Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

Email Response Letter MCU18.0048-signed · MCU18/0048

Attached to the e-mail Response to information request - MCU18/0048.

of 1

Text shows just the words. Original shows the document exactly as it was published.

                                                                                            Issue 3
26th April 2018                                                                             The proposed garage (Class 10A portion) has been adjusted to be 400mm from side
                                                                                            boundary and is clad in stone, a natural product to blend in with surroundings and
Noosa Council                                                                               curved at front to reduce impacts. However the garage siting is QDC compliant, i.e.
                                                                                            not more than 3.50m average height above natural ground surface and less than
Attention:    Lisa Pienaar - Development Planner
                                                                                            9.0m aggregate length within 1.50m of side boundary, and more than 6.0m from
Via email:        [email protected]                                                     front boundary, therefore meeting Schedule 1—Minimum boundary setbacks for
                                                                                            buildings and other structures
RE:        RFI RESPONSE MCU 18/0048
           AT 7 Aarkoon Crescent, SUNSHINE BEACH QLD 4567                                   Issue 4
           Lot 780 on RP 48111                                                              Driveway access & transitions.
           SBA file 18-0387                                                                 Refer SCG driveway plan and long section which demonstrates via plan and
                                                                                            longitudinal section that transitions can be achieved to meet AS2890.1 and provides
Dear Lisa,                                                                                  the requested footpath zone behind the kerb as discussed with Engineering Officer
                                                                                            Mark Lewis, including the minimum required earthworks for cuts in road reserve
Further to Councils RFI letter dated 05 April 2018, and subsequent discussions,             with no retaining for driveway proposed.
please find attached:

      1.   Amended Plans by Aboda MCU issue 2 with cut fill plan                            Issue 5
      2.   SCG Consulting Engineers stormwater management plan 28045-SW1                    Stormwater management addressed by SCG stormwater management plan which
                                                                                            includes side entry pits to allow overland flow to be maintained from the rear.
      3.   SCG Consulting Engineers slope stability report 28045(SL) & 20845(S)
      4.   SCG consulting Engineers driveway plan, section & details 28045–DR1

The plans have been updated with the garage 400mm relocated off the side                    We trust this information is sufficient for council to complete assessment and issue
boundary (for stormwater pipe).                                                             MCU with reasonable & relevant conditions. We request council provide a copy of
                                                                                            draft conditions for review before issuing approval.
Issue 1
Filling beyond 1.0m past house footprint.
Refer WD104 which shows site cuts, the filing is to occur for the planter box (approx       Yours Faithfully
1500mm high containing 38m3) in the North East corner to create a completed                 SUNCOAST BUILDING APPROVALS
greenery patch where the vegetation is higher than an allowed 2.0m fence at time of
completion; TOW is RL 34.250, with NGL front south west corner approx RL32.75.
Filling also for planting / turf beside pool at RL 36.935 (up to 1.40m) and stair landing
at RL35.910 (up to 1.80m).
                                                                                            Zane Russell
                                                                                            Building Certifier
Issue 2                                                                                     J:\data\Personal Folders\Zane\000 Projects\7 Arakoon Cr SUNSHINE BEACH 18-0387\Email Response Letter MCU18.0048.doc
Building Height not over 8.0m
See MCU 2 plan set which used the 8.0m height overlay program to demonstrate
that the dwelling did not protrude through the 8.0m ceiling above the NGL. Refer to
heights nominated on northern elevation and sections A & B demonstrating the
8.0m above the surveyor interpolated ground level and finished ground level has not
been exceeded.

Used in these records

About this file

File size
308 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Email Response Letter MCU18.0048-signed.pdf · 308 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.