102318 Page 6
Page 7
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Comparing the two standards it can been seen that the Acoustic quality Objectives for the Environmental
Protection (Noise) Policy 2008 (EPP Noise) relating to internal noise levels within dwellings are the same or
less that those from Australian Standard AS 2107 Acoustics – Recommended design sound levels and
reverberation times for building interiors. Given this the Acoustic quality Objectives for the Environmental
Protection (Noise) Policy 2008 (EPP Noise) will be used to assess noise impacts from the surrounding
commercial properties on the development in this report. In order to satisfy the requirements of the
Environmental Protection (Noise) Policy 2008 (EPP Noise) a series of acoustic treatments will be applied to
the dwellings in order to achieve the internal Acoustic quality Objectives.
4.2 Noise from On Site Activities
A pool area will form part of the development. This area will be located on the south-east corner of the site.
Noise from the pool area could impact neighbouring residential properties. In order to assess the noise
impacts on these neighbouring properties in accordance with recommendations of SC6.2.4 Appendix 1 -
Requirements for technical assessments and reports of the Noose Shire Plan 2020 reference will again be
made to the Environmental Protection (Noise) Policy 2008 and more specifically the Background Creep
Criteria.
The Environmental Protection (Noise) Policy 2008 Background Creep Criteria relate noise impacts generated
by a noise source to existing background (LA90T ) noise levels at the receiver. The Environmental Protection
st
(Noise) Policy was reviewed in 2008 with the new policy commencing on the 1 January 2009. The
recommended criteria from Part 4 of this policy in relation to Background Creep are:
(2) To the extent that it is reasonable to do so, noise from an activity must not be –
(a) For noise that is continuous noise measured by LA90T – more than nil dB(A) greater than
the existing acoustic environment measured by LA90T ; or
(b) For noise that varies over time measured by LAeqT – more than 5 dB(A) greater than the
existing acoustic environment measured by LA90T ;
In this report Decibell Consulting will firstly measure the existing background (LA90T ) noise levels at the
receiver and then apply the above Background Creep criteria from Environment Protection (Noise) Policy
2008 to the predicted noise impacts from the proposed development.
Decibell Report No. 2102318 Page 7
Page 8
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
4.3 Transport Noise Corridors
The State Planning Interactive Mapping system can be used to identify properties that lie within Transport
Noise Corridors with respect to road and trail traffic noise. A portion of the mapping associated with this Tool
showing the site and traffic and rail noise levels has been reproduced below.
Figure 2: Transport Noise Corridor Mapping- Traffic Noise
It can be seen that the site is located outside any Transport Noise Corridor. Due to this fact no assessment of
traffic or rail noise impacts on the site will be undertaken in this report.
Decibell Report No. 2102318 Page 8
Page 9
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
5.0 RESULTS & CALCULATIONS
5.1 Background and existing Noise levels
Background and existing noise impacts from the surrounding commercial area including the Bell St were
recorded at the site. The Table below presents measured background noise levels and existing noise
impacts at this location.
Time of Day LA90 1hr LAeq 1hr LA10 1hr LA1 1hr
Day
(7.00 am – 6.00 pm) 48.9 53.3 55.4 59.3
Evening
Monday 11/01/21 (6.00 pm – 10.00 pm) 46.5 48.8 50.1 55.2
Night
(10.00 pm – 7.00 am) 36.7 44.8 47.1 52.0
Day
(7.00 am – 6.00 pm) 49.0 53.4 55.3 59.1
Evening
(6.00 pm – 10.00 pm) 42.7 48.6 50.6 55.3
Tuesday 12/01/21
Night
(10.00 pm – 7.00 am) 38.4 44.9 46.8 51.5
Day
(7.00 am – 6.00 pm) 48.2 53.1 54.9 59.3
Evening
Wednesday 13/01/21 (6.00 pm – 10.00 pm) 43.1 48.9 50.8 55.2
Night
(10.00 pm – 7.00 am) 37.2 44.2 46.1 51.6
Day
Thursday 14/01/21 (7.00 am – 6.00 pm) 46.1 51.8 53.9 58.5
Table 1: Measured noise levels on-site
Decibell Report No. 2102318 Page 9
Page 10
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
5.2 Background Creep Criteria
Based on the measured background noise levels (L90) recorded in Table 1 of this report the criteria noise
levels from the Environmental Protection (Noise) Policy in relation to Background Creep for are:
Time Period Noise Criteria for Noise Criteria For Time
Continuous Noise Varying Sources SPL
Sources dB(A) Leq
SPL dB(A) L90
Day 7 am – 6pm 48 53 {(L90)+ 5 dB}
Evening 6 pm – 10pm 43 48 {(L90)+ 5 dB}
Night 10 pm – 7am 37 42 {(L90)+ 5 dB}
Table 2: Noise Criteria Levels
The noise limit criteria presented in the above table relate to measured corrected limits, where corrections
must be applied to allow for tonal or impulsive characteristics as per Australian Standard AS 1055.
