Council archive · source document
Appendix E - Architectural Plans · MCU25/0053
Plans and drawings: the text below has words only, no drawings.
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
6 CONSULTANT ISSUE 02.05.25
5 CONSULTANT ISSUE 30.04.25
4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
2 CONSULTANT COORDINATION 16.01.25
1 STRUCTURAL ENG INFORMATION 08.01.25
A B C A B C
REV DESCRIPTION DATE
REVISION SCHEDULE
LEGEND
CODE DESCRIPTION
AFG-01 ALUMINIUM FRAMED GLAZING - TYPE 1
AFG-SD1 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 4-PANEL XXXO
AFG-SD2 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 3-PANEL XXO
2005 11210 4400 2500
AFG-SD3 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 2-PANEL XO
SETBACK SETBACK
BAL-01 BALUSTRADE TYPE 1
BAL-02 BALUSTRADE TYPE 2
8M HEIGHT CNC-PF CONCRETE - PAINT FINISH
COL-A CONCRETE COLUMN - PAINT FINISH
RND RENDER - PAINT FINISH
ROOF SCN-01 ALUMINIUM SCREEN - POWDERCOAT FINISH
RL 9.800
SGG SLIDING GLASS GATE
SMG SLIDING METAL GATE
SST STACKED STONE VENEER
SCN-01
3450
01_FIRST FLOOR
RL 6.350
AFG-01 1500
SETBACK
1800 FRONT BOUNDARY
3650
FENCE AND GATE
RND
SGG
00_GROUND FLOOR SST SMG
RL 2.700 DFL
RL 2.400
NATURAL GROUND LINE
NORTH ELEVATION FRONT BOUNDARY ELEVATION
1 1 : 100
3 1 : 100
GENERAL NOTES:
1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
SYSTEMS, LININGS & FINISHES.
2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
UPPERMOST FFL NOTED ONLY.
4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
DEFLECTION AND STRUCTURAL MOVEMENT.
5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
C B A C B A REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
REQUIREMENTS.
7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
WITH AS2419 AND AS2441.
8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
CONSTRUCTION.
9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
INFORMATION.
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
2500 4400 11210 2005 STRUCTURAL ENGINEERS DETAILS
SETBACK SETBACK
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
8M HEIGHT 13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
CNC-PF 14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
ROOF FINISH.
RL 9.800 15. DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
AFG-SD3 AFG-01 AFG-SD1 REQUIREMENTS.
16. ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
VERIFY PRIOR TO CONSTRUCTION.
3450
SCN-01
BAL-01
CNC-PF
01_FIRST FLOOR SST
RL 6.350
AFG-SD1 AFG-SD2
COL-A COL-A
3650
bureau^proberts PTY LTD
ABN 53 073 087 993 ACN 073 087 993
LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au
BAL-02 CLIENT:
00_GROUND FLOOR
RL 2.700 DFL DFL SEYMOUR GROUP
RL 2.400 RL 2.400 PROJECT:
BAL-02 BAL-02
SST
NOOSA RESIDENCE
NATURAL GROUND LINE ADDRESS:
7 NOOSA PARADE
DRAWN BY: NORTH:
TH
CHECK BY:
JC
PROJECT
SOUTH ELEVATION REAR BOUNDARY ELEVATION ARCHITECT JC
2 1 : 100
4 1 : 100
DESIGN
ARCHITECT AB
SCALE:
5 1 : 100 [A1]
DRAWING TITLE:
NORTH & SOUTH ELEVATIONS
CAD FILE REF: DATE:
C: \_Revit Local\24048_7 Noosa Parade_B.A_JasonC9U8GC. rvt
02.05.25
PROJECT NO: PHASE: DRAWING NUMBER: REVISION:
24048 B.A. AR 30.01 6
2/05/2025 4:56:55 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.