08/0170 - Response to Information Request [As Published] · 132008.170

of 5

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

ALTIUM

CONSTRUCTIONS

28" March 2008

Land Use Section
Noosa Shire Council
PO Box 141 .
TEWANTIN QLD 4565

Attention: Murray Bell

 

Dear Sir

RE: Application for a Development Permit for 08/0170 Multiple Housing Type
2 - Duplex situated at 8 Egret Street PEREGIAN BEACH described as
LOT: 293 P: 93112

| refer to the above development application and Information Request dated 10"
March 2008 and wish to respond to the aspects raised as follows. Please note that
council's Information Request Items are shown in italics and the response is provided
immediately below.

1. Please provide a stormwater drainage plan indicating in particular rainwater
storage tanks and the location and fall of drainage pipes leading to Egret Street.

Please find enclosed a stormwater drainage plan prepared by Construction
Hydraulic which indicates rainwater storage tanks and the location and fall of
drainage pipes leading to Egret Street.

2. Please provide an alternative guest parking design that allows vehicles to reverse
out ~ turn around ~ and then leave the site in a forward direction.

The applicant is proposing to provide four carparking spaces on site which is
in excess of minimum carparking requirements of both the relevant
superseded Noosa Plan and the current Noosa Plan. The Manager of Land
Use and Senior Planning officers from Council have advised at an Industry
Working Group meeting, that the provision of two double garages on site for
duplex dwellings would be acceptable. Further staff advised that they had
been accepting such a provision on a regular basis under The Noosa Plan.

However it is noted that the identification of this issue is considered to be
unreasonabie and irrelevant to the current application. In this regard Council
staff are reminded that the application merely seeks as assessment against
the current conditions of Preliminary Approval 2004/4077. This approval
allowed for the provision of a visitor carparking space within the on-site
double garages, with the only issues of concern identified in Condition 3 of
the Decision Notice.

 

ALTUM CONSTRUCTIONS
PO Box 2301 Noosa Heads 4567
Ph: 07 5448 2967 Fax: 07 5448 2417
ABN 70123 691 556 BSA Lic. 1114017
Full text of the other 4 pages

Page 2

Nonetheless, it is noted that the proposal meets Specific Outcome 17 which
states:

017 Garages, carport structures and vehicle manoeuvring areas are designed and
sited to-

a) provide for resident and visitor parking;

Resident and visitor parking is proposed to be provided in the form of
a double garage for each unit.

b) visually integrate with the building and to not dominate the street front;
The location of the carparking and orientation of the building ensures
that the garages are unable to be directly viewed from the street
frontage.

c) allow opportunity for landscaping to screen vehicle parking and
manoeuvring areas;

The 16 metre building setbacks allow ample area for dense
landscaping to be established between the road reserve and the
vehicle parking areas.

d) minimise the number of driveway accesses;
One driveway is proposed as part of the development application.
e) allow safe and efficient access to and egress from the premises.

The proposed driveway locations allow safe and efficient access to the
proposed dwelling units.

This concludes our response to the information request. In accordance with the
relevant provisions of the Integrated Planning Act, please commence the decision
period of the assessment process.

Yours sincerely

jTyly

Alex Rigby

’ “.LTUM

Mobile: 0415 129 550

Ph: 07 5448 2967 Fax: 07,5448 2417
Address: PO Box 2301 Noosa Heads 4567
ABN 70 123 691 556 BSA Lic, 1114017

Page 3

 

Bey wets we ES po mh BG pie weed \
C C) Ze NS sisAjouy apap Bupwiny SOLO LE sq £10 QN Ald SNOLLINALSNOD WNITY TO 'HOV3d NVIDR3d ‘1S 13893 ¢

Sp St!YU310 Sysods

1 1 Ul ev 8 002'1 21025

JONIAISIY XTMNG GISOdOad

 

002-1 0682 SV Jed se ajyejdwa}
BPIYD9A GE 40) afoul Burin

a
——_
f : 2
a
oo
\ 4:
a ;
\ = :
a ‘
\ \ oe
Le
\ \ a
. oe
\ a a
Se a
—_ — ~ SI OoS
NO -
eons
~ XN
SY ~
~ N
me > N *
XS : ~
>
x So
> ~
> ~
re aal

 

araiyaa (ajquaciad WNg'66) 66d QS

(  3anssiva

SHOIEG panss| —_ajog_Aay )

Page 4

 

 

 

 

ALD

8 EGRET STREET
PERIGIAN BEACH

FOR

ALTUM CONSTRUCTIONS

 

QLD

GENERAL NOTES

Water Supply and Scnitary Drainage has been designed and shail be constructed in
accordance with the Q'Id Standard Sewerage Law, Q'td Standard Water Supply Low,
the National Plumbing and Drainage Code AS 3500., all relevant Australian Standards,
and the requirements of the Local Authority.