5.3 On-Site Activity Noise- Pool Area – Source Noise Levels
Measured source noise levels and their duration of activities typical of the car park and recreation activities
have been included in the table below. These levels have been taken from previous reports prepared by
Decibell Consulting are presented in relation to the various noise parameters.
Noise Source Corrected Corrected Corrected Duration of
Source Level Source Level Source Level Event
@ 1m @ 1m @ 1m Min:Sec
LAeq LA10 LA1
Residents talking in Pool l Area 60 70 74 1:00
Swimmer doing laps 75 77 79 15:00
Child playing boisterously 75 78 81 15:00
in pool area
Table 3: Measured Source Noise levels of On-site activities
Decibell Report No. 2102318 Page 10
Page 11
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
5.4 Background Creep Assessment
The source noise levels presented in Section 5.3 have been used to model the noise impacts at the
surrounding nearest noise sensitive premises. The results of this modelling are presented in the table below.
Details of the calculations used to determine these levels are included in the appendix to this report.
Noise Source House at 35 Regatta Court House at 33 Regatta Court
LAeq LAeq
Residents talking in Communal Area 36 40
Swimmer doing laps 53 54
Child playing boisterously 53 54
in pool area
Table 4: Predicted noise impacts from Pool Area
on the dwellings surrounding the site
Decibell Report No. 2102318 Page 11
Page 12
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
6.0 RECOMMENDED ACOUSTIC TREATMENTS
6.1 Noise impacts from Surrounding Noise Sources on the Proposed Development
Existing noise levels were measured at the site. During the measurements the commercial businesses were
in operation and the scoffing businesses accessed their site to retrieve materials. These noise measured
noise levels were then used to determine a series of acoustic treatments in order to achieve the internal
Acoustic Quality Objectives from the Environmental Protection (Noise) Policy 2008.
In order to achieve the required internal Acoustic Quality Objectives from the Environmental Protection
(Noise) Policy 2008 if proposed that a series of acoustic treatment be applied to the proposed development.
Details of the required acoustic rating of these elements are included in that table below and over the page.
Further details of the calculations used to determine these ratings are contained in the appendix of this
report.
Building Recommended
Apartment Room Elements Minimum Acoustic
Treatment Rw
Building 01
APT 04 & 09
Living Room
Sliding Doors Rw 26
Bedrooms 1 & 2
Windows Rw 23
APT 05-08
Living Room
Sliding Doors Rw 26
Bedrooms 1 & 2
Windows Rw 23
APT 18-22
Living Room
Sliding Doors Rw 27
Bedrooms 1 & 2
Windows Rw 25
APT 23
Living Room
Sliding Doors Rw 27
Bedrooms 1, 2 & 3
Windows Rw 25
Table 5 : Recommended Acoustic Ratings Rw Of Building Elements
In Building 01
Decibell Report No. 2102318 Page 12
Page 13
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Building Recommended
Apartment Room Elements Minimum Acoustic
Treatment Rw
Building 02
APT 10 & 14
Living Room
Sliding Doors Rw 26
Bedroom 1
Windows Rw 23
Bedroom 2
Windows Rw 23
APT 11-13
Living Room
Sliding Doors Rw 26
Bedroom 1
Windows Rw 23
Bedroom 2
Windows Rw 23
APT 24 & 28
Living Room
Sliding Doors Rw 27
Bedroom 1
Windows Rw 25
Bedroom 2
Windows Rw 25
Bedroom 3
Windows Rw 25
APT 25 & 27
Living Room
Sliding Doors Rw 27
Bedroom 1
Windows Rw 25
Bedroom 2
Windows Rw 25
Bedroom 3
Windows Rw 25
APT 26
Living Room
Sliding Doors Rw 27
Bedroom 1
Windows Rw 25
Bedroom 2
Windows Rw 25
Table 6: Recommended Acoustic Ratings Rw Of Building Elements
In Building 02
Decibell Report No. 2010137 Page 13
Page 14
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
6.2 Noise impacts from Pool Area
In section 5.4 of this noise impacts from the Pool Area were modelled and assessed against the Background
Creep Criteria from the Environmental Protection (Noise) Policy 2008. This assessment determined that
some noise impacts from this area would exceed this criteria.
