Rfi - Attachment E - Acoustic Report

of 42

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                                         Proposed Multiple Dwellings
                                                                                                                               101-105 Eumundi Noosa Rd, Noosaville
                                                                                                                                                   Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------




5.2 Background Creep Criteria
Based on the measured background noise levels (L90) recorded in Table 1 of this report the criteria noise
levels from the Environmental Protection (Noise) Policy in relation to Background Creep for are:


                          Time Period                                       Noise Criteria for                      Noise Criteria For Time
                                                                            Continuous Noise                         Varying Sources SPL
                                                                                Sources                                    dB(A) Leq
                                                                             SPL dB(A) L90
                          Day 7 am – 6pm                                           48                                     53 {(L90)+ 5 dB}
                          Evening 6 pm – 10pm                                           43                                48 {(L90)+ 5 dB}
                          Night 10 pm – 7am                                             37                                42 {(L90)+ 5 dB}


                                                                  Table 2: Noise Criteria Levels

The noise limit criteria presented in the above table relate to measured corrected limits, where corrections
must be applied to allow for tonal or impulsive characteristics as per Australian Standard AS 1055.




5.3 On-Site Activity Noise- Pool Area – Source Noise Levels

Measured source noise levels and their duration of activities typical of the car park and recreation activities
have been included in the table below. These levels have been taken from previous reports prepared by
Decibell Consulting are presented in relation to the various noise parameters.


          Noise Source                                           Corrected                   Corrected                   Corrected                    Duration of
                                                                Source Level                Source Level                Source Level                    Event
                                                                   @ 1m                        @ 1m                        @ 1m                        Min:Sec
                                                                       LAeq                        LA10                        LA1
          Residents talking in Pool l Area                              60                         70                          74                          1:00
          Swimmer doing laps                                            75                         77                          79                         15:00
          Child playing boisterously                                    75                         78                          81                         15:00
          in pool area

                                         Table 3: Measured Source Noise levels of On-site activities




Decibell Report No. 2102318                                                                                                                                      Page 10
Log in to download the original file

RFI - ATTACHMENT E - ACOUSTIC REPORT.pdf · 6.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.