These Drawings are diagrammatic only and shall be read in conjunction with all relevant
Architectural and other consultants drawings and specifications and other written
instructions that may be issued during the course of the contract.

Any discrepancies shall be referred to the supervising officer for decision before
proceeding with the work,

Contractor shall verify all fixture iocations, invert levels, surface levels, and

cover to pipes are correct and obtainable prior to commencement of the work.

The exact location of existing, ond proposed services, shall be verified with

the relevant Authority, or other trades as applicable.

Fire stop collars to be used on all plastic pipework penetrating fire resistant
construction.

SANITARY DRAINAGE

Underground pipework shali be 100 dia. PVC DWV, min grade 1:60 U.N.O.
Suspended Pipework shall be PVC class DWV.

Trade waste pipework to grease trap suspended shall be "Coesprene” or
HDPE. Underground shal! be vitreous clay or HDPE.

Trade waste pipework to oil separator shall be HDPE, or Vitreous clay with
“Nitrile” rubber rings.

CLeanouts or inspection openings brought to surface in paved or concrete
areas, or within buildings to have brass caps.

STORMWATER DRAINAGE

Underground pipework shall be 100 dia PVC class SW min grade 1:100 U.N.O.
Downpipes shall be 100 Dia PVC class SW.

Rainwater outlets (RWO) and planter outlets (PO) shall be "Gatic Wade” or simitar,
with membrane clamp where required.

WATER SUPPLY

Pipework shall be according to AS4020 for example ABS (acrylonitrite
stytrene), PP (Poly propylene) or PE (Polyethylene) or copper UNO,

Water supply pipework shall be 20 dia UNO.

Exception: one fitting only may be 15 dia. max. fength 3000 mm.

Hot water pipework shall lagged.

Hot water recirculating lines to be insulated with 20mm “Armaflex’ or similar.
Provide tempering valves on hot water to personal hygiene fixtures.
Underground copper pipework shall be "Kemlagged” or otherwise protected.
Underground pipework not under concrete slab may be polypipe class PN20.
one size larger than shown.

Exposed pipework in amenities areas, sha!l be chrome plated,

Where water meters are installed within tennancies, provide remote readout
adjacent to Electrical meters, or in a position as indicated by the Architect.

BACKFLOW PREVENTION
Provide hose connection vacuum breakers to all hose cocks
Provide RPZD to any irrigation connections.

COVERS & FRAMES

Covers subject to vehicular traffic to be 535 dia, cast iron, medium duty UNO.
Covers in grassed or cone. creas to be 535 dia. cast iron, concrete infill light duty.
Covers in paved areas to be 600 sq. Infill to match paving pattern.

Covers in tiled areas to be as for paved areas with brass edging.

Concrete infill covers to be stamped "SWD" or "SEW" as appropriate.

Covers & Frames to be "Faston” or equal approved.

GRATINGS

Gratings for storm water to be “faston, Gatic” or approved equal.
Duty to motch manufacturers recommendatians for loading condition.
Trench grate to be transverse bar.

Floor waste grates to be chrome plated brass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND
Non potable water ® Diameter
Existing water €.0.8. Cleanout to surface
Existing sewer Cd Capped junction
Existing storm water cv Conroi valve
Existing house drain cs ceoners, sink
i i cw o later
vont pe nose DAP Duct access panel
Cold Water Ocv Double check valve
Een Eccentric Enlarger
Hot water Elev Dge Evevcted Drainage
Storm Water Drainage Ent Enlarger
Fire FC False ceiling
agi Agi Drain FH Fire Hydront
FHR Fire hose reel
. FFL Finished floor level
Cold Water Riser FU Fixture units
Down Pipe GIT Grease Interceptor trap
5 GP Gully pit
) Stack CMH Gully Man Hote
Vent Pipe gv Gate valve
@) o HW Hot water
GQ) Group vent HCB House connection branch
Educt vent HD House drain
@®) o HL High level
@ Induct vent Ic ingpection Chamber
Hot water riser re Invert Level
° i io Inspection opening
Fire Dropper ios inspection Opening to Surface
(8) o Fire Riser K&C Kerb & Channel
CB) ° ; MH Manhole
(6) Non potable riser NRV Non return valve
a ( » _— PB Path box
woter meter PLV Pressure fimiting vaive
% PO Planter outiet
v falve Cock RPB Real Property Boundary
— ne ose Coc RPD Real Property description
—_— een £ tri \ RPZD Reduce Pressure Zone device
ecentric enlarger Rwo Rain water outlet
eae en Enlorger RWH Rain woter head
SD Sanitary Drcinage
E) ORG Overflow Relief Gully SL Surface Level
S Square
— WC Water okt Safe Tray
Closet SWD Storm water drain
. t/td Trapped Tundish
(45 sk Sink TG Test gate
td Tundish
UT Laundry tub Tous Trench grate transverse bor
TOU) Trench grate longitudinal bar
wm Washing T.MV, Thermostatic mixing valve
Machine TV Tempering valve
Fwo Floor Waste u/g Underground
gully u/s Under slab
. u.n.o. Unless noted otherwise
Bn Basin WS Water supply