In order to mitigate the noise impacts from the pool area on these neighbouring properties it is recommended
that a 1.8 m high acoustic fence be constructed along boundary of the site adjacent to this area. The location
of this fence is show over the page. The proposed acoustic barrier would be solid, gap free and achieve a
surface density of at least 11 kg/m2. The barrier could be constructed of double lapped timber, fibre cement
or masonry. The barrier would be constructed adjacent to retaining wall and would have a gap to allow
drainage. The arrangement of the barrier and retaining wall are also shown on the diagram over the page.
Modelling of the mitigation provided by the proposed acoustic fence has been conducted in the appendix to
this report. Details of this modelling are included in the appendix to this report. The results of the modelling
are presented in the table below and show all noise impacts from the pool area will now comply with the
Background Creep Assessment Criteria from the Environmental Protection (Noise) Policy 2008.
Noise Source House at 35 Regatta Court House at 33 Regatta Court
LAeq LAeq
Residents talking in Communal Area 31 32
Swimmer doing laps 43 45
Child playing boisterously 43 45
in pool area
Table 7: Predicted noise impacts from Pool Area
on the dwellings surrounding the site with 1.8 m High Acoustic Fence
In addition to the proposed 1.8 m acoustic barriers to further limit the noise impacts from the pool area
overnight is also proposed to limit the hours of the Pool to between 7.00 am to 9.00 pm seven days a week.
Decibell Report No. 2102318 Page 14
Page 15
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Figure 3: Details of Proposed Acoustic Fence
Decibell Report No. 2010137 Page 15
Page 16
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
7.0 DISCUSSION & CONCLUSIONS
The proposed development is located adjacent to a commercial building to the north and a storage yard for a
scaffold business to the east. Noise impacts from these businesses on the proposed development have been
considered in this report. In line with SC6.2.4 Appendix 1 - Requirements for technical assessments and
reports of the Noose Shire Plan 2020 reference was made to both the requirements of the Acoustic quality
Objectives for the Environmental Protection (Noise) Policy 2008 (EPP Noise) and Australian Standard AS
2107 Acoustics – Recommended design sound levels and reverberation times for building interiors. In order
to satisfy both these standards a series of acoustic treatments have been recommended to be applied to the
dwellings in order to achieve the internal noise levels from both of these standards. Details of these acoustic
treatments have been details in Section 6.1 of this report.
Noise impacts from the proposed pool area in the south east corner of the site on neighbouring properties
was also consider in Section 5.4 of this report. This assessment determined that noise impacts from the Pool
Area would exceed the Background Creep Criteria from the Environmental Protection (Noise) Policy 2008. In
order to mitigate the noise impacts from the pool area on these neighbouring properties it has been
recommended that a 1.8 m high acoustic fence be constructed along boundary of the site adjacent to this
area. The location of this fence is show Section 6.2 of this report. The proposed acoustic barrier would be
solid, gap free and achieve a surface density of at least 11 kg/m2. The barrier could be constructed of
double lapped timber, fibre cement or masonry.
The development is also not located within a Transport Noise Corridor and as such the impacts of transport
noise on the development have not been considered.
Subject to our calculations, the recommended acoustic building treatments, the proposed acoustic fence
adjacent to the pool area and conditions relating to hours of operation of the pool area, we believe that the
development will meet all requirements of Dual Occupancy and Multiple Dwelling Code of the Noose Shire
Plan 2020 and should be approved.
Report Compiled By:
John Cristaudo
Acoustic Consultant
Decibell Consulting
Decibell Report No. 2102318 Page 16
Page 17
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
APPENDIX
[OCR of page images]
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
APPENDIX
Page 18
Proposed Development Site Sketch No. 1 Location of Development [OCR of page images] Proposed Development Site Sketch No. 1 Location of Development 40 consutting Peace: poe ? . ‘ity Retreat Noosa < Headiand peo A }101 Eumundi Noosa Rd, Foote coy ag oe a verte Dr Vv an 7 of Boiling Pot Brewing @ e Z %, De. Park Project Ave F1 car & dog wash : \ ke Sty, \ i KFC Noosaville Q) oP sei Noosaville a ‘ pt Donovan or Bakery & Café Bunnings Noosaville) (al a aa ‘ AS \ SAVILLE 2 , ee \) Land & Sea - Noosa j 1, ) Brewing Company yo 3 - > AS \ g g ow Bushlands _ 4 i Gregson J *e.” E ey << Commerce ct > Se seragyal OCF (Bean Comping GK - Map data @2021 Australia Terms Send feedback _ 200 mt_____s
Page 19
Page 19
[OCR of page images]
PROJECT SUMMARY
101 AND 105 EUMUNDI ROAD, NOOSAVILLE
LOT 1 ON RP849431 AND LOT 1 ON RP230931
NOOSA SHIRE COUNCIL
SITE AREA: 5488m*
PROPOSED DEVELOPMENT : 28 x 2 BED APARTMENTS + 6 x 3 BED APARTMENTS
= TOTAL: 34 x DWELLINGS
SITE COVER CALCULATIONS
PERMITTED TOTAL SITE COVER. = 45% oF 26897
PROPOSED TOTAL SITE COVER Ted + 6S2e? + 678? +397? 42% oF 2289me
LANDSCAPE AREA CALCULATION
TOTAL LANOSCAPE AREA REQUIRED =30% or 1647?
