Rfi - Attachment E - Acoustic Report
Proposed Multiple Dwellings
101-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
3.0 MEASUREMENT PROCEDURE
3.1 Logger Noise Measurement
A noise logger was located on site adjacent scaffolding business at the rear of the site and commercial
business north of the site. The location of the logger is indicated on the aerial photograph included below.
Logger Measurement
Location
Figure 1: Measurement Location
The logger was set to record noise statistics in 15 minute blocks continually over an 168 hour period from
Thursday the 7/01/21 to Thursday 14/01/21. Ambient noise level measurements were conducted generally
in accordance with Australian Standard AS1055 2018 “Acoustics – Description & Measurement of
Environmental Noise”.
The operation of the sound level measuring equipment was field calibrated before and after the
measurement session and was found to be within 0.1 dB of the reference signal. All instrumentation used in
this assessment hold current calibration certificate from a certified NATA calibration laboratory.
Weather conditions during the survey period included rain periods over the weekend of Saturday the 9th and
th
Sunday the 10 of January; these periods have been excluded from the measurement data. During the
logging period temperatures ranged from 19 ˚ C to 29˚ C.
Decibell Report No. 2102318 Page 4