 

 

 

 

Shower

HWS Hot water system

FHR Fire Hose Reel C)

cs Cleaners Sk

(J
e
S
(7 }} bth Bath S<]
——— Shr
Et
CH

 

 

 

 

(h SIRS

 

 

 

 

 

 

 

Site 1083.8m?
Roof 257.8m ?
Driveway 274.1m?
Landscape 551.9m?
New impervious 531.9m?

 

CATCHMENT AREAS

 

Note:

All kitchen, laundry & bathroom fittings and toilets
to comply with the AAA Water Conservation Rating
System as defined by AS/NZS6400.

Provide flow restrictor valves where necessary

to taps and shower roses. The flow shall not
exceed a maximum of 9L/min

  

 
  

Provide.-.a°@80 sub—soil drain at
the base of retaining wall, as per
structural engineers Specification
and join to GP6 with #100 PVC.

      
 
 
 
 
   
 
   
 
 

Sif

   

Provide a #80 sub-soil drain at
the base of retaining wall, as per
structural engineers Specification
“and join to GP6 with #100 PVC.

 
   

 

  

TG

    
  

2
&
os
5
Q
a
a
aa

 

 

  

   

 
     

ae

Note:

Do not scale from these drawings.
Do not rely on these drawings for
alignment and levels of all existing
infrastructure.

It is the obligation of the contractor
and/or plumbing contractor to survey
all existing services prior to
construction

 

LOCALITY PLAN

 

Provide a #80 sub-—soil drain at
the base of retaining wall, as per
structural engineers Specification
and join to GP6 with 100 PVC.

 

| daybed

media f

 

 

  

teach shower

 

  
 
 

  
 
   
    

fayhe

 

 

BASEMENT STORMWATER DRAINAGE.

 

7” ~CP6
~
”
”
”
7

Provide a 980 sub-soil drain at “eo

the base of retaining wall, as per ”

structural engineers Specification “ ne

and join to GP6 with #100 PVC. ae

Lot 293

DRAWINGS
1901-1 -
1901-2 -

Pollution Control

iaqnagemen

1. To be responsibility of Managernent

2. To list all in flow filtering devices like leaf eaters
at DP’s and other filters

3. To keep and maintain a log of cleaning

4. To clean devices including first flush storage tank
—as to manufactures specification

on PLOT—93112

GENERAL NOTES & LEGEND
SITE STORMWATER DRAINAGE

Plan (PCMP

 

—minimum quarterly, but monthly in rainy season
—after each major rainfall event

5. To inspect and clean tanks minimum once yearly

6. To install and maintain pump and fixtures for
reuse/watering/irrigation as to manufactures specification

X

AERIAL PHOTO

  

   

COUTESY NOOSA SHIRE COUNCIL

 

Amd Description Dote

 

 

 

 

—r-

 

 

 

 

 

 

 

 

 

 

 

 

Issue LC Notes Date
For Development Aosrowa| x betes
For Building Approval
For Tender | T
For Construction
jAs_Constructed

 

 

 

contact: Reinhold Koenning MigAust RPEQ No 7023
PO Box 1176
Buddina QLD 4575
7 email: [email protected]
www.conhyd.com

PH: 5444 8645
FX: 5444 8224
CUENT :

s ALTUM CONSTRUCTIONS

 

ARCHITECT :
SPARKS ARCHITECTS

NEW DUPLEX RESIDENCE
8 EGRET STREET
PERIGIAN BEACH QLD

DRAWING TITLE:

 

 

~|

PROJECT:

 

i GENERAL NOTES, LEGEND
’ & STORM WATER DRAINAGE

 

 

Design| RK [Checked [pete [20-3-08 | Dwg. No.
1 of 2 | 1901-1

Lot 293 on pilot 93112

SCALE : 1:100 ON At ULN.O.

 

 

RPD:—

 

Page 5

 

ve <3,

2°

hi ‘0

24.0 7 4bon
a PON!

  
 
  
 
 
 
 
  
 
  
 
   

 

  

15,000It Tank :
see hote—5 450sq!.:.

 

 

22.0
NS
MN .
oN .
No.

  
   
 

 

NOTES:

1

Provide second stage treatment, first flush and
silt trap charnber, 61050 concrete as per detail.