‘TOTAL LANOSCAPE AREA PROVIDED 024% oF 2825m"
‘SOFT LANDSCAPE AS % OF TOTAL PROVIDED 1% oF 1726
HARD LANDSCAPE AS % OF TOTAL PROVIDED = 26% oF 599m"
PLOT RATIO _ DWELLING CALCULATIONS
TOTAL PERMITTED PLOT RATIO=0'5to 1.0 {SMALL DWELLINGS} 50% or 2657
TOTAL PROPOSED PLOT RATIO 50% or 2742
TYPE} = § x85 425m
TYPE 02 = 1x 1050 - 105m?
TYPE 03 = 16 75 080m?
TYPE 06 = 9x 78m? 702m?
TYPE 05 = 5x 92m" 60m
CAR PARKING AND SERVICE VEHICLE PROVISIONS
[APARTMENT CARPARKING REQUIRED mx)
= 6x2
[APARTMENT CARPARKING PROVIDED
VISITOR CARPARKING REQUIRED = 1025,
VISITOR CARPARKING PROVIDED
SERVICE VEHICLES PROVIDED: = 1xMRV yey
21 REFUSE
NOTES:
ALL CARPARKING IN ACCORDANCE WITH AS2690.1
MINIMUM TYPICAL DIMENSIONS, CARPARK AISLE: 58m WIDE
SINGLE CAR. 54m x2.5m
ALTUM CONSTRUCTIONS
PROPOSED MULTIRESIDENTIAL DEVELOPMENT,
EUMUNDI NOOSA ROAD, NOOSAVILLE
PROJECT SUMMARY
ee BUICK BURNEJ/CK(SON
ARCHITECTURE | LANOSCAPE | INTERIOR | PROJECT MANAGEMENT
fesue: 06 date: 05-02-21
7186-DA01
Page 20
Page 20
[OCR of page images]
14
}
1h
L i
J :
-—— r\ Ss
\ J \e-
> /
{
/
I
(7 \ 7
\ /
o/s
a
(J |
Fy il neruse
7 yl
|
i i! +
an
it |
1 |!
! Ig Kio
i a
oul =<
iin = BLDG 04-
bar od APT Bo
tht 02 a
\
SITE PLAN LEVEL 1 GROUND
1200
PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ALTUM CONSTRUCTIONS iovigreinhiamaas & BLICKBURNEJCSON
EUMUNDI NOOSA ROAD, NOOSAVILLE SITE PLAN LEVEL 1 GROUND 7186-DA02
E | LANDSCAPE | INTERIOR | PROJECT MANAGEMEN!
Page 21
Page 21 [OCR of page images] 01 SITE PLAN LEVEL 2 UPPER 1200 PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ALTUM CONSTRUCTIONS oot a & EUMUNDI NOOSA ROAD, NOOSAVILLE SITE PLAN LEVEL 2 UPPER 7186-DA03
Page 22
Page 22 [OCR of page images] [oning| 01 FLOOR PLAN LEVEL 1 GROUND - BUILDING 01 7100 FLOOR PLAN LVL1GROUND- "sea EUMUNDI NOOSA ROAD, NOOSAVILLE BUILDING 01 7186-DAO4 ee PROPOSED MULTIRESIDENTIAL DEVELOPMENT, = Auruconsrrucnions, samen BLICKBURNEJ/CKSON
Page 23
Page 23 [OCR of page images] 01 FLOOR PLAN LEVEL 2 UPPER - BUILDING 01 PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ALTUM CONSTRUCTIONS a EUMUNDI NOOSA ROAD, NOOSAVILLE FLOOR PLAN LVL 2UPPER= rouge ee ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT
Page 24
Page 24 [OCR of page images] 01 FLOOR PLAN LEVEL 1 GROUND - BUILDING 02 7100 ate : 05-02-21 EUMUNDI NOOSA ROAD, NOOSAVILLE BUILDING DY ae ans PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ——Auycovsrrucnoys sarong 5°. BUICKBURNEJ/CKSON rage er
Page 25
Page 25 [OCR of page images] ? 5 } 01 FLOOR PLAN LEVEL 2 UPPER - BUILDING 02 FLOOR PLAN LVL 2 UPPER mee aes <I EUMUNDI NOOSA ROAD, NOOSAVILLE BUILDING 02 , 7186-DA07 ° PROPOSED MULTIRESIDENTIAL DEVELOPMENT, — ALTUMCONSTRUCTIONS = peretorwemarom == BU IAW BIRNEJICKSON
Page 26
Page 26 [OCR of page images] GARAGE o1 FLOOR PLAN LEVEL 1 GROUND - BUILDING 03 1100 02 FLOOR PLAN LEVEL 2 UPPER - BUILDING 03 700 PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ——ALTUM CONSTRUCTIONS sasameNer—. "BY IAW BIBNE JICKSON FLOOR PLANLVL1GROUND& “= sateen EUM UNDI NOOSA ROAD, NOOSAVILLE LVL 2 UPPER - BUILDING 03 7186-DA08 - eth NLL
Page 27
Page 27
[OCR of page images]
a---f--, | BIE} ef eee
a
01 FLOOR PLAN LEVEL 1 GROUND - BUILDING 04
700
FLOOR PLAN LVL1GROUND- #21
EUMUNDI NOOSA ROAD, NOOSAVILLE BUILDING 04 7186-DA09
PROPOSED MULTIRESIDENTIAL DEVELOPMENT, = ATuwconstrucrins | sssannems =. BUICKBURNEJ/CKSON
sagen
Page 28
Page 28 [OCR of page images] 01 FLOOR PLAN LEVEL 2 UPPER - BUILDING 04 FLOOR PLAN LVL 2 UPPER EUMUNDI NOOSA ROAD, NOOSAVILLE BUILDING te ge-pato 1ays cu PROPOSED MULTIRESIDENTIAL DEVELOPMENT, —ALTUMCONSTRUCTIONS ——sascrvereermoms = BY IEW BUBNIEJICKSON
Page 29
Page 29
[OCR of page images]
01 NORTH ELEVATION (SITE)
7200
02 EAST ELEVATION (SITE)
7200
ioe
EUMUNO NOOSA ROAD
03 SOUTH ELEVATION [SITE]
1200
04 WEST ELEVATION [SITE]
¥200
REFER TO DRAWING DA20 FOR EXTERNAL FINISHES SCHEDULE
PROPOSED MULTIRESIDENTIAL DEVELOPMENT,
EUMUNDI NOOSA ROAD, NOOSAVILLE
DEVELOPMENT APPROVAL
scale: 1:200@A1 1-400 @A3
jesve: 0 date 05-02-21
7186-DA11
ALTUM CONSTRUCTIONS
BLICKBUINEJ/CKSON
ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT
ELEVATIONS - SITE
Page 30
Page 30
[OCR of page images]
~~ = 4+ --- "gna
1 NORTH ELEVATION (1)
03
REFER TO DRAWING DA20 FOR EXTERNAL FINISHES SCHEDULE
PROPOSED MULTIRESIDENTIAL DEVELOPMENT, — ALTUM CONSTRUCTIONS Bxvsarvensrrom BY IAW BENE /CKSON
ue: 0 date: 05-02-21
EUMUNDI NOOSA ROAD, NOOSAVILLE ELEVATIONS - BUILDING 01 7186-DA12
1 ays vu
ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT
Page 31
Page 31
[OCR of page images]
ripe
Was i) Ut a —_—_«
IOI
FBrarora orouN0 UNE SQ
>
>
QS
OS
S
ORG
gS
Q
Q
S
>
KEY SKS
5 Ky eS So
RK SES S$
S$ SS
S '>KMSOIES S
X SY SIKYS
Li oe
S SLA S
o NORTH ELEVATION (2)
@
@
©
v
gL
m §
ATURAL ORUN Ue
—
S
SK
SKY
03 SOUTH ELEVATION (2)
PROPOSED MULTIRESIDENTIAL DEVELOPMENT,
EUMUNDI NOOSA ROAD, NOOSAVILLE
é ey ve i
SELF ‘Sy
SRY S SII
wy S Ss Ss
SY
=
GOI
S S S
SY
S
SYLSYE
YSZ
YOY
SYAYSTS WAS SS LA
02 EAST ELEVATION (2
Toms
nies!