Provide First stage treatment, baffled Gross
Pollutant trap (BGPT) Type; "FOX" or

>

 

 
  
  
   
 
  
 

 
  
 
  

Concrete ring

 

Precast
components

-

“CLEARMATE” with 300mm riser, as per detail.

Provide a 450mm wide trafficable grated drain

and discharge to BGPT above strainer basket.

Provide a new 1050 concrete standard SW

manhole over existing SW and connect a 6300

RCP. For details refer to Sunshine Coast

Regional Council stondard drawings.

Provide a stormwater harvesting tank with a

minimum volume of 15,000 litres.

600mm DIA cast iron cover
and frame. Refer Note 11

1050 nom

C>

Top of access chamber
100 above finish surface but
flush with pavements.

i

max
350

 
   

2000 max.

 

  

MH-1/1
SL15.800
1L14.600
See note—1

 
 
  
  

 
   

 

of i
1H 4150 ovat
A trom cer.

 

 
 
 
  

 
   

#300 FRC

 

BGPT SL15.900
OUTLET: IL15.300
See note-2

 
  
 
 

 

 

 

 

 

 

 

 
 
 

Detention and infiltration
chamber, standard, concrete
Precast, 91050 internal, depth
1350, with heavy duty lid

$L15.800 |
VY

=p

 

 

LT 4 9150
7 O

$225 21050 ey] | #300 RCP

 

 

 

 

1L15.000

\ 7 IL14.900
r / to SW Manhole \V/

IL14.600

 

 

 

 

 

 

 

 

 

 

 

 

plo Geotextile

Vv st eee
5 HI

| IQ

I | — 1L14.300 |S
(TS

%225 perforated PVC. Coarse gravel

wrapped in geotextile min size 80mm

STORMWATER ON SITE SILT TRAP, INFILTRATION & OVERFLOW SYSTEM SCALE: NTS

GROUND FLOOR & SITE
STORMWATER DRAINAGE

 

 

FOX BAFFLED GROSS POLLUTANT
COLLECTION TRAP DETAIL WITH RISER
ATTACHED TO 450mm_ TRENCH GRATE
NTS

Sw. Sw- sv
Levels subject to survey.

 

Saw cut at existing

Pavement refer pavement

Project documentation
for detail

  
   

50mm Asphaltic paving

   
       
 
  
  
  

Rot
S

 

    
  
 
 
  

Existing
pavement

     

 
 

Pavement Deep
lift asphaltic concrete

No fines concrete backfill
(8 parts 10mm NOM size
aggregcte to 1 part cement)

Coarse or

36
fine bedding

EXCAVATION, BEDDING AND BACKFILLING
OF STORMWATER DRAINAGE PIPES
SCALE 1:20

 

Notes:
1. Selected backfill in all cases shall be carried through to the wings and
continued 300 thick for the length and height of wings.
2. Bedding compaction (Compacted selected fill/sand bedding)
Cohesive material — 95% standard compaction
Non-cohesive material — density indes of 7Omin, refer AS1289.E5.1
Sand — compact by flooding and use of vibrators.
3. Backfill compaction
Compacted gravel (300mm) layer under road pavement 95% standard compaction
Compacted ordinary fili/CBR15 Gravel 90% standard compaction — below 300mm zone.
Compacted backfill — ot footpaths/private property 90% standard compaction.
MAX. densities determined by standard compaction tests to AS1289.5.1.1.
4. Type U & Type H1 to conform to AS3725.
5. Dimension A can be reduced to 150min for non mechanical
compaction of backfill.

   
 

DETAIL MH 1/2

  

 

 

 

 

Description Date

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

—

| |
L

—

Issue Notes Date

For Development Approval] x [ 20-3-08
For Building Approval |
For Tender
For Construction |
As Constructed t |

 

 

 

 
 

Construction Hydraulic
Bullding Service Engineers :

     

 

-

CLIENT : 4

contact: Reinhold Koenning MigAust RPEQ No wa |
PO Box 1176
Buddina QLD 4575

email: [email protected] PH: 5444 8645
www.conhyd.com FX: 5444 8224

ALTUM CONSTRUCTIONS

 

ARCHITECT :

 

\. SPARKS ARCHITECTS
PROJECT:

NEW DUPLEX RESIDENCE
8 EGRET STREET
PERIGIAN BEACH QLD

 

 

 

 

DRAWING TITLE:
SITE STORMWATER
DRAINAGE
Design| RK [checked | [pete [20-3-08 | Dwg. No.
SCALE : 1:100 on Ar uno] 2 oF 2 | 1901-2

 

RPD:— Lot 293 on plot 93112

 

 

Used in these records

About this file

File size
756 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0170 - Response to Information Request [As Published].pdf · 756 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.