YE WW WHS
YSIS
SOARRA
SKY
SAS
YOLSE
eS
SK
CS
WSK
?YOFD
Sy
SYS
04 WEST ELEVATION (2)
i
Sy
REFER TO DRAWING DA20 FOR EXTERNAL FINISHES SCHEDULE
sean BUICK BURNEJ/CKSON
iesve: 06 date = 05-02-21
ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT
ELEVATIONS - BUILDING 02 7186-DA13
Page 31
ALTUM CONSTRUCTIONS
Page 32
Page 32 [OCR of page images] EAST ELEVATION (3) Ti NORTH ELEVATION (3) 710 WEST ELEVATION (3} 190 ‘SOUTH ELEVATION (3} 0 REFER TO DRAWING DA20 FOR EXTERNAL FINISHES SCHEDULE PROPOSED MULTIRESIDENTIAL DEVELOPMENT, ——ALTUMCONSTRUCTIONS ——2eLonENTArO™N BAW BUN JC SON EUMUNDI NOOSA ROAD, NOOSAVILLE ELEVATIONS -BUILOINGO3 7166-081 eS 1 ays ve
Page 33
Page 33 [OCR of page images] Bt NN RETAINING WALL SECTION 13100 ‘SecmON CUT UNE SS = Sout NONE ‘seTanck 2000 i TT i i EAST RETAINING (SITE) 1100 REFER TO DRAWING DA20 FOR EXTERNAL FINISHES SCHEDULE PROPOSED MULTIRESIDENTIAL DEVELOPMENT, — ALTUMCONSTRUCTIONS = esorvemsrroms BY TA BUBAIE JCKSON EUMUNDI NOOSA ROAD, NOOSAVILLE aaa ree fade ELEVATIONS - RETAINING WALL =?) #77! ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT Hage ve
Page 34
Ambient Noise Levels
Page 34
[OCR of page images]
Ambient Noise Levels
Page 34
Page 35
Sound Pressure Level dB(A)
10
30
40
50
60
80
90
20
70
0
11:30:00
16:15:00
21:00:00
1:45:00
6:30:00
11:15:00
16:00:00
20:45:00
1:30:00
6:15:00
11:00:00
15:45:00
20:30:00
1:15:00
6:00:00
10:45:00
15:30:00
20:15:00
1:00:00
Time 5:45:00
Page 35
10:30:00
15:15:00
20:00:00
0:45:00
Exising Noise Levels
5:30:00
10:15:00
15:00:00
19:45:00
0:30:00
5:15:00
10:00:00
14:45:00
19:30:00
0:15:00
5:00:00
9:45:00
L1
L90
L10
Leq
[OCR of page images]
Noise Levels
ising
Ex
—L10
Leq
L90
90
(v)ap [aAa7 aunssaig punos
10
00:St:6
00:00:S
00:ST:0
00:0€:6T
00:St:7T
00:00:0T
00:ST:S
00:0€:0
00:St:6T
00:00:ST
00:ST:OT
00:0€:S
00°:St:0
00:00:02
00:ST:ST
00:0€:0T
00:St:S
00:00:T
00:ST:0Z
00:0€:ST
00:St:0T
00:00:9
00:ST:T
00:0€:02
00:St:ST
00:00: TT
00:ST:9
00:0€:T
00:S7:07
00:00: 9T
00:ST:TT
00:0€:9
00:St:T
00:00:TZ
00:ST:9T
00:0€: TT
Time
Page 35
Page 36
Proposed Apartment Building
16 Mylne St, Toowoomba
Acoustic
Report
Calculations of Acoustic Treatments
Page 37
Building Element Floor
Space Component Impact Criteria TNR Area Area Height RT60 C TNA Rw
dB(A) dB(A) dB(A) (m2) (m2) (m) (s)
APT 04 & 09
Entry
Hinged Door 53 35 18.0 2 8 2.4 0.5 2 15 21
Wall 53 35 18.0 2 8 2.4 0.5 2 16 22
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 2 20 26
Wall 53 35 18.0 3 14 2.4 0.5 2 15 21
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 16 10 2.4 0.5 2 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 12 10 2.4 0.5 2 23 29
APT 05-08
Entry
Hinged Door 53 35 18.0 2 8 2.4 0.5 2 15 21
Wall 53 35 18.0 2 8 2.4 0.5 2 16 22
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 2 20 26
Wall 53 35 18.0 3 14 2.4 0.5 2 15 21
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 9 10 2.4 0.5 2 22 28
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 4 10 2.4 0.5 2 18 24
APT 10 & 14
Entry
Hinged Door 53 35 18.0 2 8 2.4 0.5 2 15 21
Wall 53 35 18.0 2 8 2.4 0.5 2 16 22
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 2 20 26
Wall 53 35 18.0 3 14 2.4 0.5 2 15 21
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 16 10 2.4 0.5 2 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 12 10 2.4 0.5 2 23 29
APT 11-13
Entry
Hinged Door 53 35 18.0 2 8 2.4 0.5 2 15 21
Wall 53 35 18.0 2 8 2.4 0.5 2 16 22
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 2 20 26
Wall 53 35 18.0 3 14 2.4 0.5 2 15 21
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 9 10 2.4 0.5 2 22 28
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 2 17 23
Wall 53 35 18.0 4 10 2.4 0.5 2 18 24
Page 37
[OCR of page images]
APT 04 & 09
Living Room 1
Bedroom 1
Bedroom 2
APT 05-08
Living Room 1
Bedroom 1
Bedroom 2
APT 10 & 14
Living Room 1
Bedroom 1
Bedroom 2
APT 11-13
Living Room 1
Bedroom 1
Bedroom 2
Hin Door
Wall
Sliding Door
Wall
Windows
Wall
Windows
Wall
Hin Door
Wall
Sliding Door
Wall
Windows
Wall
Windows
Wall
Hin Door
Wall
Sliding Door
Wall
Windows
Wall
Windows
Wall
Hin Door
Wall
Sliding Door
Wall
Windows
Wall
Windows
Wall
Page 37
Page 38
Building Element Floor
Space Component Impact Criteria TNR Area Area Height RT60 C TNA Rw
dB(A) dB(A) dB(A) (m2) (m2) (m) (s)
APT 18
Living Room
1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 9 10 2.4 0.5 3 23 29
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 4 10 2.4 0.5 3 20 26
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 19-22
Living Room
1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 9 10 2.4 0.5 3 23 29
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 4 10 2.4 0.5 3 20 26
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 23
Living Room
1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 16 10 2.4 0.5 3 26 32
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 3
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Page 38
[OCR of page images]
APT 18
Living Room
1
Bedroom 1
Bedroom 2
APT 19-22
Living Room
1
Bedroom 1
Bedroom 2
APT 23
Living Room
1
Bedroom 1
Bedroom 2
Bedroom 3
Siding Door
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Siding Door
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Siding Door
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Windows
Wall
Roof/Ceilin
Page 38
Page 39
Building Element Floor
Space Component Impact Criteria TNR Area Area Height RT60 C TNA Rw
dB(A) dB(A) dB(A) (m2) (m2) (m) (s)
APT 24 & 28
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 16 10 2.4 0.5 3 26 32
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 3
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 25 & 27
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 6 10 2.4 0.5 3 22 28
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 7 10 2.4 0.5 3 22 28
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 3
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 26
Living Room 1
Slding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 0.5 3 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 9 10 2.4 0.5 3 23 29
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 3 19 25
Wall 53 35 18.0 4 10 2.4 0.5 3 20 26
Roof/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Page 39
[OCR of page images]
Building bates Floor
Component Impact Criteria TNR NC) NC) Height RT60
CIEXC 10.) LEC) (GW) (GW) (m) (6)
APT 24 & 28
Living Room 1
Sliding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 05 | 3 | 17 23
Rooft/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 | 3 | 19 25
Wall 53 35 18.0 16 10 2.4 0.5 | 3 | 26 32
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 0.5 | 3 | 19 25
Wall 53 35 18.0 12 10 2.4 0.5 3 25 31
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 | 3 | 24 30
Bedroom 3
Windows 53 35 18.0 3 10 2.4 0.5 | 3 | 19 25
Wall 53 35 18.0 12 10 2.4 0.5 | 3 | 25 31
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 25 & 27
Living Room 1
Sliding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 05 | 3 | 17 23
Rooft/Ceiling 53 35 18.0 14 14 2.4 0.5 3 24 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 | 3 | 19 25
Wall 53 35 18.0 6 10 2.4 0.5 | 3 | 22 28
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 | 3 | 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 05 | 3 | 19 25
Wall 53 35 18.0 7 10 2.4 05 | 3} 22 28
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 | 3 | 24 30
Bedroom 3
Windows 53 35 18.0 3 10 2.4 0.5 | 3] 19 25
Wall 53 35 18.0 12 10 2.4 0.5 | 3 | 25 31
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 3 24 30
APT 26
Living Room 1
Sliding Door 53 35 18.0 8 14 2.4 0.5 3 21 27
Wall 53 35 18.0 3 14 2.4 05 | 3} 17 23
Roof/Ceiling 53 35 18.0 14 14 2.4 05 |3| 24 | 30
Bedroom 1
Windows 53 35 18.0 3 10 2.4 0.5 | 3 | 19 25
Wall 53 35 18.0 9 10 2.4 0.5 | 3 | 23 29
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 | 3 | 24 30
Bedroom 2
Windows 53 35 18.0 3 10 2.4 05 | 3 | 19 25
Wall 53 35 18.0 4 10 2.4 0.5 | 3 | 20 26
Rooft/Ceiling 53 35 18.0 10 10 2.4 0.5 | 3 | 24 30
Page 39
Page 40
POINT SOURCE CALCULATIONS
Page 40
[OCR of page images]
POINT SOURCE CALCULATIONS
Page 40
Page 41
Noise impacts on Dwelling at 35 Regatta Court
Point Source Calculations Point Source Calculations
Residents Talking in Pool area for a Swimmer Doing Laps for a single event 75 dB(A) at 1m
single event 60 dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Duration of a Single Event 1:00 Min:Sec
Number of Event s 15 minute period 1
Number of Event s 15 minute period 7
Total duration of combined Events 15:00 Min:Sec
Total duration of combined Events 7:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Source level for assessment time period 56.7 dB(A)
Distance to Receiver 13 m
Distance to Receiver 11 m
Distance Reduction -22.3 dB(A)
Distance Reduction -20.8 dB(A)
Level at Façade 53 dB(A)
Level at Façade 36 dB(A)
Point Source Calculations
Child Playing Boisterously for a single
event 75dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Number of Event s 15 minute period 1
Total duration of combined Events 15:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Distance to Receiver 13 m
Distance Reduction -22.3 dB(A)
Level at Façade 53 dB(A)
Noise impacts on Dwelling at 35 Regatta Court
Point Source Calculations Point Source Calculations
Residents Talking in Pool area for a
Swimmer Doing Laps for a single event 75 dB(A) at 1m
single event 60 dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Duration of a Single Event 1:00 Min:Sec
Number of Event s 15 minute period 7 Number of Event s 15 minute period 1
Total duration of combined Events 7:00 Min:Sec Total duration of combined Events 15:00 Min:Sec
Source level for assessment time period 56.7 dB(A) Source level for assessment time period 75.0 dB(A)
Distance to Receiver 7m Distance to Receiver 11 m
Distance Reduction -20.8 dB(A)
Distance Reduction -16.9 dB(A)
Level at Façade 54 dB(A)
Level at Façade 40 dB(A)
Point Source Calculations
Child Playing Boisterously for a single
event 75dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Number of Event s 15 minute period 1
Total duration of combined Events 15:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Distance to Receiver 11 m
Distance Reduction -20.8 dB(A)
Level at Façade 54 dB(A)
Page 41
Page 42
Noise impacts on Dwelling at 35 Regatta Court with 1.8 m high Acosutic Fence
Point Source Calculations Point Source Calculations
Residents Talking in Pool area for a Swimmer Doing Laps for a single event 75 dB(A) at 1m
single event 60 dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Duration of a Single Event 1:00 Min:Sec
Number of Event s 15 minute period 1
Number of Event s 15 minute period 7
Total duration of combined Events 15:00 Min:Sec
Total duration of combined Events 7:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Source level for assessment time period 56.7 dB(A)
Distance to Receiver 13 m
Distance to Receiver 11 m
Distance Reduction -22.3 dB(A)
Distance Reduction -20.8 dB(A)
Barrier Reduction -9.7 dB(A)
Barrier Reduction -6.9 dB(A)
Level at Façade 43 dB(A)
Level at Façade 31 dB(A)
Point Source Calculations
Child Playing Boisterously for a single
event 75dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Number of Event s 15 minute period 1
Total duration of combined Events 15:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Distance to Receiver 13 m
Distance Reduction -22.3 dB(A)
Barrier Reduction -9.7 dB(A)
Level at Façade 43 dB(A)
Noise impacts on Dwelling at 35 Regatta Court with 1.8 m high Acosutic Fence
Point Source Calculations Point Source Calculations
Residents Talking in Pool area for a Swimmer Doing Laps for a single event 75 dB(A) at 1m
single event 60 dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Duration of a Single Event 1:00 Min:Sec
Number of Event s 15 minute period 1
Number of Event s 15 minute period 7
Total duration of combined Events 15:00 Min:Sec
Total duration of combined Events 7:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Source level for assessment time period 56.7 dB(A)
Distance to Receiver 11 m
Distance to Receiver 7m
Distance Reduction -20.8 dB(A)
Distance Reduction -16.9 dB(A)
Barrier Reduction -9.4 dB(A)
Barrier Reduction -8.3 dB(A)
Level at Façade 45 dB(A)
Level at Façade 32 dB(A)
Point Source Calculations
Child Playing Boisterously for a single
event 75dB(A) at 1m
Duration of a Single Event 15:00 Min:Sec
Number of Event s 15 minute period 1
Total duration of combined Events 15:00 Min:Sec
Source level for assessment time period 75.0 dB(A)
Distance to Receiver 11 m
Distance Reduction -20.8 dB(A)
Barrier Reduction -9.4 dB(A)
Level at Façade 45 dB(A)
Page 42